Description Material 1 Bracket Steel strip 2 Cross recessed round head screw Steel wire 3 Clasp Steel strip 8 Cassette 9 Seal NBR 10 O-ring NBR 11 O-ring NBR 12 Bonnet A POM 13 Bonnet B POM 14 Gear PPS 15 Indicator gear POM 16 Clip Stainless steel 1 The AS3002FS-11, AS4002FS-11, AS4002FS-13 are made of stainless steel. 9 Related Equipment Holder for Speed Controller TMH Series Specifications
15 11 15 14 20 16 25 22 32 22 32 28 40 28 40 33 50 33 50 43 29 43 29 28 19 28 19 18 11 18 11 12 7 8 5 5 3 3.8 2.5 1.3 1 0.7 VNB1-6A VNB1-8A VNB1-10A VNB24-10A VNB2-10A VNB24-15A VNB2-15A VNB34-20A VNB3-20A VNB44-25A VNB4-25A VNB54-32A VNB5-32A VNB54-32F VNB5-32F VNB64-40A VNB6-40A VNB64-40F VNB6-40F VNB74-50A VNB7-50A VNB74-50F VNB7-50F 1 8 1 4 770 520 770 520 500 330 500 330 320 210 320
RQ MU DSpecifications Dimensions -X 11 3.5 The specifications are the same as those for the standard double acting type.
Applicable Auto Switch/Refer to page 9-15-11 for further information on auto switches.
S 0 0 Delivery pressure Bonnet option Delivery pressure 1 to 30 psig (0.007 to 0.2 MPa) 2 to 60 psig (0.014 to 0.4 MPa) 2 to 100 psig (0.014 to 0.7 MPa) 5 to 150 psig (0.034 to 1.0 MPa) Code Code Bonnet Standard Panel installation 4) 02 06 10 15 No code P Connections (Inletq, Outletw) 4) Panel mounting hole: dia. 1.42 inch (36.1 mm).
5.5 58 8.5 1.5 8.5 11 M3 x 0.5 7.5 M2.5 x 0.45 16 (12 x 2) 33 24.5 6 6.5 2 18 11 5.5 64 9 3 9 11 M4 x 0.7 10 M3 x 0.5 Bore size OA OB OL P PD PE PW Q R S T U VA WA X YY YL Z 12 (10 x 2) 3.4 6.5 2.5 M3 x 0.5 6 16 18.5 8 26 14 49.5 39 52 10.2 23 M4 x 0.7 6 4.2 16 (12 x 2) 3.4 6.5 2 M3 x 0.5 6.5 16 18.5 8 28 14 53 42 57 10.2 24 M4 x 0.7 6 4.3 6 JMGP Series Bore Size 20 (16 x 2) to 40 (32 x
Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Abnormal low tank fluid level 1 Low tank fluid level 2 None 3 None 4 None 5 Fan failure Alarm flag 1 6 None 7 None 8 Abnormal rise of circulating fluid temperature 9 Circulating fluid temperature rise 10 Circulating fluid temperature drop 11 TEMP READY
Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 CH1 abnormal low tank fluid level 1 CH1 low tank fluid level 2 CH2 Abnormal low tank fluid level 3 CH2 low tank fluid level 4 Reservation 5 Fan failure Alarm flag 1 6 Reservation 7 Reservation 8 CH1 abnormal rise of circulating fluid temperature 9
D1 D2 L1 L2 M A 5 32 3 16 3 16 1 4 1 4 5 16 5 16 3 8 3 8 1 2 1 2 KQ2L01-03 KQ2L01-05 KQ2L03-05 KQ2L03-07 KQ2L05-07 KQ2L05-09 KQ2L07-09 KQ2L07-11 KQ2L09-11 KQ2L09-13 KQ2L11-13 9.6 7 10 10 8 3 7 6 3 8 11 12 17 17 30 25 17 17.5 25 13.5 2.2 2.5 3 2.5 1 8 15.5 33 33.5 26 34.5 35.5 36.5 37.5 40.5 41.5 43 21.5 22.5 14.5 23.5 23 24.5 23.5 5 32 16 18 10.4 3 16 3.5 16.5 19.5 10 11.4 1 4 4.6 17 20.5
YU-03 T1 B 2-D through 2-O counterbore (mm) Bore size (mm) B D E J M O Part No. 12 7 25 9 34 11.5 depth 7.5 YB-03 32, 40 12 9 32 11 42 14.5 depth 8.5 YB-05 50, 63 Joint Weight (g) Bore size (mm) T1 RS T2 V W Part No. K ( across flats) H (With locking) 80 9 6.5 10 18 50 YB-03 32, 40 120 11 6.5 12 22 60 YB-05 50, 63 d2 d1 L UT C UA (mm) UA C d1 d2 H k L UT Weight (g) 25 Part No.
SY SYJ Specifications Max. operating pressure Min. operating pressure SX 0.8MPa 0.15MPa 5 to 50C 2.7mm 2(0.15) 180CPM VVQ1000-FPG-02 1set VQ1000-FPG-C6M5-D 2 pcs.
M1 Weight (g) 4 6 6 8 6 8 10 8 10 8 10 10 12 Applicable tubing O.D. d T H D1 D2 L1 L2 L3 Model AS121-M5-F04 AS121-M5-F06 AS221-01-F06S AS221-01-F08S AS221-02-F06S AS221-02-F08S AS221-02-F10S AS321-02-F08S AS321-02-F10S AS321-03-F08S AS321-03-F10S AS421-04-F10S AS421-04-F12S 16 17 17 18.5 17 18.5 21 18.5 21 18.5 21 21 22 13 13 34 31 54 50 52 86 81 93 88 154 146 21 21.5 25.5 26 M5 x 0.8 28.3
Communication connector D-sub 9 pin (socket) Holding screw: M2.6 6 Contact a for output cutoff alarm (open when alarm occurs) 7 Common for output cutoff alarm 9 15 10 11 12 13 14 Pin no.
Applicable model D5 L9 L10 L11 L12 L13 L14 L15 L16 L17 t1 AS-10L AS1002F3.4 14.8 18.3 11 27.5 19.5 3.4 4.9 7.3 12 1 AS-20L AS2002F 15.6 19.6 12.6 29 21 1.2 AS-25L AS2052F 4.5 19.6 24.6 17 38 28 4.5 6.5 9.5 15.5 AS-30L AS3002F 24.8 29.8 22 43 33 1.4 AS-40L AS4002F 25.7 30.7 28 49 39 3.5 18.2 23.2 11 3.5 18 11.3 1.6 AS-20D AS2002F 18.6 23.6 12.6 19.6 AS-25D AS2052F 4.5 4.4 22 27 17 4.4 25.8
SET-ON 10 Start readiness signal CN2 24V DC + COM 1 COM 11 NO. 0 Indicates operation in progress when ON. ON when program is being executed and when returning to the home position. 2 BUSY 11 Operating signal NO. 1 12 NO. 2 3 <1> When this signal is OFF, an alarm is being generated for the actuator/controller.
L d m t D d H B C C type 8 for shaft C type 10 for shaft C type 10 for shaft C type 14 for shaft 21 25.6 41.6 50.6 7.6 9.6 9.6 13.4 16.2 20.2 36.2 44.2 1.5 1.55 1.55 2.05 0.9 1.15 1.15 1.15 20 25 32, 40 50 M8 x 1.25 M10 x 1.25 M14 x 1.5 M18 x 1.5 5 6 8 11 13 17 22 27 15.0 19.6 25.4 31.2 IY-G02 IY-G03 IY-G04 IY-G05 NT-02 NT-03 NT-04 NT-05 8 10 10 14 0.040 0.076 0.040 0.076 0.040 0.076 0.050
(Default) Spare (SW2-2) Rotary axis setting switch (SW1) Description Display 0 Axis No.1 01 1 Axis No.2 02 2 Axis No.3 03 3 Axis No.4 04 4 Axis No.5 05 5 Axis No.6 06 6 Axis No.7 07 Down 7 Axis No.8 08 (Be sure to set to the 8 Axis No.9 09 "Down" position.) 9 Axis No.10 10 A Axis No.11 11 B Axis No.12 12 C Axis No.13 13 D Axis No.14 14 E Axis No.15 15 F Axis No.16 16 -12- 5.
Pressure gauge Lubrication Not required ITV Installation Horizontal AN200-02 AN400-04 AN300-03 AN300-03 AN400-04 Silencer Pressure adjustable mechanism Relieving type IC How to Order Pressure VBA Pressure increase ratio 2.0 MPa 1 Twice 4 times 0 1 VE Pressure setting Handle operated type 1 Port size VBA1110-02 VY1 Body size Port size Rc 1/4 Symbol 02 1/4 1 VBA1-02 G VBA 1 1 02 1 0 GN Series
PA13 Selection of command input pulse form Pulse train form Forward rotation command Reverse rotation command Setting Forward rotation pulse train Reverse rotation pulse train PP 00 NP Positive logic PP Signed pulse train 01 NP L H PP A-phase pulse train B-phase pulse train 02 NP PP Forward rotation pulse train Reverse rotation pulse train 10 NP PP Negative logic Signed pulse train 11 L H
IP config Next 5 Install IP config 6 IP config Installshield Wiazrd Completed Finish IP config 3 23 - 4)IP config 711IP config No. 7 (1)(3)IP config IP config GW Scan IP config GW (1) (2) 8 GW IP config MAC ) MAC =00-23-C6-02-F0 GW 9 IP addressSubnet maskIP Set ) IP =192.168.250.2 =255.255.255.0 10 GW DHCP OFF() DHCP DHCP DHCP ON()Set *GW DHCP ON() 11 IP DHCP ON/OFF