[F80] Power saving mode completed In power saving mode, when buttons are pressed the display is normal, but if no buttons are pressed for 30 seconds, it will revert to power saving mode.

If the sub display is switched during the arbitrary display setting, the display will be returned to the arbitrary display 30 seconds later. (The default setting does not include arbitrary display.) NOTE If the error cannot be reset after the above measures are taken, or errors other than above are displayed, please contact SMC.

They are all important notes for safety and must be followed in addition to International standards (ISO/IEC) and other safety regulations. ( ) For compound 101 kPa ( ) For low pressure 100 kPa ( ) For positive 1 MPa ( ) For vacuum -101 kPa [Default setting] ( ) For low differential 2 kPa ( ) For positive 500 kPa N.C.

22 34.6 48.9 20.9 21.7 12 1/2" 22 101 Reference dimensions of M5 x 0.8, R threads after installation.

NPN open collector 1 output w/analog output, 200 degrees adjustment 3 m 30 19 5 m 50 PNP open collector 1 output w/o analog output, 200 degrees adjustment 55 774 Compact Pressure Switch Series ZSE1/ISE1 Specifications ZSE1 For vacuum 0 to 101 kPa 10 to 0 kPa ISE1L For low pressure 0 to 100 kPa 10 to 0 kPa ISE1 For high pressure 0 to 1 MPa 0.1 to 0 MPa 1.5 MPa Air/Non-corrosive, non-flammable

(Ex.) 1. 2. 3. 4. 13-1 IDFA Series 13 1 IDX-OM-W017 13 V 13-2 ON0.5 OFF30 IDFA4E15E1-23-V IDF-S0198 1.6MPa AC230V10% (50Hz) ON 0.5sec OFF 30 13-3 1) 2) 3) 4) ON OFF 4 6 2 3 8 4 2 1 10 0.5 5 0.5 ON:SEC OFF:MIN 13-2 IDFA Series 13 2 IDX-OM-W017 14 14 14-1 / IDFA Series 14-1 14 1 C2019/11 D2020/10 E2021/5 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: +

Leave an interval of a minimum of 15 ms (recommendation is 30 ms) between input signals and maintain the state of the signal for a minimum of 15 ms (recommendation is 30 ms), because PLC processing delays and controller scanning delays can occur. 12.4 Controller input signal response Signal timing Check the timing of the signal from the PLC to the controller. time When power is applied,

66.5 46 76 24 1/4, 3/8 VCB31 M5 23 25 32 15 13.5 36.5 86 50 8 30 104 68 71 101 71 46 80 24 1/2 M5 23 22.5 36 17 11 41 90 45 8 22 107 70 74.5 103 74.5 48 84 26 1/4, 3/8 VCB41 M5 23 25 36 17 13.5 41 94 50 8 30 111.5 70 78.5 103 78.5 48 88 26 1/2 M5 28.2 30 36 17 17.5 41 102 60 8 35 119 70 86.5 103 86.5 48 96 26 3/4 4 Series VCB Model Selection VCB (for heated water) 2 port solenoid valve Class

Vacuum pump Conditions: Vacuum pump exhaust speed: 2500 l/min VAC side pressure: 101 kPa (At initial setting) Flow-rate Characteristics (Representative Value) Pressure Characteristics (Representative Value) IRV10-C08 (One-touch fitting 8) IRV10 53.0 0 10 53.5 SET side pressure (kPa) 20 54.0 Set pressure (kPa) 30 54.5 40 55.0 50 55.5 60 56.0 70 Set point 56.5 80 57.0 90 0 20 40 60 80 100 120

Description Applicable model ITV10 P398010-600 Flat bracket assembly (including mounting screws) ITV30 ITV20, 30 P398020-600 ITV10 P398010-601 L-bracket assembly (including mounting screws) ITV20, 30 P398020-601 [Cable connector] 243 Part No.

(1 bit) 145 20 10 85 15 10 Reading of internal parameters (7 words) 270 40 15 150 25 10 Operation mode selection 165 25 10 95 15 10 Commands for virtual I/O operation by serial communication 195 30 15 110 20 10 Reading of alarm history (4 words) 215 30 15 120 20 10 Clearing of alarm history 245 35 15 135 20 10 Confirmation of communication connection 165 25 10 95 15 10 The communication

Max. voltage (with no load): 30 Vrms (42.4 V peak) or less Max. current: (1) 8 A or less (including shorts), and (2) When controlled by a circuit protector (fuse, etc.) with the following rating Max. current rating 5.0 100 Peak voltage value No-load voltage (V peak) 0 to 20 [V] Over 20 [V] to 30 [V] 2) A circuit (class 2 circuit) with maximum 30 Vrms (42.4 V peak) or less, and a power supply

Refer to manifold ordering. 24 23 22 21 20 19 18 17 Terminal no. 28AWG 16 15 6 14 13 Red 12 11 10 9 8 7 26 2 25 1 30 (20P) 37.5 (26P) Connector terminal number 6 5 4 3 2 1 Triangle mark indicator position <26P> <20P> (15.6) Terminal no. Terminal no.

The time between two restarts of the outputs is too short the time interval must be at least 30 seconds. 0x01F5 None 501dez The process image for parameter values must contain valid values. The SI unit needs a HW reset when the process image contains new parameter values.

MPa 100 90 100 90 ZQ Vacuum pressure (kPa) Vacuum pressure (kPa) 80 80 70 70 ZF 60 60 50 50 ZP 40 40 30 30 ZCU 20 20 10 10 AMJ 0 0 10 20 30 40 50 60 70 80 90 100 110 120 20 60 100 140 180 220 260 300 130 Suction flow rate (/min(ANR)) Suction flow rate (/min(ANR)) Misc.

Inclination from the vertical line should be less than 5. 3) Install one-touch fitting (width across flats: 17) to drain port (width across flats: 30) and the drain tube. 4) Connect the 2 electric cables coming out from the auto drain with the two electric cables from the dryer unit. Insert the drip-proof connector to the deepest part.

It shifts to the power-saving mode without button operation for 30 seconds. It is set to the normal mode (Power-saving mode is OFF.) when ex-factory. (Decimal points and operation indicator light (only when the switch output is turned ON.) blink in the power-saving mode.)

50% 70% 10% 30% 50% SY 150 300 Stroke (mm) 70% Stroke (mm) AS2201F -01-06 AS2200-01 AS2201F -01-08 AS2200-01 70% 100 SYJ 200 50 SX 100 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 10% 30% 50% 70% 50% 30% 10% 0 0 200 CM2 25 400 MB 40 150 300 Stroke (mm) Stroke

SW3 SW3 CM()SM() Table 10-29 SW3 Bit 1 Bit 2 OFF OFF SM (Safety mode) ON OFF OFF ON ON ON CM (Commissioning mode) SW3 DIP SMGSDML(Step7/TIA)/FDCML(PCWorx)Safe digital I/O (SM)CMSafe digital I/O (CM) 8.1.1 GSD CM1byte CM CM Table10-30, 10-31, 10-32 SM CM IO Table 10-30 COMNG_MODE I/O Byte 0 CN0-3 Zone M,Zone1-3 Byte 0 of COMNG_MODE Table 10-31 COMNG_MODE Bit 0 0 Zone M

-1No.JXC-OMT0001CN-C 1 . 30 2DIN . 30 4.5 . 31 (1) . 31 (2) . 32 (3) . 33 5. . 34 5.1 (IP ) . 34 5.2 PLC () . 35 TM . 36 TMEtherNet/IP 5.3 RSLogix5000 6. . 38 6.1 . 38 (1):C PWR . 38 (2):M PWR . 38 (3) : CI . 39 6.2 . 40 (1) . 40 (2) . 41 7.