Rated Pressure Range: -0.1 to 2 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount
Rated Pressure Range: -0.1 to 2 MPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual
Rated Pressure Range: -0.1 to 2 MPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation
Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, MUFFLER 2 PT, AIRLINE EQUIPMENT, AN SILENCER, KB, AN 2 INCH STANDARD (PT), 2.17455 lb, ModelEffective area mm2Sonic conductance C [dm3/(s?
Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, SILENCER, AIRLINE EQUIPMENT, AN SILENCER, CB, AN 1/8INCH, .02204 lb, ModelPort sizeMaterialSensor cableMassWith sensor cableWithout sensor cable01R
Stations: 02 (2 Stations), Systems, Port Combinations: A [Ejector System, ø8 (Common PV)], Exhaust: 2 (Individual Exhaust), SI unit prefix: S (SI unit for EX260 or EX500), SI Unit: A3N (EX500, Gateway decentralized system 2, 32 outputs, M12)
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: None, Operation Manual: K (Operation Manual, Calibration
/N.C.), 1st Selection Vacuum V Port: 6 (Vacuum, V Port: Ø6), 1st Selection Quantity: 2
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate
Function: 2 (2 Position Double), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: B (24VAC), Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: Non-locking Push Type, Port Size: 02 (1/4)
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: None, Operation Manual: T (w/o Operation Manual, Calibration Certificate
Nozzle Size: 2 (ø1.0), 1st Selection Supply Valve and Release Valve: K (N.C.
Stations: 02 (Stations), Wiring: L (Individual Wiring or None), Manifold Options: B (with DIN Rail Mounting Bracket), Exhaust: F (Individual Port Exhaust), Pressure Switch for Vacuum/Pressure Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: without Option, 1st Nominal Nozzle Size: 2
/N.C.), 1st Selection Vacuum V Port: 9 (Vacuum, V Port: Ø5/16), 1st Selection Quantity: 2
Function: 2 (2 Position Double), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 6 (12VDC), Lead Wire: DO (DIN Connector w/o Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, Port Size: 02 (1/4), Thread: T (NPTF)
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: B (Panel Mount Adapter)
/N.C.), 1st Selection Vacuum V Port: 7 (Vacuum, V Port: Ø1/4), 1st Selection Quantity: 2
Stations: 02 (Stations), Wiring: F (D-sub Connector), Manifold Options: D [with Common Release Pressure Supply (PD) Port], Exhaust: C (Complex Exhaust), Pressure Switch for Vacuum/Pressure Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, with Unit Selection Function), Leadwire: without Leadwire, Unit Options: EW (with Unit Options E & W), 1st Nominal Nozzle Size: 2
Stations: 02 (2 Stations), Piping: U (U Side: Open; D Side: Closed), Thread Type: N (NPT), Supply Unit Components: S (w/Flow Adj. Valve; Stop Valve: None), Return Unit Flow Range: 20 (2 to 16 L/min), Supply/Return Port Size: 04 (1/2)
Stations: 02 (2 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 40 (5 to 40 L/min), Return Unit Components: S (w/Flow Adj.