SMC Corporation of America
Elite Part Number Search
Search Results "RDLQB32-100M-B-M9PWSAPCS"

phase J A B C D A COM COM COM B 12 VDC GND F.G.

Piston rod deflection reduced Deflection of the piston rod has been reduced by increasing the precision of the bushing and piston rod, and reducing the tolerances. 6-13-2 6-13-3 3 ISO/VDMA Cylinder: Standard Type Double Acting with End of Stroke Cushioning Series CP95 32, 40, 50, 63, 80, 100 How to Order CP95S B 32 100 W Without auto switch CP95SD B 32 100 W S Z76 With auto switch Courtesy

Magnet Slide Bearing Felt Holder Ball bushing Piston seal Rod seal Gasket A Gasket B No. q w No. !

Normal output Reversed output P_1(P_2)=A-(A-B)/4 n_1(n_2)=B+(A-B)/4 A = Maximum pressure H_1(H_2)= (A-B)/2 H_1(H_2)= (A-B)/2 B = Minimum pressure If setting is not necessary press the and buttons simultaneously for 1 second or longer. -37No.PS-OMU0012-C [F 6] Fine adjustment of display value This function is to manually perform a fine adjustment of the displayed pressure value.

JIS B 8370: General rules for pneumatic equipment. JIS B 8361: General rules for hydraulic equipment. JIS B 9960-1: Safety of machinery Electrical equipment for machines.

JIS B 8370: General rules for pneumatic equipment. JIS B 8361: General rules for hydraulic equipment. JIS B 9960-1: Safety of machinery Electrical equipment for machines.

When pilot valve B is pushed, the air which was acting upon the switching valve is exhausted, and drive chamber B once again switches to a supply state. A continuous reciprocal motion is generated by this repetition. 1. When air enters drive chamber B, the fluid in pump chamber B is forced out, and at the same time Drive unit fluid is sucked into pump chamber A. 2.

A-phase pulse B-phase pulse 11 12 11 10 10 Count multiplier In rod extending direction, A-phase turns on first, then B-phase turns on with the delay of In rod retracting direction, B-phase turns on first, then A-phase turns on with the delay of approximately 90 phase difference. approximately 90 phase difference. Counter performs addition in and does subtraction in .

At this time, magnet B goes out of the movement range of auto switch B, causing auto switch B to turn OFF. Furthermore, the piston moves to the right, causing magnet A to enter the movement range of auto switch A. As a result, auto switch A turns ON.

Drive data value is wrong (048) B Input RESET Set the "speed" to the "pushing speed" or higher.

AMX-OM-Q014-B PRODUCT NAME Membrane Air Dryer MODEL / Series / Product Number IDG30A IDG50A IDG60LA,IDG60SA IDG75LA,IDG75SA IDG100LA,IDG100SA Contents 1. Safety Instructions 1 2. Installations and Operations 3 3. Maintenance and Checks 5 4. Specifications 6 1.

Normal output Reversed output P_1(P_2)=A-(A-B)/4 n_1(n_2)=B+(A-B)/4 A = Maximum pressure H_1(H_2)= (A-B)/2 H_1(H_2)= (A-B)/2 B = Minimum pressure If setting is not necessary press the UP and DOWN buttons simultaneously for 1 second or longer. -44No.PS-OMW0005-C [F 5] Auto-shift setting Auto-shift function can be selected.

Calculate the moment of inertia for A and B separately as shown in the figures on the right. A part B part Procedure Calculation Calculation example 1. Check the operating conditions, dimensions of attachment, etc. Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.

Model Model Model Port size R(PT) Effective area (mm2) Weight (g) Dimensions (mm) Weight Effective area Port size Model Dimensions (mm) R(PT) (mm2) (g) AN200-02 35 17 63 22 19 25 84 25 22 35 92 30 27 165 107 46 36 225 132 50 41 490 200 74 55 580 233 74 60 820 263 86 70 A B D A B D 1 4 1 4 AN202-02 35 16 64 22 19 33 84 28 24 47 95 34 24 AN300-03 60 3 8 AN302-03 60 3 8 AN402-04 90 1 2 AN400

(For details, refer to CAT.E501-B "Air Fittings and Tubing" pages 143 through 145.)

Note) Depths of mark Q1, Q2 indicate that the body(A)/(B) are penetrated respectively.

(Values at the initial period) Note 3) At rated voltage Flow Characteristics/Weight Flow characteristics 1 2 (P A) 2 3 (A R) 3 2 (R A) 2 1 (A P) Weight Valve model Grommet C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv VT317 VT317V (Vacuum spec. type) VT317E (Continuous duty type) 0.29 kg 2.4 0.26 0.62 2.6 0.34 0.67 2.8 0.25 0.67 2.5 0.37 0.66

Model Weight Weight (g) VFN2000N/Flow Characteristics Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B EA/EB) VFN2120N-5D-02F 260 400 C 3.48 3.48 b 0.25 0.25 Cv 0.85 0.85 C 4.57 4.57 b 0.17 0.17 Cv 1.06 1.06 VFN2220N-5D-02F 2 position Single solenoid Double solenoid How to Order VFN2 20 1 5 D N 02 F Z Thread type Solenoid Single solenoid Double solenoid 1 2 NAMUR Interface Rc (PT) G (PF

the External Pilot VEX1 3 3 B A M5 G 1.