Body Size: 40, Thread: N (NPT), Port Size: 04 (1/2), Mounting: None, Float Type Auto Drain: D (N.O.
Material: E (Aluminum Cover, SPCD Case, NBR Gasket/O-ring, Nylon/Fluororesin Seal), Element Length: A (ℓ250), Port Size: 04 (1/2 Rc), Element Type: M (Micromesh, Stainless Steel 304/Epoxy Material), Nominal Filtration Accuracy: 5 μm, Element Seal Material: N (NBR), Accessory: B (Bracket)
Body Size: 3, Set Pressure: 1 (1.5 to 58 psi [0.01 to 0.4 MPa]), Exhaust Direction: 0 (Bottom Exhaust), Thread: N (NPT), Port Size: 04 (1/2), Option: EB (PNP Open Collector, 1 Output), Semi-standard: Z (Name Plate & Pressure Gauge in Imperial Units: psi)
Material: C (Aluminum Cover, SPCD Case, NBR Gasket/O-ring, Nylon Seal), Element Length: A (ℓ250), Port Size: 04 (1/2 Rc), Element Type: B (Sintered Metal, Bronze Material), Nominal Filtration Accuracy: 2 μm, Element Seal Material: N (NBR)
Valve; w/Stop Valve), Return Unit Flow Range: 20 (2 to 16 L/min), Supply/Return Port Size: 04 (1/2)
Size: 50 (Body Ported), Operation: 1 (External Pilot Solenoid), Port Size: 04 (1/2), Thread: N (NPT), Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: None, Option: B (Bracket)
Function: 2 (2 Position, Double), Model: 0 (Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 1 (100 VAC, 50/60 Hz), Lead Wire: F (Plug-in), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 04 (1/2)
Base Mounted Wiring: 10 (Non Plug-in Individual Lead Wire Entry), Stations: 05 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 04 (1/2), Thread: T (NPTF)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: F (G), Port Size: 04 (1/2), Output Specification/Temperature Sensor: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: J (Instantaneous Flow: L/min, Accumulated Flow: L, Temperature: Â
Stations: 02 (2 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: P (w/o Flow Adj.
Type of Actuation: 2 (2 Position Double), Manifold Type: 40 (Base Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: M (M Plug Connector w/Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: U (Surge Suppressor w/Light Non-polar), Manual Override: Non-locking Push Style, A, B Port Size: 04 (Base Mounted Sub-plate 1/2), Thread: N (NPT)
Solenoid: No.1 Solenoid, Body Size: 5 (20A), Style: 0 (Energized Open/N.C.), Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 04 [1/2 (20A)], Thread: N (NPT), Voltage: 6 (12VDC), Lead Wire: D (DIN Connector), Surge Suppressor: S (Surge Suppressor)
Flow Switch Type: 5 (Remote Sensor Unit), Rated Flow Range: 04 (0.5~4L/min), Return Unit: None, Thread: N (NPT), Port Size: 03 (3/8), Flow Switch Output: 1T (Remote Sensor Unit; Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None, Temp. Analog 1 to 5 V; Temperature Sensor: Yes)
Model: LVH40 (Body Class 4, N.C.), Lever Operation: Non-locking, Self-reset, Port Size: 04 (1/2), Pilot Port Thread: Rc, Material: A (Body: SUS, Actuator Section: PP, Diaphragm: PTFE)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 04 (1/2), Output Specification: A (OUT1: NPN; OUT2: NPN), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: J (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °F), Bracket: None, Calibration Certificate: A (Calibration Certificate)
Rated Flow Range: 102 (10 to 1000 L/min), Thread Type: N (NPT), Port Size: 04 (1/2), Output Specifications: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: M (SI Unit Only)
Flow Switch Type: 5 (Remote Sensor Unit), Rated Flow Range: 20 (2~16L/min), Return Unit: None, Thread: N (NPT), Port Size: 04 (1/2), Flow Switch Output: 1T (Remote Sensor Unit; Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None, Temp. Analog 1 to 5 V; Temperature Sensor: Yes)
Compressor Output 15HP, (11kW)], Thread: Rc, Port Size: 04 (1/2), Accessory: B (Bracket)
Function: 2 (2 Position Double), Piping: 4 (Base Mounted), Exhaust: 4 (Base), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: M (M Plug Connector w/Lead Wire 300mm), Light/Surge Suppressor: U (With light/surge voltage suppressor (Non-polar type)), Manual Override: Non-locking Push Type, Port Size: 04 (1/2), Thread: N (NPT)
Function: 1 (2 Position Single), Body Option: 1 (Base Mounted Non Plug-in), Direct Manual Override: 1 (Direct Manual Override), Pilot: Internal Pilot, Voltage: 7 (240VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 04 (Sub-plate Plug-in