Flow Range: 20 (2~16 l/min), Thread: F (G thread), Port Size: 03 (3/8), Wiring Specification: N (w/o Lead Wire), Output Specification: 1 (Pulse Output + Analog Output (1~5V))
Flow Range: 20 (2~16 l/min), Thread: Rc, Port Size: 03 (3/8), Wiring Specification: N (w/o Lead Wire), Output Specification: 1 (Pulse Output + Analog Output (1~5V))
Flow Range: 04 (0.5~4 l/min), Thread: N (NPT Thread), Port Size: 03 (3/8), Wiring Specification: N (w/o Lead Wire), Output Specification: 1 (Pulse Output + Analog Output (1~5V))
Flow Range: 04 (0.5~4 l/min), Thread: F (G thread), Port Size: 03 (3/8), Wiring Specification: 3m Lead Wire w/Connector, Output Specification: 1 (Pulse Output + Analog Output (1~5V))
Flow Range: 04 (0.5~4 l/min), Thread: N (NPT Thread), Port Size: 03 (3/8), Wiring Specification: 3m Lead Wire w/Connector, Output Specification: 1 (Pulse Output + Analog Output (1~5V))
Flow Range: 20 (2~16 l/min), Thread: F (G thread), Port Size: 03 (3/8), Wiring Specification: 3m Lead Wire w/Connector, Output Specification: 1 (Pulse Output + Analog Output (1~5V))
Flow Range: 20 (2~16 l/min), Thread: N (NPT Thread), Port Size: 03 (3/8), Wiring Specification: 3m Lead Wire w/Connector, Output Specification: 1 (Pulse Output + Analog Output (1~5V))
Set Flow: 10 (1~10l/min), Thread: N (NPT), Port Size: 03 (3/8), Terminal Box: 1 [Terminal Box (Contact 1ab)], Neon Lamp: 0 (w/o Neon Lamp)
Set Flow: 10 (1~10l/min), Thread: Rc(PT), Port Size: 03 (3/8), Terminal Box: 1 [Terminal Box (Contact 1ab)], Neon Lamp: 3 [Neon Lamp (for 220VAC Red)]
Set Flow: 10 (1~10l/min), Thread: Rc(PT), Port Size: 03 (3/8), Terminal Box: 1 [Terminal Box (Contact 1ab)], Neon Lamp: 4 [Neon Lamp (for 220VAC Green)]
Set Flow: 20 (10~20l/min), Thread: Rc(PT), Port Size: 03 (3/8), Terminal Box: 1 [Terminal Box (Contact 1ab)], Neon Lamp: 1 [Neon Lamp (for 110VAC Red)]
Solenoid: No.1 Solenoid, Body Option: 4 (15A), Style: 0 (Energized Open/N.C.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 03 [3/8 (10,15A)], Thread: Rc, Voltage: 1 (100VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: L (Light)
Solenoid: No.1 Solenoid, Body Option: 4 (15A), Style: 0 (Energized Open/N.C.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 03 [3/8 (10,15A)], Thread: Rc, Voltage: 1 (100VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor)
Solenoid: No.1 Solenoid, Body Option: 4 (15A), Style: 0 (Energized Open/N.C.), Option: A (Brass, Copper or BC6 Body & Shading Coil, FPM Seal, Class B Coil), Port Size: 03 [3/8 (10,15A)], Thread: Rc, Voltage: 1 (100VAC 50/60HZ), Lead Wire: C (Conduit)
Function: 1 (2 Position Single), Body Option: 1 (Base Mounted Non Plug-in), Direct Manual Override: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 03 (Sub-plate Plug-in Terminal 3/8, Non-plug-in
Function: 1 (2 Position Single), Body Option: 1 (Base Mounted Non Plug-in), Direct Manual Override: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: B (Bottom Ported), Port Size: 03 (Sub-plate Plug-in Terminal 3/8, Non-plug-in Standard 3/8), Thread: N (NPT)
Function: 1 (2 Position Single), Body Option: 1 (Base Mounted Non Plug-in), Direct Manual Override: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: B (Bottom Ported), Port Size: 03 (Sub-plate Plug-in Terminal 3/8, Non-plug-in Standard 3/8), Thread: T (NPTF)
Function: 1 (2 Position Single), Body Option: 1 (Base Mounted Non Plug-in), Direct Manual Override: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: B (Locking Slotted Style), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 03 (Sub-plate Plug-in Terminal 3/8, Non-plug-in
Function: 1 (2 Position Single), Body Option: 1 (Base Mounted Non Plug-in), Direct Manual Override: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: E (Grommet Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 03 (Sub-plate Plug-in Terminal 3/8, Non-plug-in Standard 3/8)
Function: 1 (2 Position Single), Body Option: 1 (Base Mounted Non Plug-in), Direct Manual Override: 0 (Standard), Pilot: Internal Pilot, Voltage: 4 (220VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 03 (Sub-plate Plug-in Terminal 3