Basic Mounting CG1N20SCG120, #1 CG1N25SCG125, #1 CG1N32SCG132, #1 CG1N40SCG140, #1 CG1N50SCG150, #1 CG1N63SCG163, #1 CG1N80SCG180, #1 CG1N100SCG1100, #1 Foot : Add #2 Front flange : Add #3 Rear flange : Add #4 Front trunnion : Add #5 Rear trunnion : Add #6 1.6-9 Series CG1 With Mounting Bracket Clevis (mm) Bore (mm) Stroke range (mm) TH TF TE V RR L CZ CX B CD 20 25 32 40 50 63 80 100 25
P-1 = A (A B) / 4 H-1 = (A B) / 2 A = Maximum pressure value B = Minimum pressure value For low differential pressure For low pressure For compound pressure PSE533 PSE543 PSE563 For positive pressure For vacuum Pressure range C Display calibration function This function eliminates slight differences in the output values and allows uniformity in the numbers displayed.
Calculate the moment of inertia for A and B separately as shown in the figures on the right. A part B part Procedure Calculation Calculation example 1. Check the operating conditions, dimensions of attachment, etc. Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.
SMC has improved product performance and reliability with the redesigned SY series valve. The SY3000 and SY5000 have the same valve width as their predecessors, but the flow has been increased by up to 80%, allowing the valve size to be reduced. A built-in strainer in the pilot valve prevents trouble caused by foreign matter. By using H-NBR seal material for the main valve and seals, Ozone
SMC has improved product performance and reliability with the redesigned SY series valve. The SY3000 and SY5000 have the same valve width as their predecessors, but the flow has been increased by up to 80%, allowing the valve size to be reduced. A built-in strainer in the pilot valve prevents trouble caused by foreign matter. By using H-NBR seal material for the main valve and seals, Ozone
3 port single solenoid. , Body ported and base mounted types, Port size: M5, 1/8, Rc, G, NPT or NPTF threads, Available with CE approval?, VK300 BASE MT 1/8, VALVE, VK300 SOL VALVE 3-PORT, NA, VK300 BASE MT 1/8, 0.4867 lb
Please contact us for the latest version.sales@ocaire.com, VALVE, COMPACT, SGL, BRASS, VALVE, VDW VALVE 3-WAY BRASS, CC, VDW BODY PORT 1/8 NPT, .26598 lb
Please contact us for the latest version.sales@ocaire.com, VX3 BODY PT 1/8, VALVE, VX3 3-WAY MEDIA VALVE, DA, VX3 BODY PT 1/8
Please contact us for the latest version.sales@ocaire.com, VX3 BODY PT 1/8, VALVE, VX3 3-WAY MEDIA VALVE, DA, VX3 BODY PT 1/8
Please contact us for the latest version.sales@ocaire.com, VX3 BODY PT 1/8, VALVE, VX3 3-WAY MEDIA VALVE, DA, VX3 BODY PT 1/8, 0.85122 lb
4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery -Electrical equipment of machines (Part 1: General requirements) ISO 10218-1992: Manipulating industrial robots -Safety JIS B 8370: JIS B 8361: JIS B 9960-1: 1 ) JIS B 8433-1993: *2) 1. 2. 3. 1. 2. 3. 4
After tightening the fitting by hand, use a wrench to tighten the fitting an additional approximately 1/4 turn for a port size of M3 x 0.5 or 1/6 turn for a port size of M5 x 0.8. For elbow type fittings, tighten an additional 1/2 turn for a port size of M3 x 0.5 or 1/3 turn for a port size of M5 x 0.8 if gaskets are mounted in two places.
thread (mm) A B C D E F G H J K M P Q R S L Bore size (mm) 20 9.5 depth 5.4 51 43 8 12 10 M8 x 1.25 10 6 30 5.5 43 1/8 16.5 6 11.5 25 9.5 depth 5.4 53 45 8 14 12 M10 x 1.5 12 6 36 5.5 49 1/8 17 8 12 32 11 depth 6.5 66 56 10 18 14 M12 x 1.75 15 7 47 6.6 63 1/4 19.5 10 19.5 40 14 depth 8.6 75 65 10 22.4 19 M16 x 2 20 7 52 9 71 1/4 21.5 10 21.5 50 17.5 depth 10.8 81 70 11 28 24 M20 x 2.5 24
fluid power -General rules relating to systems IEC 60204-1: Safety of machinery -Electrical equipment of machines (Part 1: General requirements) ISO 10218-1992: Manipulating industrial robots-Safety JIS B 8370: JIS B 8361: JIS B 9960-1: -1) JIS B 8433-1993: *2) 1. 2. 3. 1. 2. 3. 4. 3 A / 1 1.5 *3) *3)1 1 () 4 IP8000ExdBT5 1. 1 IP8000 IP8100 420mADC()*1 23515(420mADC) 0.140.7MPa
How to Order 02 B ASS 00 3 Accessory Without bracket With bracket Body size 1 8 1 3 5 6 8 3 B 3 4 1 AS Port size Applicable series Port size 01 02 03 04 06 10 ASN 1 8 Style ASS100, 110 ASS300, 310 ASS300, 310 ASS500 ASS500, 600 ASS600 1 4 00 10 Meter-out control Meter-in control AQ 8 3 1 2 PAT.PEND Meter-in style is available only for ASS110 and ASS310. 3 4 1 ASV AK Thread N F Rc(PT) NPT
industrial robots-Safety JIS B 8370: JIS B 8361: JIS B 9960-1: -1 ) JIS B 8433: *2) 1. 2. 3. 1. 2. 3. 4
Bore size Bore size MLGClB RSMLGC , #1 (#1+#4) Bore size Bore size MLGClB SMLGC , #3 (#3+#4) 3.2-7 Series MLGC Front Flange Mounting/With Rear Plate MLGClFl-l-RStandard Stroke AN BP AG AM GK AB AL B GD A Bore size (mm) Stroke range (mm) AA AH AI AJ AK AO AP BZ GC 1/8 1/8 1/8 1/8 20 25 32 40 75, 100, 125, 150, 200 75 3.5 13 9 54 94 11 92 9 M8 32 28 134 150 108 140 135 Rc(PT) 73.5 88 4 16 9
-1992: Manipulating industrial robots-Safety JIS B 8370: JIS B 8361: JIS B 9960-1: -1 ) JIS B 8433-1993: 2) : : : 1. 2. 3. 1. 2. 3. 4