In case of option B [For Earth leakage breaker], HRS090--40/46L1 L2 L3 PE Cable tie holder Note: Hold the power supply cable by cable band. (Cable band is prepared by the user.) Fig. 3-11 Wiring of power supply cable HRS090 Series 3.3Installation 3-17 HRX-OMT002 Chapter 3 Transport and Setting Up Mount the power supply terminal cover using 4 screws.
(inch) Connection thread UNF NPT
M1 Weight (g) 4 6 6 8 6 8 10 8 10 8 10 10 12 Applicable tubing O.D. d T H D1 D2 L1 L2 L3 Model AS121-M5-F04 AS121-M5-F06 AS221-01-F06S AS221-01-F08S AS221-02-F06S AS221-02-F08S AS221-02-F10S AS321-02-F08S AS321-02-F10S AS321-03-F08S AS321-03-F10S AS421-04-F10S AS421-04-F12S 16 17 17 18.5 17 18.5 21 18.5 21 18.5 21 21 22 13 13 34 31 54 50 52 86 81 93 88 154 146 21 21.5 25.5 26 M5 x 0.8 28.3
L1 L2 L3 L4 L5 L6 L7 (1) L8 D Model Bore size ASV AS2000-01 AS2000-02 AS3000-02, 03 1 8 Rc Rc Rc , 40 5 17 54.5 16 15.5 50 30 10 4.5 AK 1 4 1 4 2 x M4 x 0.7 11.5 17 56 51.5 40 5 23 20 30 4.5 Effective thread depth 6 Reference dimensions 8 3 45.5 5.25 20.6 61 13.2 68 56 25 26 5.5 VCHC Note 1) L7: Reference dimensions Dimensions: AS5000 ASR ASQ 2 x 1/4 to 1/2 2-1/4 to 1/2 74.9 (Max. 82.9)
Stroke Center trunnlon/ (T) Z+ l l2 Stroke (mm) , TT Without auto switch capability With auto switch capability Made to order rio,.!.. G Ports C,1& NPT Ports liB .$$8 pg. 22 tor Mountin 1 pc. BasidWithout bfacll.et Bore size 3 pes, 1. k: n ! npes. FOOl alldilional options F Flan e T, Center trunnion Applicable auto swnch J32 32mm 40 40mm 50mm 63mm BOmm "so , 63' * Re!el lO tabIt be!
o Cylinder Theoretical Force Weight (gO The weight in parenthesisis IS with auto SWitch , , r Operating pressure(kgffcm') Bore size(mm)' Bore size T,y~e,ol mounti,ng Action (mm) 10 y 6 . 3 '>15 3 5 7 ;;V jE i , 44(51) 60(67) 99 (106) 5 IN 0.63 1.06-L2~ . -/---[-~ 6 50(61) 66(77) 10811 19) 10 OUT 0.85 ~.98 Series CJP 118(129) 15 Stroke 56(67~+ 73(84) [-'t-Id~K95 . 4.12 Nosemount lO ~ (mm
T ype ;A .S C I ' D E F Y J ~ _L ~ " 4 15 9.5 14 4 4.5 6.5 7,5 ~ ZPlODQ Dl0 10 12 4 13 10,7 15 6 ::l 4 15 9.5 " ) L :l2 ~ 4 _'5 10 1~ ZP16DQ 016 16 18. '4 13, 11;.]11 1~ ,7 ZP4 ::l U40 4, 43 7 18 13.7 18.5 ZP25DO 025 25 28 4 15 15,5 20 10 I 0$0, I 50 53 7 18 14.7 ' 19.5 ZP40DO 0'\0 ,40 43 7 18 ~ "24.2 29 I .t~ lIE lndlcate malerlallo be selected at the end of part No.
32.5 4.5 4.5 6.6 6.6 2.8 2.8 4 4 17 19 24 26 2 2 3.2 3.2 34 38 48 52 29.5 33.5 42 46 44 48 62 66 8 8 9.2 10.7 4.5 5 5.8 5.8 Data Foot bracket material: Carbon steel Flange style: CQSWF/CDQSWF B + Stroke L1 + Stroke A + 2 (Stroke) Rod end male thread Rod end nut L3 + Stroke A1 + 2 (Stroke) Flange Style With auto switch Without auto switch Bore size (mm) Stroke range (mm) FZ FX FV FT FD L3 L2
Display Pressure: 1.0MPa, Connection Thread: R 1/4, Indicator Light: L2 [Neon Light (100 VAC/220 VAC)], Attachment: -, Option: -
Display Pressure: 1.0MPa, Connection Thread: R 1/4, M5 Female, Indicator Light: L2 [Neon Light (100 VAC/220 VAC)], Attachment: Clear Cover Non Removable, Wrench Tighten, Option: -
Display Pressure: 1.0MPa, Connection Thread: R 1/4, Indicator Light: L2 [Neon Light (100 VAC/220 VAC)], Attachment: Clear Cover Non Removable, Wrench Tighten, Option: -
Display Pressure: 1.0MPa, Connection Thread: R 1/4, M5 Female, Indicator Light: L2 [Neon Light (100 VAC/220 VAC)], Attachment: Clear Cover Non Removable, Wrench Tighten, Option: Lead Wire Length 3 m
Display Pressure: 1.0MPa, Connection Thread: R 1/8, M5 Female, Indicator Light: L2 [Neon Light (100 VAC/220 VAC)], Attachment: -, Option: -
Display Pressure: 1.0MPa, Connection Thread: R 1/8, M5 Female, Indicator Light: L2 [Neon Light (100 VAC/220 VAC)], Attachment: None, Option: Lead Wire Length 3 m
Display Pressure: 1.0MPa, Connection Thread: R 1/8, M5 Female, Indicator Light: L2 [Neon Light (100 VAC/220 VAC)], Attachment: Clear Cover Removable, Wrench Tighten, Option: Lead Wire Length 3 m
Back Pressure Check Valve: K (Built-in), Coil Specification: Standard, Type: Plug-in, Rated Voltage: 5 (24V DC; Use 24 V DC for EX180, EX510, and PC Wiring), Common Specifications: Positive Common, Connector Entry: C (Dedicated for Centralized Wiring), Light, Surge Suppressor: U (Light/Surge Suppressor, Non-polar Type), Switch: None, Manual Override: Non-locking Push Type, A,B Port Size: L2
Pilot, Back Pressure Check Valve: None, Coil Specification: Standard, Type: Plug-in, Rated Voltage: 5 (24V DC; Use 24 V DC for EX180, EX510, and PC Wiring), Common Specifications: Positive Common, Connector Entry: C (Dedicated for Centralized Wiring), Light, Surge Suppressor: U (Light/Surge Suppressor, Non-polar Type), Switch: None, Manual Override: Non-locking Push Type, A,B Port Size: L2
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: L2 [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: None]
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: L2 [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: None]
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: L2 [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: None]