(AR20(K)/25(K)/30(K)/40(K)) AR10 AR20(K) AR25(K) AR30(K) AR40(K) AR20(K)/25(K)/30(K)/40(K) Hook spanner Nominal Tightening torque 2.0 0.2 Nm 2.5 0.2 Nm 3.5 0.3 Nm 4.0 0.4 Nm AR20(K) AR25(K) AR30(K) AR40(K) AR20(K) AR25(K) AR30(K) AR40(K) 34/38 40/42 52/55 52/55 Assembly (Bracket assembly) 1) Mount the bracket to the product.
Model Option AR20(K)-B AR25(K)-B AR30(K)-B AR40(K)-B AR40(K)-06-B AR50(K)-B AR60(K)-B Bracket assembly Note 1) AR23P-270AS AR28P-270AS AR33P-270AS AR43P-270AS AR52P-270AS Set nut AR23P-260S AR28P-260S AR33P-260S AR43P-260S Note 2) Round type Note 3) Standard G36-10-01 G46-10-01 0.02 to 0.2 MPa setting G36-4-01 G46-4-01 (with color zone) Standard G36-10-01-L G46-10-01-L Pressure Round type
A 10 B 15 C 20 Produced upon receipt of order (Robotic cable only) Refer to the specications Note 2) on pages 9 and 10.
A B !
(2) (10.2) 50 [ms] 40 30 T8 T9 20 T7 10 T6 T5 0 0 1000 2000 3000 4000 5000 6000 [r/min] LE-T10.3.2 [] LE-T5LE-T6LE-T730 LE-T8LE-T910 6 10. 10.4 a 1 10 8 5 10 7 1 10 7 5 10 6 a: [ms] 1 10 6 5 10 5 b: SSCNET 1 10 5 5 10 4 1 10 4 b 5 10 3 1 10 3 4 7 10 20 40 70 100 200 [mm] 10.5 2500kVA1mAC240V()LECSS2T5LECSS2-T9AC200V (A0-P) (L1L2L3) (L11L21) LECSS2-T5LECSS2-T7 LECSS2-T8
Enable Generates an error. 1 Unit Disable Does not generate an error. -10..10 V -5..5 V -20..20 mA 0..10 V 2 Analogue input range Sets the analogue input device range. Selects the analogue input range. -10..10 V Channel 0..5 V 1..5 V 0..20 mA 4..20 mA Offset binary Offset binary.
P, E port location U D B U side (2 to 10 stations) D side (2 to 10 stations) Both sides (2 to 20 stations) Pilot type Internal pilot External pilot Nil R A, B port size (inch) A, B port size (metric) P, E port Applicable series P, E port Applicable series A, B port A, B port Symbol C4 C6 C8 C8 C10 C12 M Symbol N3 N7 N9 N9 N11 M One-touch fitting for 4 One-touch fitting for 6 One-touch fitting
Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 3 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 4 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 5 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Low tank fluid level 1 CH1 abnormal high circulating fluid temp. 2 Reservation
output signal 3 B contact (normally closed) By default 2.4.2 Contact output signal 4 to 6 Contact output signal 4 to 6 can be set to "signal type", "contact form".
Parameter Definition Item Content Default setting 0: -10..10 V 1: -5..5 V 2: -20..20 mA 3: 0..10 V 5 Analog Range Set the analog input range per channel. Selects the analog input range. 0..10 V 4: 0..5 V 5: 1..5 V 6: 0..20 mA 7: 4..20 mA 0: None None 6 Analog Filter Sets analog input filtering time per channel.
Model Option 10-/21-AR20(K)-B 10-/21-AR25(K)-B 10-/21-AR30(K)-B 10-/21-AR40(K)-B 10-/21-AR40(K)-06-B 10-/21-AR50(K)-B 10-/21-AR60(K)-B Bracket assembly Note 1) AR50P-270AS Note 2) AR20P-270AS Note 3) Note 3) AR25P-270AS AR30P-270AS AR40P-270AS Set nut AR20P-260S AR25P-260S AR30P-260S AR40P-260S 10: G49-10-01, 21: G49-10-01-MS-X3 Standard Pressure gauge Note 4) 10: G49-4-01, 21: G49-4-01
6 8, 5/16 10, 3/8 1/4 Fitting size 6 8, 5/16 10, 3/8 1/4 Port Plug VVQ0 58A 10 Single unit regulator/ Port plug for regulator block 10 Semi-standard Description None Oil-free Symbol Nil X17 239
6 8, 5/16 10, 3/8 1/4 Fitting size 6 8, 5/16 10, 3/8 1/4 Port Plug VVQ0 58A 10 Single unit regulator/ Port plug for regulator block 10 Semi-standard Description None Oil-free Symbol Nil X17 239
VY1 How to Order G PPA Internal pilot operated relieving type regulator AR 25 4 BG R 02 Option Nil Flow direction: Right Left AL None Regulator R Body size Accessory 4 6 8 9 1 2 1 Symbol Description Applicable model Port size 1 Nil 1 4 02 03 04 06 10 12 14 20 2 1 With bracket AR45 to 65 AR25 AR35 B 8 3 2 G46-10-02 G46-2-02 Gauge 1 2 3 4 G Regulating pressure range Pressure gauges are shipped
B 2 B 2 2B 1 1 (95.2) 3/5 E 4 A 4 A P 1 P 1 4A 68.8 B 2 B 2 B 2 B 2 3/5 E 3/5 E 4 A 4 A 4 A 4 A
Option J: With drain guide Bracket (Option) 1/4B female thread T: With element service indicator Maintenance space HA Drain AT ID AMG AFF Element service indicator Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 10 10 10 10 10 10 10 10 10 I 56 66 66 80 80 90 90 100 150 J 15 20 17 22 19 25 21 30 40 K 5 8 8 8 8 10 10 10 15 L 9 12 12 14 14 14 14 16 20 M 5.5
AL Model Port size A B C D M N P R B B E F G H J K L M5 X 0.8 38.5 50 70.5 70.5 88 88 108 108 108 16 23 26 26 33 36 40 40 40 105 147.5 4.5 5.5 7 7 9 9 12 12 12 50 80 80 80 105 105 105 105 105 91 140 181 181 238 253 300 310 315 5 5 7 7 7 7 10 10 10 7.5 8.5 11 11 13 13 16 16 16 25.5 38 38 38 41 40.5 48 48 48 84.5 124.5 153 153 188 189.5 268 282 282 26 56.8 60.8 60.8 65.5 69.5 75.5 75.5 78 25
G46-10-01 2 pcs. G46-10-01 2 pcs. G27-10-R1-X209 2 pcs. G27-10-R1-X209 2 pcs.
30 40 0 40 80 120 160 100 0 200 300 Outlet air flow rate (l/min (ANR)) Outlet air flow rate (l/min (ANR)) IDG30H (Type B products group) IDG50H (Type B products group) P1 = 0.3 MPa 0 P1 = 0.3 MPa 0 Outlet air atmospheric pressure dew point (C) Outlet air atmospheric pressure dew point (C) P1 = 0.5 MPa P1 = 0.5 MPa 10 10 P1 = 0.7 MPa P1 = 0.7 MPa 20 20 HA 30 30 AT 40 40 ID 50 50 600 0 200