-LL-01 (-F2) Insulation: Red (+) Insulation: Black () 4.1 0.3 mm2 12 14.7 L 104 (Lead wire length) Cable type (TT) 52-SY5120-TT-01 (-F2) Lead wire marking No.1 (+), No.2 () 5.9 0.75 mm2 L 120.8 (Lead wire length) Max.10 5 ATEX Compliant Body Ported Type Series 52-SY5000 Dimensions 2-position double L plug connector (L) 52-SY5220-L-01 (-F2) 22.6 16.7 2 x M3 x 0.5 Threads depth 3.5 (For bracket
Load weight (kg) Caution The cylinder should be mounted in m1 orientation if maximum dustproofing is required. m m m Moment (Nm) M = F x L F3 M = F x L M = F x L F F2 L2 L1 L3 Maximum load weight Select the load weight from within the range of limits shown in the graphs. Note that the maximum allowable moment value may sometimes exceed even the operating limits shown in the graphs.
8.1 C4 4(5/32) 10.1 8.1 C6 6 10.3 8.3 C6 6 10.3 8.3 C8 8(5/16) 12 10 C8 8(5/16) 12 10 N7 1/4 10.3 8.3 N7 1/4 10.3 8.3 PFM7-01/02--X693 PFM7S-01/02--X693 A B C() A B C() Rc1/81/4 Rc1/81/4 NPT1/81/4 NPT1/81/4 13 11 17 13 11 17 G1/8 G1/8 G1/4 17 15 21 G1/4 17 15 21 -73No.PF-OMJ0005CN-I PFM7-C4/C6/C8/N7--X694 PFM7S-C4/C6/C8/N7--X694 A B A B C4 4(5/32) 10.1 36.1 C4 4(5/32) 10.1 8.1 C6 6 10.3
Applicable strokes:150, 250, 350, 450, 550, 650, 750, 850, 950 Example) LJ1H2021SC-150-F2-X2 Allowable Moment (Nm) Allowable static moment Allowable dynamic moment Pitching Rolling Yawing Mounting orientation Load movement direction Model 71 83 75 LJ1H20 Horizontal/Lateral Horizontal/Lateral Lateral Horizontal a Mep a = 1000 2000 L1 (mm) L2 (mm) L3 (mm) Pitching Rolling Yawing m : Transfer
Applicable strokes:150, 250, 350, 450, 550, 650, 750, 850, 950 Example) LJ1H2021SC-150-F2-X2 Allowable Moment (Nm) Allowable static moment Allowable dynamic moment Pitching Rolling Yawing Mounting orientation Load movement direction Model 71 83 75 LJ1H20 Horizontal/Lateral Horizontal/Lateral Lateral Horizontal a Mep a = 1000 2000 L1 (mm) L2 (mm) L3 (mm) Pitching Rolling Yawing m : Transfer
Applicable strokes:150, 250, 350, 450, 550, 650, 750, 850, 950 Example) LJ1H2021SC-150-F2-X2 Allowable Moment (Nm) Allowable static moment Allowable dynamic moment Pitching Rolling Yawing Mounting orientation Load movement direction Model 71 83 75 LJ1H20 Horizontal/Lateral Horizontal/Lateral Lateral Horizontal a Mep a = 1000 2000 L1 (mm) L2 (mm) L3 (mm) Pitching Rolling Yawing m : Transfer
Applicable strokes:150, 250, 350, 450, 550, 650, 750, 850, 950 Example) LJ1H2021SC-150-F2-X2 Allowable Moment (Nm) Allowable static moment Allowable dynamic moment Pitching Rolling Yawing Mounting orientation Load movement direction Model 71 83 75 LJ1H20 Horizontal/Lateral Horizontal/Lateral Lateral Horizontal a Mep a = 1000 2000 L1 (mm) L2 (mm) L3 (mm) Pitching Rolling Yawing m : Transfer
(mm) L3 1000 a = 3000 a = 2000 m Mey a 0 2 4 6 8 10 Transfer load m (kg) Refer to page 145 for deflection data. 44
Up to 1000 1/4 181 10 11 53 77 236.5 247 26.5 The dimension NA(42.5) is wider than dimension TX(40).
F2: The force that is created by the port A pressure (PA) that passes through the feedback passage and acts on the spool surface, and the spring force. OFF state { F1< F2 condition: See figure 1. AR1 (Exhaust air) PB (Supply air) ON state PA (Supply air) BR2 (Exhaust air) { Immediately after turning on F1> F2: See figure 3. Thereafter F1 = F2: See figure 2.
/L1/L3) PLC OFF 2)(L11L21) ON [AL.
, C8 (A, B port) Individual SUP spacer Control unit Pressure switch Air release valve Stations Filter regulator Pressure switch Air release valve Pressure switch Electrical entry D side Rc 1/4 Po port 2-Rc 1/8 Pilot EXH port n: Stations Stations L L1 L2 L3 (MP) L3 (AP) Formula L1 = 28 x n + 47 L2 = 28 x n + 56 L3 = 28 x n + 194 L3 = 28 x n + 235.5 3 131 140 278 319.5 4 159 168 306 347.5 5
, C8 C6: One-touch fitting assembly for 6 B B B 4 2-Rc 1/8, 1/4, C6, C8 C6: One-touch fitting assembly for 6 C8: One-touch fitting assembly for 8 VQD 2 A C8: One-touch fitting assembly for 8 B 23 P = 22 L1 L2 L3 (For C6, C8) ( 9.5) DIN rail clamp screw 80 ( 9.5) 2-M4 mounting hole (For C6, C8) (For C6, C8) 4.5 2-M6 mounting hole IN IN IN IN 5.5 80 6.5 (40) 69.5 58 37.5 39.5 Residual pressure
6.5 mm, and 9 mm for C6.
Local Area: (800) 258-9200-www.stevenengineering.com VV5Z5-20-01 VV5Z5-20-C6 VV5Z5-20-C8 VV5Z5-21-01 VV5Z5-21-C6 VV5Z5-21-C8 1/8 C6 C8 1/8 C6 C8 0.55 0.49 0.51 0.54 0.50 0.50 0.26 0.25 0.25 0.26 0.24 0.20 2.3 2.0 2.1 2.3 2.1 2.1 0.57 0.37 0.45 0.55 0.36 0.50 0.35 0.32 0.38 0.36 0.32 0.37 2.2 1.4 1.7 2.1 1.4 1.8 1/8 1/8 1/8 1/4 1/4 1/4 VZ52 Note) Value at manifold base mounted, 2 position
specification) L2 5 (Rail mounting hole pitch: 12.5) L1 (Station n1) (Station 1) (Station 1) n1 = Valve stations n2 = Input block stations (Station n2) Light/Surge voltage suppressor L2 = L1 10.5 L3 = 10.5 x n1 + 53 L4 = L3 + 81 + 21 x n2 L5 = (L1 L4)/2 L6 = 10.5 x n1 + 42 L7 = 21 x n2 + 81 60 45.5 10 11.8 (for DIN rail mounting) (7.5) L1: DIN rail overall length (mm) Valve stations (n1
Station n L1 L2 L3 L1 L2 L3 Station 2 62 53 47 63 54 48 3 78 69 63 80 71 65 Station 20 350 341 335 369 360 354 4 94 85 79 97 88 82 5 110 101 95 114 105 99 6 126 117 111 131 122 116 7 142 133 127 148 139 133 8 158 149 143 165 156 150 9 174 165 159 182 173 167 10 190 181 175 199 190 184 11 206 197 191 216 207 201 12 222 213 207 233 224 218 13 238 229 223 250 241 235 14 254 245 239 267 258 252
(Station n2) (Station 1) Light/surge voltage suppressor (Station n1) (Station 1) With option 60 45.5 37.5 10 74.5 (For DIN rail mounting) (7.5) 11.8 n1 = Valve stations n2 = Input block stations Individual EXH spacer Individual SUP spacer L2 = L1 10.5 L3 = 10.5 x n1 + 53 L4 = L3 + 81 + 21 x n2 L5 = (L1 L4)/2 L6 = 10.5 x n1 + 42 L7 = 21 x n2 + 81 L1: DIN rail overall length Valve stations
Station 1) (Station n) (Station 1) (Station n) (Light/Surge voltage suppressor) (Light/Surge voltage suppressor) + + + + + + + + 54.1 [61.1] 54.1 [61.1] 38.7 38.7 25.5 25.5 A A A A (Pitch) P=16 19.5 (Pitch) P=17 M5 x 0.8 (A port) 8.5 1/8 (A port) 8.5 19.5 Station n L1 L2 L3 L1 L2 L3 Station 2 62 53 47 63 54 48 Station 20 350 341 335 369 360 354 3 78 69 63 80 71 65 4 94 85 79 97 88 82 5 110