SMC Corporation of America
Elite Part Number Search
Search Results "53-SY5120-TT6-01F-F2"

Actuation: 2-Position Single, Electrical Entry: Terminal Type, Lead Wire Length: 600mm, Maximum Length for L-type, Manual Override: Non-locking Push Type, A,B Port: 1/8, Thread Type: NPT, Bracket: w/Side Bracket

T.T. 16.5 1.5 1.5 Max. 6 53 22.1 3 Symbol (91.6) (75.1) (OUT) 2 NC 10 12 4.5 36 13.5 18 13.5 18 VM4 SMC NO 3 (N.C.) 1 (N.O.) 22.5 OUT 21 25 6.5 mm T.T. 1.6 mm O.T. 4.9 mm P.T. 26 N F.O.F. 35 3 x 1/8 4 x 4.5 mounting hole Twist selector (2 position) VM430-01-34R/B/G/Y ON Panel mounting hole T.T. 40 OFF Max. 6 39 38 24.5 Symbol 1.5 1.5 28 (OUT) 2 10 12 53 22.1 3 3 (N.C.) 1 (N.O.) (103.1) (75.1

H 28 30 36 44 54 G 33 42 44 50 61 F 45 55 58 65 76 E 22 21 26 D 34 46 63 67 78 C 40 53 70 75 90 B 20 29 39 42 53 A 59 78 107 110 134 I 45 55 63 69 81 Model Piping port VHS20 VHS30 VHS40 VHS40-06 VHS50 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 5-8-22 5 Series VHS Specific Product Precautions Be sure to read before handling. Air Supply Precautions on Design Warning Warning 1.

VM830-01-00 Actuator Basic Roller lever Adjustable roller lever Adjustable rod lever VM830-01-01 VM-01F VM830-01-13 VM830-01-14 VM-13F VM-14F Actuator replacement is available.

1 Mechanical Valves Series VM Mechanical Valves Series VM Mechanical Valves SA VA Model VM1000 VM100 VM200 VM400 VZM500 VZM400 VFM300 VFM200 VM800 SA Dimensions (mm) Side ported 11 x 36 x 16 Bottom ported 11 x 28 x 25 Side ported 17 x 44 x 25 Bottom ported 17 x 44 x 30 25 x 40 x 52 21 x 35 x 53 18 x 28 x 87 18 x 30 x 91 26 x 35 x 94 23 x 40 x 115 30 x 40 x 57 VA VM Courtesy of Steven Engineering

Load (kg) m1 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com m4 m2 m3 Moment (Nm) F3 M3=F3 x L3 L3 F1 M1=F1 x L1 F2 M2=F2 x L2 L1 L2 1.

F2: The force that is created by the port A pressure (PA) that passes through the feedback passage and acts on the spool surface, and the spring force. OFF state { F1< F2 condition: See figure 1. AR1 (Exhaust air) PB (Supply air) ON state PA (Supply air) BR2 (Exhaust air) { Immediately after turning on F1> F2: See figure 3. Thereafter F1 = F2: See figure 2.

Applicable strokes: 550, 650, 750, 850, 950 Example) LJ1H2021PC-550-F2-X2 Body weight Operating temperature range Work load Rated thrust Maximum speed Note) Performance 1000 1000 930 740 600 500 0.02 AC servomotor (100W) Incremental system Ground ball screw 15mm, 20mm lead High rigidity direct acting guide With coupling LC1-1B2H(Refer to page 185 for details.)

Refer to page 100 for part numbers. 53 Non-standard Motor Series LJ1H20 High Rigidity Direct Acting Guide Rolled Ball Screw Motor Output 100W 15mm/10mm lead Horizontal Mount How to Order G NA 1 F W X10 Stroke 2 LJ1H20 Cable entry direction Top entry Cable entry direction Power supply voltage Motor specification Matsushita Electric Industrial Co., Ltd.

Applicable strokes: 150, 250, 350, 450 Example) LJ1H1011PB-150-F2-X2 Body weight Operating temperature range Work load Rated thrust Maximum speed Positioning repeatability Motor Encoder Lead screw Guide Motor/Screw connection Model Performance 0.02 AC servomotor (50W) Incremental system Ground ball screw 12mm, 12mm lead High rigidity direct acting guide With coupling LC1-1B1H(Refer to page

With light/surge voltage suppressor Note) D: Push-turn locking slotted type Note) The electrical connection will be +COM. spec. 75 Series SJ3A6 Dimensions SS3J3-V60U/D/B Stations One-touch fitting [3/5(E) vacuum pressure port] Applicable tubing O.D: 8 (Pitch) P = 10 M5 x 0.8 [2(B) vacuum pad port] 23.6 12.8 15.6 23.8 3/5 (With needle fully opened 62.8) F2 F2 F2 F2 F2 30.6 46.2 1 2 2 2 2 2

MY2C MY2H Load mass (kg) m1 MY3A MY3B Caution MY3M The cylinder should be mounted in m1 orientation if maximum dustproofing is required. m2 m3 Moment (Nm) M3=F3 x L3 F3 F2 M1=F1 x L1 F1 M2=F2 x L2 L2 L1 L3 Maximum Load Mass Select the load from within the range of limits shown in the graphs.

Suction flow rate When obtaining the suction flow rate at a vacuum pressure of 53 kPa from the ZH07DS flow rate characteristics graph, the suction flow rate is 5 L/min (ANR).

MY 500 500 500 Load weight (kg) m1 CY 300 300 300 MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com MY1HT63 CX Moment (Nm) Moment (Nm) Moment (Nm) MY1HT63 MY1HT63 m2 m3 Moment (Nm) D100 100 100 MY1HT50 MY1HT50 MY1HT50 M2 = F2 x L2 F3 M3 = F3 x L3 F2 M1 = F1 x L1

EXH Flow Rate Characteristics Model Port size Flow rate characteristics Model Standard specifications P1 P2 A B C D E F G H I VHS20 1/8, 1/4 1/8 66.4 22.3 40 37.5 14 46.6 33.6 28 43 VHS30 1/4, 3/8 1/4 80.3 29.4 53 49 19 52 38 30 49 VHS40 1/4, 3/8, 1/2 3/8 104.9 38.5 70 63 22 58 44 36 63 VHS40-06 3/4 1/2 110.4 42 75 63 22 58 44 44 63 VHS50 3/4, 1 1/2 134.3 53 90 76 26 76 61 53 81 IN, OUT EXH

Up to 1000 1/4 181 10 11 53 77 236.5 247 26.5 The dimension NA(42.5) is wider than dimension TX(40).

Refer to page 100 for part numbers. 53 54 Non-standard Motor Series LJ1H20 High Rigidity Direct Acting Guide Rolled Ball Screw Motor Output 100W 15mm/10mm lead Horizontal Mount How to Order Stroke 2 LJ1H20 G NA 1 F W X10 Cable entry direction Top entry Cable entry direction Power supply voltage Motor specification Matsushita Electric Industrial Co., Ltd.

Product Precautions p. 165 26 Variations Basic Pad ZP Series Vacuum inlet direction Flat type Flat type with ribs Bellows type Thin flat type Thin flat type with ribs Deep type Vacuum inlet direction Single unit p. 32 p. 51 p. 68 p. 87 p. 96 p. 105 VAC Vertical Vertical Lateral Lateral ZPT VAC p. 33 p. 34 p. 51 p. 52 p. 69 p. 70 p. 87 p. 96 p. 105 p. 106 With adapter ZPR p. 35 p. 37 p. 53