32 AS131F-U10/32 6, 10, 16, 20 10-32 UNF AS221F-N01 AS231F-N01 20, 25, 32 NPT 1/8 AS221F-N02 AS231F-N02 20, 25, 32, 40 NPT 1/4 AS321F-N02 AS331F-N02 40, 50, 63 NPT 1/4 Special tool Part number: AS-T-1 AS321F-N03 AS331F-N03 40, 50, 63 NPT 3/8 AS421F-N04 AS431F-N04 63, 80, 100 NPT 1/2 Note 1) Elbow type only Note 2) Meter-out and meter-in types can be visually differentiated by the flow direction
, 100 AS421FG-04 AS131FG-U10/32 10-32UNF 6, 10, 16, 20 AS121FG-U10/32 AS231FG-N01 NPT1/8 20, 25, 32 AS221FG-N01 Elbow type AS231FG-N02 NPT1/4 20, 25, 32, 40 AS221FG-N02 AS331FG-N02 NPT1/4 40, 50, 63 AS321FG-N02 AS331FG-N03 NPT3/8 40, 50, 63 AS321FG-N03 AS431FG-N04 NPT1/2 63, 80, 100 AS421FG-N04 Note 1) The meter-out and meter-in types can be visually determined by the flow direction symbol
Body Size: 40, Pipe Thread: N (NPT), Port Size: 04 (1/2), Mounting: B (w/Bracket), Nominal Filtration Rating: 80 (80µ), Water Removal Type: T (Large Flow Type), Semi-standard: 6RZ (6 + R + Z)
Body Size: 30, Pipe Thread: N (NPT), Port Size: 02 (1/4), Mounting: B (w/Bracket), Nominal Filtration Rating: 80 (80µ), Water Removal Type: T (Large Flow Type), Semi-standard: 6RZ (6 + R + Z)
100 R 1/2 Elbow type AS121F-U10/32 AS131F-U10/32 6, 10, 16, 20 10-32 UNF AS221F-N01 AS231F-N01 20, 25, 32 NPT 1/8 AS221F-N02 AS231F-N02 20, 25, 32, 40 NPT 1/4 AS AS321F-N02 AS331F-N02 40, 50, 63 NPT 1/4 AS321F-N03 AS331F-N03 40, 50, 63 NPT 3/8 ASP AS421F-N04 AS431F-N04 63, 80, 100 NPT 1/2 ASN Note 1) Elbow type only Note 2) Meter-out and meter-in types can be visually differentiated
AS131FG-U10/32 AS121FG-U10/32 6, 10, 16, 20 10-32 UNF AS231FG-N01 AS221FG-N01 20, 25, 32 NPT 1/8 AS231FG-N02 AS221FG-N02 20, 25, 32, 40 NPT 1/4 AS AS331FG-N02 AS321FG-N02 Inch sizes are now available for all models. 40, 50, 63 NPT 1/4 ASP AS331FG-N03 AS321FG-N03 40, 50, 63 NPT 3/8 AS431FG-N04 AS421FG-N04 63, 80, 100 NPT 1/2 ASN Note 1) Meter-out and meter-in types can be visually differentiated
) N02 NPT1/4 (M5 female threaded) F02 G1/4 (M5 female threaded) C01 Rc1/8 A2 URJ1/4 (Face seal fitting) B2 TSJ1/4 (Compression fitting) ZS-46-B Panel mount adapter + Front protection cover ZS-46-D D *2 Under the New Measurement Act, switches with the units selection function are not permitted for use in Japan. *3 Fixed unit: kPa, MPa t Piping direction y Option 1 Bottom ported (t Piping
C08 C10 C12 02 N02 F02 C04 C06 C08 02 N02 F02 C08 C10 C12 02 N02 F02 C04 C06 C08 02 N02 F02 IN port size IN port size Construction The construction and materials are the same as the standard product. Refer to Construction on page 323. The symbol stands for unavailable combination. The symbol stands for unavailable combination.
Dimensions L4 D3 H (Hexagon width across flats) T2 L3 A L2 D1 D2 T1 L1 Dimensions A AS120-U10/32-T 10-32 UNF 10-32 UNF AS120-M5-T M5 x 0.8 8 9 M5 x 0.8 Model T2 H D1 T1 D2 D3 L1 L2 L3 L4 Weight (g) 13 9 4.5 10 31 10.3 0.7 27.4 AS220-N01-ST NPT 1/8 12.7 NPT 1/8 AS220-F01-ST G 1/8 AS220-01-ST Rc 1/8 12 14.3 R 1/8 33 14.6 7 18 34.7 13.2 1.5 31.6 AS220-N02-ST NPT 1/4 17.5 NPT 1/4 AS220-F02-ST
133-51 0.91 (231 0.47 (121 0.81 i20.5) 0.39 (10) Millimeters in Parentheses Millimeters in Parontheses NVM220-N02-08 230-N02-08 NVM220-N02-07 230-N02-07 Panel Mounling Panel Mounting F O F ' 1 2 3 s l b s ( 5 6 k 9 ) P T 0 138 in (3 5mm) o,T 0 079 in (2mm) T T 0 216 in (5 5mm) F O F ' 2 6 5 l b s , ( 1 2 k g ) T T 60" '75 PSIG (5 Kgf/cm2) '75 PSIG (5 Kgf/cm2) A B c D E F G A B c D E F G
133-51 0.91 (231 0.47 (121 0.81 i20.5) 0.39 (10) Millimeters in Parentheses Millimeters in Parontheses NVM220-N02-08 230-N02-08 NVM220-N02-07 230-N02-07 Panel Mounling Panel Mounting F O F ' 1 2 3 s l b s ( 5 6 k 9 ) P T 0 138 in (3 5mm) o,T 0 079 in (2mm) T T 0 216 in (5 5mm) F O F ' 2 6 5 l b s , ( 1 2 k g ) T T 60" '75 PSIG (5 Kgf/cm2) '75 PSIG (5 Kgf/cm2) A B c D E F G A B c D E F G
Body Size: 20, Pipe Thread: NPT, Port Size: 1/4, Mounting: w/o Mounting Option, Nominal Filtration Rating: 80µ, Water Removal Type: Large Flow Type, Semi-standard: Name Plate And Caution Plate For Bowl In Imperial Unit (PSI, °F)
Body Size: 20, Pipe Thread: NPT, Port Size: 1/4, Mounting: w/o Mounting Option, Nominal Filtration Rating: 80µ, Water Removal Type: Large Flow Type, Semi-standard: 6 + Z
Body Size: 20, Pipe Thread: N (NPT), Port Size: 02 (1/4), Mounting: w/o Mounting Option, Nominal Filtration Rating: 80 (80µ), Water Removal Type: T (Large Flow Type), Semi-standard: Z (Name Plate And Caution Plate For Bowl In Imperial Unit (PSI, °F))
Body Size: 20, Pipe Thread: N (NPT), Port Size: 02 (1/4), Mounting: w/o Mounting Option, Nominal Filtration Rating: 80 (80µ), Water Removal Type: T (Large Flow Type), Semi-standard: 6Z (6 + Z)
0 i t !2 q !1 @0 !7 t !2 u !1 !7 !0 t !2 !7 !1 !5 !6 Component Parts Description Note Description No. Material Material Note No.
(t) is given by the graph. Then, the charge time (T) for a 100 L tank: With the pressure increase ratio from 2.0 to 3.0, the charge time of 147 58 = 89 sec. (t) is given by the graph. Then, the charge time (T) for a 10 L tank: T = t x = 3.2 x = 32 (s). V 10 T = t x = 89 x = 89 (s).
mA 1 V -S/-R () NPN 2 Max.28 V80 mA 1 V R15 V 1 k S420 mA 12 V 300 24 V 600 50 -S/-R () NPN 2 Max.28 V80 mA 1 V -17No.PS-OMM0002CN-F -V/-T () PNP 2 Max.80 mA 1 V T15 V 1 k V420 mA 12 V 300 24 V 600 50 -V/-T () PNP 2 Max.80 mA 1 V -A NPN2 Max.28 V80 mA 1 V -B PNP2 Max.80 mA 1 V -18No.PS-OMM0002CN-F ONOFF () ON OFF ON5OFF 20 P 1 H_1 [Pa] ON OFF [s] -19No.PS-OMM0002CN-F
T Metric Size L4 L5 A1 A2 M Max.