SMC Corporation of America
Elite Part Number Search
Search Results "AL20-01-6CR-A"

Installation at indoor site 1 In case of facility having a large installation area (that can vent the air naturally) Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2 In case of facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air

Selected for contact output 1 AL.01 Contact output 2 function RMT Contact output 2 operation A Selected for contact output 2.

For a facility having a small installation area (that can not vent the air naturally): Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level. 3.

Selected for contact output 1 AL.01 Contact output 2 function RMT Contact output 2 operation A Selected for contact output 2.

Selected for contact output 1 AL.01 Contact output 2 function RMT Contact output 2 operation A Selected for contact output 2.

Selected for contact output 1 AL.01 Contact output 2 function RMT Contact output 2 operation A Selected for contact output 2.

Selected for contact output 1 AL.01 Contact output 2 function RMT Contact output 2 operation A Selected for contact output 2.

Body Size: 20, Thread: None (Rc: for Body Size 20, 30, 40, 50, 60; M5: for Body Size 10), Port Size: 01 (1/8), Option: w/o Bracket; w/o Auto Drain, Semi-Standard 1: 6CR (6 + C + R), Semi-Standard 2: Standard

Body Size: 20, Thread: None (Rc: for Body Size 20, 30, 40, 50, 60; M5: for Body Size 10), Port Size: 01 (1/8), Option: C (N.C., Float Type Auto Drain), Semi-Standard 1: 6CR (6 + C + R), Semi-Standard 2: Standard

Body Size: 20, Thread: F (G), Port Size: 01 (1/8), Option: C (N.C., Float Type Auto Drain), Semi-Standard 1: 6CR (6 + C + R), Semi-Standard 2: Standard

Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: w/o Bracket; w/o Auto Drain, Semi-Standard 1: 6CR (6 + C + R), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: C (N.C., Float Type Auto Drain), Semi-Standard 1: 6CR (6 + C + R), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: Standard, Semi-Standard 1: 6CR (6 + C + R), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: BC (B + C), Semi-Standard 1: 6CR (6 + C + R), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

Body Size: 20, Thread: Rc, Port Size: 01 (1/8), Option: w/o Bracket; w/o Auto Drain, Semi-Standard 1: 6CR (6 + C + R), Semi-Standard 2: Standard

Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: C (N.C., Float Type Auto Drain), Semi-Standard 1: 6CR (6 + C + R), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

Body Size: 20, Thread: Rc, Port Size: 01 (1/8), Option: B (Bracket), Semi-Standard 1: 6CR (6 + C + R), Semi-Standard 2: Standard

Table 3.8-2 RTU mode message frame Address c)Function d)Data e)Checksum a)Start b)Device (CRC) f)End T1-T2-T3-T4 XX XX XX XX XX XX T1-T2-T3-T4 a) Start In Modbus RTU mode, message frames are separated by a silent interval (noncommunication time).

HRX-OM-W069-A Operation Manual Communication function Thermo-chiller Air-Cooled refrigerated type HRL100-A HRL200-A HRL300-A Keep this manual available whenever necessary 2023 SMC CORPORATION All Rights Reserved To Users, Thank you for purchasing SMCs Thermo chiller (hereinafter referred to as the product).

Body Size: 20, Thread: Rc (Rc: for Sizes 20~60; M5: for Size 10), Port Size: 02 (1/4), Mounting: None, Semi-Standard, Body Size 10: 6 (Nylon Bowl), Semi-Standard, Body Size 20: C (Bowl Guard), Semi-Standard, Body Size 30, 40, 50 & 60: R (Flow Direction: Right to Left)