An example of HRS150-A-20 "3~" stands for "3 interphase".
See Table 3-3. Use a power supply suitable for the specifications of the product. Use a power supply of over voltage category 3 (IEC60664-1)*. Be sure to connect the ground connection. Ensure that a lock out facility is availble on the power supply. Each product must have its own separate earth leakage breaker. Otherwise there can be a risk of electric shock or fire.
See Table 3-3. Use a power supply suitable for the specifications of the product. Use a power supply of over voltage category 3 (IEC60664-1)*. Be sure to connect the ground connection. Ensure that a lock out facility is availble on the power supply. Each product must have its own separate earth leakage breaker. Otherwise there can be a risk of electric shock or fire.
center 3-position exhaust center 2(B) (A)4 2(B) (A)4 (EA)5 1 (P) 3(EB) (EA)5 1 (P) 3(EB) 1 (P) 2 (B) 3 (EB) 4 (A) 5 (EA) 3-position pressure center 2(B) (A)4 (EA)5 1 (P) 3(EB) Component Parts No.
Installation environment specifications Sound noise:HRSH300-A: 71dB(A) HRSH100/150/200/250-A: 68dB(A) HRSH150/200-W: 60dB(A) HRSH100/250-W: 61dB(A) * Front 1m, height 1m, rated condition 3.2 Installation HRSH Series 3-8 HRX-OM-Q026 Chapter 3 Transport and Setting Up 3.2.5 Installation and maintenance space It is recommended to keep the space around the product shown in Fig. 3-3.
For a facility having a small installation area (that can not vent the air naturally): Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level. 3.
Setting for contact output signal 1 to 3 Detection of contact input signal Setting for alarm (AL30 and AL31) 2. Serial communication setting 3. Analog output setting 4.
3 port valve Nole) Alth IO ne a a a a a a a a a a a a a a a o a a a a a a a a a a a a a a a a a a a a a a a o a a a a a a a a a a a a a a a a o a a a a a VHS -TPressure reliel I 3-port valve PSI as unit displayed on label l/8 3/8 1/2 Nolel ) Only 1or the NPT thread Size combination Port thread Rc NPT Large knob Utilizes an oversized knob for simpe operation.
of a command is not normal. 3.12 Negative response HRS400-A-46 3-16 DOC1003626 Chapter 3 Serial communication Communication example Device Address: No.1 Read seven consecutive data from register 0100h which is out of range.
(A contact) or N.C. (B contact). Contact output signal 3 WRN alarm selects N.O. (A contact) or N.C. (B contact). (1) (2) (3) Setting of contact output signal 1 to 3 Table 5.4-28 Setting of contact output signal 1 to 3 No.
Sound noise:HRL100-A-20 : 75 dB(A) HRL200-A-20 : 75 dB(A) HRL300-A-20 : 71 dB(A) * Front 1m, height 1m, rated condition 3.2 Installation HRL Series 3-6 HRX-OM-Y098 Chapter 3 Transport and Setting Up 3.2.3 Installation and maintenance space It is recommended to keep the space around the product shown in Fig. 3-3.
Sound noise:HRL100-A-20 : 75 dB(A) HRL200-A-20 : 75 dB(A) HRL300-A-20 : 71 dB(A) * Front 1m, height 1m, rated condition 3.2 Installation HRL Series 3-6 HRX-OM-W060 Chapter 3 Transport and Setting Up 3.2.3 Installation and maintenance space It is recommended to keep the space around the product shown in Fig. 3-3.
Remove a housing from a body by rotating 4 mounting screws counterclockwise with a hexagon wrench key. Hexagon wrench key Nominal: 5 2) Remove the valve guide. Hold the valve guide with a spanner on the spanner flat to rotate it counterclockwise and remove the valve guide. Spanner Nominal: 30 3) Remove the valve spring. 4) Remove the valve assembly.
Remove a housing from a body by rotating 4 mounting screws counterclockwise with a hexagon wrench key. Hexagon wrench key Nominal: 5 2) Remove the valve guide. Hold the valve guide with a spanner on the spanner flat to rotate it counterclockwise and remove the valve guide. Spanner Nominal: 30 3) Remove the valve spring. 4) Remove the valve assembly.
Table 3-3 Power supply cable and Earth Leakage BreakerRecommended Recommended earth Terminal block leakage breaker Power screw Recomm Tighten Sensiti Rated Model supply Cable qty. x size diamet ended ing Rated vity curren voltage er crimp torque voltage of leak t terminal [V] current [A] [mA] 3 cores x10AWG HRS060-A-20 30 (3 cores x 5.5mm2) (including ground) 200, 1-phase 1.5Nm M4 5.5-4 30
2.4 Operation display panel . 2-4 Chapter 3 Transport and Setting Up . 3-1 3.1 Transport. 3-1 3.1.1 Transportation using casters . 3-2 3.2 Installation . 3-3 3.2.1 Environment . 3-4 3.2.2 Location (Required ventilation rate and facility water source) . 3-6 3.2.3 Installation and Maintenance Space . 3-7 3.3 Installation . 3-8 3.3.1 Mounting . 3-8 3.3.2 Electrical wiring . 3-9 3.3.3 Preparation
Table 3-3 Power supply cable and Earth Leakage BreakerRecommended Recommended earth leakage breaker Model Power supply Sensitivity voltage Cable qty. x size Rated Rated of leak voltage current current [V] [A] [mA] 1-phase 200-230V AC (50/60Hz) 3 cores x12AWG HRS040-A-20 200, Recomm 230 20 30 Terminal (3 cores x3.5mm2) HRS040-W-20 block ended (including ground) screw crimp diameter terminal
2.4 Operation display panel . 2-4 Chapter 3 Transport and Setting Up . 3-1 3.1 Transport. 3-1 3.1.1 Transportation using casters . 3-2 3.2 Installation . 3-3 3.2.1 Environment . 3-4 3.2.2 Location (Required ventilation rate and facility water source) . 3-6 3.2.3 Installation and Maintenance Space . 3-7 3.3 Installation . 3-8 3.3.1 Mounting . 3-8 3.3.2 Electrical wiring . 3-9 3.3.3 Preparation
2.4 Operation display panel . 2-4 Chapter 3 Transport and Setting Up . 3-1 3.1 Transport. 3-1 3.1.1 Transportation using casters . 3-2 3.2 Installation . 3-3 3.2.1 Environment . 3-4 3.2.2 Location (Required ventilation rate and facility water source) . 3-6 3.2.3 Installation and Maintenance Space . 3-7 3.3 Installation . 3-8 3.3.1 Mounting . 3-8 3.3.2 Electrical wiring . 3-9 3.3.3 Preparation
10 For Options T, MT: 15 Applicable earth leakage breaker capacity8 Rated current: 10 A For Options T, MT: 15 A Sensitivity current: 30 mA Electrical system Cable quantity x Size (Including grounding cable)15 3 cores x 14 AWG (3 cores x 2.0 mm2) Rated operating current (50/60 Hz)17 [A] 3.6/4.0 3.6/4.3 5.2/5.8 5.5/6.2 For Options T, MT 4.7/6.2 4.7/6.5 6.3/8.0 6.5/8.3 Rated power consumption