As the circulating fluid temperature is within the set range of "AS.06", "AS.06" alarm monitoring starts. Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts.
M1 05 06 N5 N6 No pressure gauge Pressure gauge with MPa display (For odd number station) Pressure gauge with MPa display (For even number station) Note 2) Pressure gauge with psi display (For odd number station) Note 2) Pressure gauge with psi display (For even number station) SY 0M P 00 5 Series 5 7 SY5000 SY7000 Regulating port Part numbers of mounting screw (For repairs) SY3000: SY3000
Case: [Resin] Polycarbonate Case, Drain Exhaust: -, Case Guard: -, Specification: Applicable part number: AL20-A, AL30-A, AL40-A, AL40-06-A, AL50-A, AL60-A, Type: Sight dome assembly
Case: -, Drain Exhaust: -, Case Guard: -, Specification: Applicable part number: AL40-A, AL40-06-A, Type: Damper holding assembly
Case: [Resin] Resin, Drain Exhaust: -, Case Guard: -, Specification: Applicable part number: AL40-A, AL40-06-A, Type: Damper (assembly)
Case: -, Drain Exhaust: -, Case Guard: -, Specification: Applicable part number: AL40-A, AL40-06-A, AL50-A, AL60-A, Type: Lubrication plug assembly
Case: [Metal] Metal case, Drain Exhaust: [Not Provided] No Drain Cock, Case Guard: With level gauge, Specification: Applicable part number: AL40-A, AL40-06-A, AL50-A, AL60-A, Type: Case assembly
Case: [Metal] Metal case, Drain Exhaust: [Manual] With Drain Cock, Case Guard: With level gauge, Specification: Applicable part number: AL40-A, AL40-06-A, AL50-A, AL60-A, Type: Case assembly
Case: [Metal] Metal case, Drain Exhaust: [Not Provided] No Drain Cock, Case Guard: None, Specification: Applicable part number: AL40-A, AL40-06-A, AL50-A, AL60-A, Type: Case assembly
Case: [Resin] Polycarbonate Case, Drain Exhaust: [Manual] With Drain Cock, Case Guard: With bowl guard, Specification: Applicable part number: AL40-A, AL40-06-A, AL50-A, AL60-A, Type: Case assembly
Case: [Resin] Polycarbonate Case, Drain Exhaust: [Manual] With Drain Cock, Barb Fitting, Case Guard: With bowl guard, Specification: Applicable part number: AL40-A, AL40-06-A, AL50-A, AL60-A, Type: Case assembly
Case: [Nylon] Nylon Case, Drain Exhaust: [Not Provided] No Drain Cock, Case Guard: With bowl guard, Specification: Applicable part number: AL40-A, AL40-06-A, AL50-A, AL60-A, Type: Case assembly
Case: [Metal] Metal case, Drain Exhaust: [Manual] With Drain Cock, Case Guard: None, Specification: Applicable part number: AL40-A, AL40-06-A, AL50-A, AL60-A, Type: Case assembly
Case: [Nylon] Nylon Case, Drain Exhaust: [Manual] With Drain Cock, Case Guard: With bowl guard, Specification: Applicable part number: AL40-A, AL40-06-A, AL50-A, AL60-A, Type: Case assembly
Case: [Nylon] Nylon Case, Drain Exhaust: [Manual] With Drain Cock, Barb Fitting, Case Guard: With bowl guard, Specification: Applicable part number: AL40-A, AL40-06-A, AL50-A, AL60-A, Type: Case assembly
Case: [Resin] Polycarbonate Case, Drain Exhaust: [Not Provided] No Drain Cock, Case Guard: With bowl guard, Specification: Applicable part number: AL40-A, AL40-06-A, AL50-A, AL60-A, Type: Case assembly
3.5.2 Precautions for communicating . 3-4 3.6 Setting method . 3-5 3.7 Communication sequence . 3-7 3.8 Message configuration . 3-7 3.8.1 Message frame . 3-7 3.9 Function code . 3-9 3.10 Checksum calculation method . 3-9 3.10.1 LRC(ASCII) . 3-9 3.10.2 CRC(RTU) .3-10 3.11 Explanation of function codes . 3-12 3.11.1 Function code: 04 Reading multiple registers .3-12 3.11.2 Function code: 06
Outside of the ambient temperature range AL36 Maintenance Maintenance alarm AL37 Refrigeration Circuit Compressor circuit failure AL38 Sensor Sensor failure AL39 Controller Controller failure AL40 Compressor Inverter Compressor inverter error AL41 Compressor Inverter Comm. Compressor inverter communication error AL42 CH1 Pump Inverter CH1 pump inverter error AL43 CH1 Pump Inverter Comm.
Size: 40 (1/2), Thread: M Thread, Rc(PT), Port Size: 06 (3/4), Accessory: B (Bracket), Option 1: 11 (1000cm³ Tank w/Switch Lower Limit OFF), Option 2: R (Flow Direction: Right->Left)
Size: 40 (1/2), Thread: M Thread, Rc(PT), Port Size: 02 (1/4), Accessory: None, Option 1: 11 (1000cm³ Tank w/Switch Lower Limit OFF), Option 2: R (Flow Direction: Right->Left)