For a facility having a large installation area (that can vent the air naturally): Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2.
For a facility having a large installation area (that can vent the air naturally): Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2.
Pressure Control Equipment Regulator O-ring Exploded view Body A Clip Industrial Filters 449 Series ARM5A/5B/5S Replacement Procedure of Diaphragm 2 2.
Pressure Control Equipment Regulator O-ring Exploded view Body A Clip Industrial Filters 449 Series ARM5A/5B/5S Replacement Procedure of Diaphragm 2 2.
For a facility with a large installation area that can vent the air naturally: Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2. For a facility with a small installation area that cannot vent the air naturally: Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level. 3.
model number HRL Series 2.1 Model Number of Product 2-1 HRX-OM-Y098 Chapter 2 Name and Function of Parts 2.2 Name and Function of Parts 2.2.1 HRL-A-20 (Air cooled type) Fig. 2-2 Names of the parts (This drawing shows HRL200-A-20.) 2.2 Name and Function of Parts HRL Series 2-2 HRX-OM-Y098 Chapter 2 Name and Function of Parts Table 2.2-1 Accessory list (1) Operation Manual 2 pcs.
of Parts 2.2 Name and Function of Parts 2.2.1 HRL-A-20 (Air cooled type) Fig. 2-2 Names of the parts (This drawing shows HRL200-A-20.) 2.2 Name and Function of Parts HRL Series 2-2 HRX-OM-W060 Chapter 2 Name and Function of Parts Table 2.2-1 Accessory list (1) Operation Manual 2 pcs.
Note HRS-S0213 Dustproof filter (Lower) 1 For HRL200-A: 2 pcs. are used per unit. HRS-S0214 Dustproof filter (Upper) 1 For HRL100/200-A: 2 pcs. are used per unit. HRS-S0185 Dustproof filter 1 For HRL300-A: 4 pcs. are used per unit.
The AL430 is a selector lubricator.
A selector lubricator is a product that selects particles of 2 μm or less from the oil mist generated in the product and supplies them to the outlet side.
The AL430 is a selector lubricator.
A selector lubricator is a product that selects particles of 2 μm or less from the oil mist generated in the product and supplies them to the outlet side.
Unpacking the sealed package Since the filter is sealed in an antistatic double bag, the inner package should be unpacked in a clean atmosphere (such as a clean room). 2. Apply a wrench to 2 chamfered flats or hexagon portion on the IN side or the OUT side to prevent the housing from rotating. 3. Always tighten threads with the proper tightening torque.
D2 D3 L1 L2 L3 L4 M1 L5 Weight T D1 H(1) D2 D3 L1 L2 L3 L4 M1 L5 H(1) A(2) A(2) AQ Weight (g) (g) Model Min.
Applicable for pressure detection with a wide range of fluids, by using a stainless steel diaphragm. 16-2-25 2 Pressure detection for a wide range of fluids.
Port size Type Cylinder side M5 x 0.8 R 1/8 R 1/4 R 3/8 R 1/2 R 1/8 R 1/4 R 3/8 R 1/2 10-32UNF NPT1/8 NPT1/4 NPT3/8 NPT1/2 Symbol M5 01 02 03 04 F01 F02 F03 F04 U10/32 N01 N02 N03 N04 Solenoid valve side M5 x 0.8 Rc 1/8 Rc 1/4 Rc 3/8 Rc 1/2 PF1/8 PF1/4 PF3/8 PF1/2 10-32UNF NPT1/8 NPT1/4 NPT3/8 NPT1/2 Elbow 2 Control type 0 1 Meter-out Meter-in SMC Pneumatics, Inc. 14 Series ASIII1F-T Dimensions
02 N02 F02 Rc1/4 Option 2 NPT1/4 None Nil G1/4 (ISO1179) Note 1) Note 1) G1/4: Applicable to ISO1179-1 With bracket Output 43 Fixed setting: NPN open collector 1 output (Pin no. 4) + PNP open collector 1 output (Pin no. 2) A 2 1 65 PNP open collector 1 output (Pin no. 4) 4 3 Note) Mounting screws are not included.
1 W Z (2 m) (2 m) + () 2 R S () () T V () () A A B B -11No.PF-OMJ0005CN-I IN OUT X693 IN OUT 73 IN OUT X694 IN OUT 73 X731 (Ar)(CO2) (ArCO2) 92:890:1080:2070:3060:40 75 / ZS-33-D 2 m () ZS-33-F ZS-33-J () ZS-33-JS () ZS-33-M () 2 ZS-33-MS () 3 ZS-33-R DIN 1 2 3 4 5 DIN F02(G1/4)DIN -12No.PF-OMJ0005CN-I LED UP) (DOWN) (OUT2) (OUT1) SET) (OUT ) (IN ) (OUT1
With gasket is provided as standard. 1/8, 1/4 standard 3/8 standard 1/2 standard Port size Symbol Cylinder side In the side of solenoid valve M5 01 M5 x 0.8 R 1/8 M5 x 0.8 Rc 1/8 Rc 1/4 Note 1) Elbow 02 R 1/4 Rc 3/8 Note 2) 03 04 F01 Rc 3/8 Rc 1/2 G 1/8 G 1/4 Note 1) R 3/8 R 1/2 R 1/8 F02 R 1/4 G 3/8 Note 2) Caution Control F03 F04 U10/32 N01 G 3/8 G 1/2 10-32 UNF NPT 1/8 NPT 1/4 Note 1)
7 A*8 201 2~200L/min 8 2 (11) S () C8 8(5/16") *6 02*1 Rc1/4 M SI*7 N02*1 NPT1/4 6 F02*1 G1/4*2 SI 1 2ISO1179-1 7:L/min :L 1 (11) L*3 3 OUT1 OU2 A NPN NPN B PNP PNP C NPN (1~5V) D NPN (4~20mA) E*4 PNP (1~5V) F*4 PNP (4~20mA) G*4 NPN *5 H*4 PNP *5 4 5 -10No.PF-OMO0004CN-E 1 W N (2 m) (2 m) + () 2 R S () () T V () () -11No.PF-OMO0004CN-E / ZS-33-D 2m ZS-33-F ZS-33-J (
Size: 1/2, Thread: G, Port Size: 1/4, Accessory: None, Option 1: Metal Bowl, Option 2: -
Min. Dripping Flow Rate(l/min): 30, Oil Storage Capacity(cm3): 135, Case: [Resin] Polycarbonate Case, Inlet Side Connection Type: G, Inlet Side Plumbing Thread Nominal: 1/4, Outlet Side Connection Type: G, Outlet Side Plumbing Thread Nominal: 1/4, Drain Exhaust: [Not Provided] No Drain Cock, Flow Direction: [Right] From Left to Right, Size of Body: 40, Accessory: Without optional