VM120-01-30 (R, B, G, Y) A-X207 VM130-01-30 (R, B, G, Y) A-X207 Panel mounting hole 40 30.5 T.T. 28.6 0.8 to 7.5 3 1.5 1.5 Symbol 2 port (A) 2 R port (3 port only) (97.3) 43.7 12 10 1 (P) (68.7) 3 port (A) 2 5.5 25 10 12 14.5 14.5 1 (P) 3 (R) * 0.5 MPa supply 25.4 2 x 1/8 44 17 2 x 4.6 mounting hole F.O.F.* 27 N T.T. 6.7 mm VM220-02-30 (R, B, G, Y) A-X207 VM230-02-30 (R, B, G, Y) A-X207 Panel
HRX-OM-Q026-V Operation Manual Installation Operation Original Instructions Thermo Chiller HRSH Series HRSH100-A-20HRSH100-A-40HRSH100-A-20-S HRSH150-A-20HRSH150-A-40HRSH150-A-20-S HRSH200-A-20HRSH200-A-40HRSH200-A-20-S HRSH250-A-20HRSH250-A-40HRSH250-A-20-S HRSH300-A-20HRSH300-A-40HRSH100-W-20HRSH100-W-40HRSH100-W-20-S HRSH150-W-20HRSH150-W-40HRSH150-W-20-S HRSH200-W-20HRSH200-W-40HRSH200
Installation at indoor site 1 In case of facility having a large installation area (that can vent the air naturally) Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2 In case of facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air
For a facility having a small installation area (that can not vent the air naturally): Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level. 3.
For a facility with a large installation area that can vent the air naturally: Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2. For a facility with a small installation area that cannot vent the air naturally: Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level. 3.
For a facility with a large installation area that can vent the air naturally: Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2. For a facility with a small installation area that can not vent the air naturally: Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level. 3.
For a facility having a small installation area (that can not vent the air naturally): Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level. 3.
CH1 r Circulating fluid flow rate It indicates the fluid flow rate. This value is not measured by a flow meter. It should be used as a reference value (rough indication).
Description Qty. r HRS-BK005 HRS100-A q Snow protection hood base 1 HRS150-A w Snow protection hood A 1 e Snow protection hood B 2 r Assembly/Mounting screw 18 72.4 in (1840 mm) 0.71 in (18 mm) Mounting condition for HRS-BK005 This hood does not completely prevent snow from entering the inside of the chiller. 22 Series HRS100/150 Cooling Capacity Calculation Required Cooling Capacity Calculation
Applicable model HRS HRS-BP008 HRS100-HRS150-HRS 090 HRS 100/150 HRS 100/150 HRSH 090 q To circulating fluid outlet To circulating fluid return port HRSH r t w y HRSE r HRZ u r HRZD t r e HRW HECR HEC Parts List HEB No. Description (The figure shows the HRS-150-A-20.)
Height 1710 x Width 1185 x Depth 955 HRSH150-Al-A 268 HRSH200-Al-A HRSH250-Al-A HRSH300-Al-A 344 Height 2020 x Width 1230 x Depth 1040 HRSH100-Wl-A 197 Height 1610 x Width 925 x Depth 955 HRSH150-Wl-A 227 HRSH200-Wl-A HRSH250-Wl-A Mounting/Installation Warning 2.
Use the bypass piping set to ensure a circulating fluid flow rate of the minimum operating flow rate or more. To circulating fluid return port Part no. Applicable model Minimum operating flow rate [L/min] HRS-BP005 HRSH090-ll-l 20 r t r e q To circulating fluid outlet r t w r Parts List No.
Use the bypass piping set to ensure a circulating fluid flow rate of the minimum operating flow rate or more. Part no. Applicable model Minimum operating flow rate (50/60 Hz) [L/min] HRS-BP005 HRS090-ll-20/40 29/45 To circulating fluid return port r t r e q To circulating fluid outlet r t w r Parts List No.
HRX-OM-W069-A Operation Manual Communication function Thermo-chiller Air-Cooled refrigerated type HRL100-A HRL200-A HRL300-A Keep this manual available whenever necessary 2023 SMC CORPORATION All Rights Reserved To Users, Thank you for purchasing SMCs Thermo chiller (hereinafter referred to as the product).
Table 3.8-2 RTU mode message frame Address c)Function d)Data e)Checksum a)Start b)Device (CRC) f)End T1-T2-T3-T4 XX XX XX XX XX XX T1-T2-T3-T4 a) Start In Modbus RTU mode, message frames are separated by a silent interval (noncommunication time).
Size: 1/2, Thread: G, Port Size: 1/2, Accessory: Bracket, Option 1: None, Option 2: Flow Direction: Right->Left
Min. Dripping Flow Rate(l/min): 50, Oil Storage Capacity(cm3): 135, Case: [Resin] Polycarbonate Case, Inlet Side Connection Type: G, Inlet Side Plumbing Thread Nominal: 1/2, Outlet Side Connection Type: G, Outlet Side Plumbing Thread Nominal: 1/2, Drain Exhaust: [Not Provided] No Drain Cock, Flow Direction: [Right] From Left to Right, Size of Body: 40, Accessory: With Bracket,
Body Size: 40, Thread: F (G), Port Size: 04 (1/2), Mounting: B (Bracket), Semi-Standard, Body Size 10: Standard, Semi-Standard, Body Size 20: Standard, Semi-Standard, Body Size 30, 40, 50 & 60: Standard
This is a legacy product, and replaced byAW40-F04B-B, FILTER REGULATOR, MODULAR, AIRLINE EQUIPMENT, AW MASS PRO, FA, AW MASS PRO 1/2 MODULAR (PT), 2.01171 lb
This is a legacy product, and replaced byVHS40-F04B, VALVE, 3 PORT LOCK OUT, VALVE, VHS HAND VALVE, J7, VHS BODY PT 1/2, 0.80883 lb