For a facility having a small installation area (that can not vent the air naturally): Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level. 3.

HRX-OM-Q026-V Operation Manual Installation Operation Original Instructions Thermo Chiller HRSH Series HRSH100-A-20HRSH100-A-40HRSH100-A-20-S HRSH150-A-20HRSH150-A-40HRSH150-A-20-S HRSH200-A-20HRSH200-A-40HRSH200-A-20-S HRSH250-A-20HRSH250-A-40HRSH250-A-20-S HRSH300-A-20HRSH300-A-40HRSH100-W-20HRSH100-W-40HRSH100-W-20-S HRSH150-W-20HRSH150-W-40HRSH150-W-20-S HRSH200-W-20HRSH200-W-40HRSH200

Remove a housing from a body by rotating 4 mounting screws counterclockwise with a hexagon wrench key. Hexagon wrench key Nominal: 5 2) Remove the valve guide. Hold the valve guide with a spanner on the spanner flat to rotate it counterclockwise and remove the valve guide. Spanner Nominal: 30 3) Remove the valve spring. 4) Remove the valve assembly.

Remove a housing from a body by rotating 4 mounting screws counterclockwise with a hexagon wrench key. Hexagon wrench key Nominal: 5 2) Remove the valve guide. Hold the valve guide with a spanner on the spanner flat to rotate it counterclockwise and remove the valve guide. Spanner Nominal: 30 3) Remove the valve spring. 4) Remove the valve assembly.

For a facility with a large installation area that can vent the air naturally: Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2. For a facility with a small installation area that cannot vent the air naturally: Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level. 3.

For a facility with a large installation area that can vent the air naturally: Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2. For a facility with a small installation area that can not vent the air naturally: Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level. 3.

For a facility having a small installation area (that can not vent the air naturally): Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level. 3.

C0.5 file chamfer AL B MM R sphere TP R sphere DC 30 H W1 T H H H Symbol: A12 Symbol: A13 Symbol: A14 Symbol: A15 30 C 30 DA DA C0.5 R sphere DA DA C AL MM 30 A H T W1 A H C A H H Symbol: A16 Symbol: A17 Symbol: A18 Symbol: A19 MM 30 MM 30 DA MM 30 AL MM 30 H A H A A C H A H Symbol: A20 Symbol: A21 Symbol: A22 Symbol: A23 DA 30 30 DA L RD 30 MM 30 MM MM DB DB T T C B A H A A A L K H W H H

Position (Standard type) Auto switch model D-Y59l D-Y69l D-Y7P D-Y7PV D-Y7H D-Y7lW D-Y7lWV D-Z7l D-Z8l D-M9l D-M9lV D-M9lW D-M9lWV D-M9lA D-M9lAV D-F5l D-J59 D-F59F D-F5NT D-A5l D-A6l D-A59W D-G39 D-K39 D-A3l D-A44 D-A9l D-A9lV D-P3DWA D-P4DW Bore size A B A B A B A B A B A B A B A B A B A B 32 10 8 6 4 6.5 4.5 11.5 9.5 0 0 4 2 0 0 3.5 1.5 5.5 3.5 3 1 40 9 9 5 5 5.5 5.5 10.5 10.5 0 0 3 3

a guide, use a solenoid valve with a large effective area for the unlocking solenoid.

Body Size: 40, Thread: F (G), Port Size: 06 (3/4), Mounting: None, Semi-Standard, Body Size 10: R (Flow Direction: Right to Left), Semi-Standard, Body Size 20: Standard, Semi-Standard, Body Size 30, 40, 50 & 60: Standard

Min. Dripping Flow Rate(l/min): 50, Oil Storage Capacity(cm3): 135, Case: [Metal] Metal case, Inlet Side Connection Type: G, Inlet Side Plumbing Thread Nominal: 3/4, Outlet Side Connection Type: G, Outlet Side Plumbing Thread Nominal: 3/4, Drain Exhaust: [Not Provided] No Drain Cock, Flow Direction: [Right] From Left to Right, Size of Body: 40, Accessory: Without optional mounting

Min. Dripping Flow Rate(l/min): 50, Oil Storage Capacity(cm3): 135, Case: [Aluminum with Level Gauge] Metal Case with Level Gauge, Inlet Side Connection Type: G, Inlet Side Plumbing Thread Nominal: 3/4, Outlet Side Connection Type: G, Outlet Side Plumbing Thread Nominal: 3/4, Drain Exhaust: [Not Provided] No Drain Cock, Flow Direction: [Right] From Left to Right, Size of Body:

Min. Dripping Flow Rate(l/min): 50, Oil Storage Capacity(cm3): 135, Case: [Resin] Polycarbonate Case, Inlet Side Connection Type: G, Inlet Side Plumbing Thread Nominal: 3/4, Outlet Side Connection Type: G, Outlet Side Plumbing Thread Nominal: 3/4, Drain Exhaust: [Not Provided] No Drain Cock, Flow Direction: [Left] From Right to Left, Size of Body: 40, Accessory: Without optional

Body Size: 40, Thread: F (G), Port Size: 06 (3/4), Mounting: None, Semi-Standard, Body Size 10: 3 (Drain Cock), Semi-Standard, Body Size 20: 6 (Nylon Bowl), Semi-Standard, Body Size 30, 40, 50 & 60: Standard

Body Size: 40, Thread: G, Port Size: 3/4, Mounting: None, Semi-Standard, Body Size 10: Drain Cock, Semi-Standard, Body Size 20: Nylon Bowl, Semi-Standard, Body Size 30, 40, 50 & 60: Standard

Body Size: 40, Thread: G, Port Size: 3/4, Mounting: None, Semi-Standard, Body Size 10: Drain Cock, Semi-Standard, Body Size 20: Standard, Semi-Standard, Body Size 30, 40, 50 & 60: Standard

Body Size: 40, Thread: G, Port Size: 3/4, Mounting: None, Semi-Standard, Body Size 10: Nylon Bowl, Semi-Standard, Body Size 20: Standard, Semi-Standard, Body Size 30, 40, 50 & 60: Standard

Body Size: 40, Thread: F (G), Port Size: 06 (3/4), Mounting: None, Semi-Standard, Body Size 10: 6 (Nylon Bowl), Semi-Standard, Body Size 20: Standard, Semi-Standard, Body Size 30, 40, 50 & 60: Standard

Body Size: 40, Thread: F (G), Port Size: 06 (3/4), Mounting: None, Semi-Standard, Body Size 10: 3 (Drain Cock), Semi-Standard, Body Size 20: Standard, Semi-Standard, Body Size 30, 40, 50 & 60: Standard