Min. Dripping Flow Rate(l/min): 50, Oil Storage Capacity(cm3): 135, Case: [Metal] Metal case, Inlet Side Connection Type: NPT, Inlet Side Plumbing Thread Nominal: 3/4, Outlet Side Connection Type: NPT, Outlet Side Plumbing Thread Nominal: 3/4, Drain Exhaust: [Not Provided] No Drain Cock, Flow Direction: [Left] From Right to Left, Size of Body: 40, Accessory: Without optional mounting
Body Size: 40, Thread: N (NPT), Port Size: 06 (3/4), Mounting: None, Semi-Standard, Body Size 10: 2 (Metal Bowl), Semi-Standard, Body Size 20: R (Flow Direction: Right to Left), Semi-Standard, Body Size 30, 40, 50 & 60: Z (Name Plate, Caution Plate for Bowl in Imperial Units: psi, °F)
FLT CH1 abnormal rise in heat exchanger inlet temperature AL40 Compressor Inverter Compressor inverter error AL18 CH1 Press. Sensor CH1 failure of circulating fluid discharge pressure sensor AL41 Compressor Inverter Comm. Compressor inverter communication error AL19 CH1 High Press.
D-G5P D-K59 D-5NTL D-H7A1 D-H7A2 D-H7B D-H7C D-G59W D-G5PW D-K59W D-G59F D-G79 D-H7PW D-H7BAL D-H7LF D-H7NF D-G5BAL D-H7PW D-H7BW 24VDC 110VAC 220VAC 24VDC 24VDC 110VAC 220VAC 24VDC 110VAC Yes/2 Wire D-B54 Yes/2 Wire D-B53 No/2 Wire D-B64 D-B73 D-C73 D-C73C D-B76 D-C76 D-B80 D-C80 D-C80C Yes/2 Wire Yes/2 Wire 20mA 4~8VDC 50mA 40mA 20mA 24V 48V 110V No/2 Wire ACCESSORIES SWITCH BANDS FOR
S E R I E S E40-N04 4000 S E R I E S E40-N06 4000 S E R I E S E60-N06 5/6000 S E R I E S E60-N10 5/6000 S E R I E S mm Model Port size A B C E10-M5 M5x0.8 16 17.5 14 E20-N01 18 E20-N02 14 23 22 22 E20-N03 38 E30-N02 14 26 34.2 29 E30-N03 38 D I M E N S I O N S P I P I N G A D A P T O R E30-N04 12 40 34.2 29 E40-N03 38 33 42.2 35 E40-N04 12 E40-N06 34 50 42.2 35 E50-N06 34 36 44 46.2 E60-
VH410-N02 to N06 3 (Closed center) 1/4" 45(2.5) 4 3 VH401-N02 to N06 VH411-N02 to N06 3 (Exhaust center) 3/8" 49(2.7) 1/2" 55(3.1) VH402-N02 to N06 VH412-N02 to N06 2 (Position) 1/4" to 3/4" 2 1 2.82 (1.28) VH4 Handle operation angle and air flow direction VH420-N02 to N06 VH430-N02 to N06 3 (Closed center) VH421-N02 to N06 VH431-N02 to N06 3 (Exhaust center) 3/4" 58(3.2) 2 position 3 position
This is a legacy product, and replaced byAF30-N03C-2RZ-A, FILTER, MODULAR, AIRLINE EQUIPMENT, AF MASS PRO, EC, AF MASS PRO 3/8 MODULAR (NPT), .61600 lb, ModelPort sizeFluidAmbient and fluid temperatureProof pressureMaximum operating pressureNominal filtration ratingDrain capacity (cm3)Bowl materialBowl guardMass (kg)AF301/4, 3/8Air?
This is a legacy product, and replaced byAW20-N02BCE-2RZ-B, FILTER REGULATOR, MODULAR, AIRLINE EQUIPMENT, AW MASS PRO, DC, AW MASS PRO 1/4 MODULAR (NPT), .92594 lb
This is a legacy product, and replaced byAF40-N02BC-2RZ-A, AF MASS PRO 1/4 MODULAR (NPT), AIRLINE EQUIPMENT, AF MASS PRO, DC, AF MASS PRO 1/4 MODULAR (NPT), 1.48521 lb, ModelPort sizeFluidAmbient and fluid temperatureProof pressureMaximum operating pressureNominal filtration ratingDrain capacity (cm3)Bowl materialBowl guardMass (kg)AF401/4, 3/8, 1/2Air?
Fig.1-3 shows the location of the communication port. 14 1 Contact input / output signal connector D sub 25 female pin (socket) type 25 13 1 6 Serial communication connector D sub 9 female pin (socket) type 9 5 Fig.1-3 Communication port HRS400-A-46 1.3 Communication port 1-5 DOC1003626 Chapter 1 Read before using 1.4 Touch panel flow Press the [Comm.
Both ends of the communication connection (the end nodes) need to be connected to the higher level computer. 2 2 R D R D 3 3 S D S D 5 5 S G S G Controller Master This product Do not connect any wire to other PIN numbers.
Both ends of the communication connection (the end nodes) need to be connected to the higher level computer. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers.
equipped as standard.) sPage 177 sPage 180 With fluid fill port 156 A Thermo-chiller Inverter Type HRSH Series Circulating Fluid Temperature Controller Circuit diagram HRSHl-W-l (Water-cooled refrigeration) HRSHl-A-l (Air-cooled refrigeration) HRS Ventilation DC inverter fan HRS 090 Water regulating valve Air release valve for facility water discharge HRS 100/150 WPR Facility water outlet D
unit only (kPa) P With unit switching function (Initial value psi) D Vacuum pressure switch *3 For q, the units for metric spec. fittings are in kPa.
Series HRS100/150 CAT.NAS40-62B R410A as refrigerant Thermo-chiller Standard Type Series HRS100/150 Circulating Fluid Temperature Controller Triple controller Fan Air-cooled condenser fan control Cooling valve Heating valve Circuit diagram Ventilation Cooling valve control Fan Facility water outlet Temperature sensor (Heat exchanger inlet) Water-cooled condenser Dryer Air-cooled condenser D
-phase 200 VAC 3-phase 400 VAC [mm] [mm]
Inverter pump Triple inverter HRZD HRW 0.6 kW 1.8 kW Water-cooled refrigeration Air-cooled refrigeration HECR 377 [mm] 970 HEC 2.4 kW HEB Triple inverter HRSH090 HED *1 Under the conditions shown on page 128 HEA Cooling capacity 9.5 kW IDH 1080 0.1C Temperature stability (when a load is stable) Set temperature range 5C to 40C W 377 x H 1080 x D 970 mm Compact, Space-saving Low-noise design
(N10), 3/4 NPT (N06) Model NAD402-N04 (N04 = 1/2 NPT) Minimum operating pressure 22psi. Maximum operating pressure 145psi.
0.5 0.5 d 1.0 1.0 d 5.0 () (mg/m 1 20,000 400 10 1 -70 1 0.01 2 400,000 6,000 100 2 -40 2 0.1 3 90,000 1,000 3 -20 3 1 4 10,000 4 +3 4 5 5 100,000 5 +7 6 +10 3.3.2 1 9 No.ZL3-OM00801-A 3.4 3.4.1 P5 (2/V) (3/E) G (1/P) 06 Rc3/4 Rc1 Rc1/8 04 Rc1/2 F06 G3/4 8() G1 G1/8 F04 G1/2 N06 NPT3/4 5/16(inch) N04 NPT1/2 NPT1 NPT1/8 3.4.2 1) 2), 3) 1 (2/V) 1 (G) 40