x 0.8 12 10 12 10 1 (P) 3 (R) 1 (P) XT34 Poppet VM200 2 port 3 port (A) 2 (A) 2 Side ported 1/4 Page 337 12 12 10 10 1 (P) 3 (R) 1 (P) VM400 3 port (OUT) 2 3 10 12 1 (N.C.)
20. 8-1 8.1.2 HRS100/150-A-40. 8-2 8.1.3 HRS100/150-A-46. 8-3 8.1.4 HRS100/150-W-20. 8-4 8.1.5 HRS100/150-W-40. 8-5 8.1.6 HRS100/150-W-46. 8-6 8.1.7 Refrigerant with GWP reference . 8-7 8.1.8 Communication specification . 8-7 8.2 Outline dimensions . 8-8 8.2.1 HRS100/150-A-20/40/46. 8-8 8.2.2 HRS100/150-W-20/40/46. 8-9 8.3 Flow diagram . 8-10 8.3.1 HRS100/150-A-20/40/46. 8-10 8.3.2 HRS100
For a facility having a small installation area (that can not vent the air naturally): Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level. 3.
Size: 3/4, Thread: M Thread, Rc(PT), Port Size: 1, Accessory: None, Option 1: Metal Bowl, Option 2: Flow Direction: Right->Left
Existing model 15 10 Heating functions are required to maintain a constant temperature particularly in the winter when the ambient temperature is low. 5 0 0 5 10 15 Time [Minute] Anti-freezing function is also available!
Cooling Capacity HRS100-A -20/40(50 Hz) HRS100-A -20/40(60 Hz) 14 14 12 12 Ambient temperature 90F (32C) Cooling capacity [kW] Cooling capacity [kW] 10 10 Ambient temperature 90F (32C) Ambient temperature 104F (40C) Ambient temperature 104F (40C) 8 8 6 6 4 4 Ambient temperature 113F (45C) Ambient temperature 113F (45C) 2 2 0 0 41 [5] 50 [10] 59 [15] 68 [20] 77 [25] 86 [30] 95 [35] 41 [5]
Cooling Capacity HRS100-A-20/40(50 Hz) HRS100-A-20/40(60 Hz) 14 14 12 12 Ambient temperature 32C Cooling capacity [kW] Cooling capacity [kW] 10 10 Ambient temperature 40C Ambient temperature 32C Ambient temperature 40C 8 8 6 6 4 4 Ambient temperature 45C Ambient temperature 45C 2 2 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [C] Circulating fluid temperature
Recommended Parameter Values [LEF] LEFS25T6 LEFS32T7 LEFS40T8 Lead symbol H A B H A B H A B Series Lead 20 12 6 24 16 8 30 20 10 Parameter *1,*2 Para. Initial value Recommended value No.
No anchor bolt is included. 77 A HRS090 Series Standard Type Cooling Capacity HRS090-A-20/40 (50 Hz) HRS090-A-20/40 (60 Hz) 12 12 10 10 Ambient temperature 32C Ambient temperature 32C Cooling capacity [kW] Cooling capacity [kW] 8 8 Ambient temperature 40C Ambient temperature 40C 6 6 4 4 Ambient temperature 45C Ambient temperature 45C 2 2 0 0 5 10 15 20 25 30 35 Circulating fluid temperature
Remote modeOpen A The time of FLT alarmClose FLT Operation stop FLT alarm status signal B The time of FLT alarmOpen A The time of WRN alarmClose WRN Continuing operation WRN alarm status signal B The time of WRN alarmOpen ALM Alarm status signal A The time of alarmClose B The time of alarmOpen RDY TEMP READY signal A TEMP READY statusClose B TEMP READY statusOpen A EnabledClose FREZ Anti-freezing
Body Size: 50, Thread: F (G), Port Size: 06 (3/4), Mounting: None, Semi-Standard, Body Size 10: 2 (Metal Bowl), Semi-Standard, Body Size 20: R (Flow Direction: Right to Left), Semi-Standard, Body Size 30, 40, 50 & 60: Standard
Body Size: 50, Thread: G, Port Size: 3/4, Mounting: None, Semi-Standard, Body Size 10: Metal Bowl, Semi-Standard, Body Size 20: Flow Direction: Right to Left, Semi-Standard, Body Size 30, 40, 50 & 60: Standard
How to measure the minimum bending radius 2R Fixed side At a temperature of 20C, bend the tubing into a U shape. Fix one end and gradually move the other end closer. Measure 2R at the point where the outside diameters rate of change is 5%.
Modular type lubricator , Improved operability , Increased capacity by reducing the thickness of resin case , Body sizes available: 10 ~ 60 , Thread type: M5, Rc(PT), NPT, G(PF) , Port sizes: M5, 1/8, 1/4, 3/8, 1/2, 3/4, 1 , Variety of options available, DAMPER ASSEMBLY AL50, AIRLINE EQUIPMENT, AL MASS PRO, 21, AL MASS PRO NO SIZE RATING, .04400 lb, ModelPort sizeFluidProof pressureMaximum
Modular type lubricator , Improved operability , Increased capacity by reducing the thickness of resin case , Body sizes available: 10 ~ 60 , Thread type: M5, Rc(PT), NPT, G(PF) , Port sizes: M5, 1/8, 1/4, 3/8, 1/2, 3/4, 1 , Variety of options available, DAMPER RETAINER ASSEMBLY AL50, AIRLINE EQUIPMENT, AL MASS PRO, 21, AL MASS PRO NO SIZE RATING, .03571 lb, ModelPort sizeFluidProof
Model Port A size Port B size No. of Port A Porting Port A Port B Model 6 8 4 8 10 12 Rc Rc 6 8 10 6, R 6, R 6, R 8, R 8, R 8, R 10, R 10, R 10, R 6 8 10 4 6 KM11 One-touch fitting One-touch fitting 6, 10 1 4 3 8 KM12 One-touch fitting Rc female thread 6, 10 KM13 One-touch fitting One-touch fitting 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main
Symbol 02 2 stations A, B P , EA, EB Symbol 04 06 Passage Porting specifications (A, B) EA, EB P 10 10 stations 1 2 Symbol 3 4 3 4 1 Side 2 Bottom M Mixed Common Common For bottom ported: 1/2 only.
Burst pressure Bend the tube into U-form at a temperature of 20C. Fix one end and close loop gradually. Measure 2R when the tube breaks or is crushed.
-10-2A Phillips' head screw SY100-33-3 M1.7 17, Non-gloss nickel plating Phillips' head screw SY100-33-2 M1.7 17, Non-gloss nickel plating Blank plate SYJ300-10-1 Blank plate SYJ300-10-1 P A Manifold gascket VJ300-5-2 A P Manifold gasket VJ300-5-1 Manifold gasket VJ300-5-2 Manifold gasket VJ300-5-1 Applicable base SS3YJ3-20 SS3YJ3-20R Applicable base sub-plate SS3YJ3-41 SS3YJ3-S41 SS3YJ3-
Then, the charging time (T) for a 100l tank, V 10 T = t x = 110 x = 110(s). 10 10 T = t x = 49 x = 49(s). 10 10 V 10 T = t x = 12.4 x = 24(s). 100 10 V 10 1.13-2 VBA1110 to 4200 Size Selection Pulsation is decreased by using tank. If secondary capacity is undersized, pulsation may occur.