SMC Corporation of America
Elite Part Number Search
Search Results "ASB2201-G02-06H"

(Response)STX01ACK][ETX][06h] Request message Response message Code Contents Code Contents 01 Slave Address 01 Slave Address W Request message to write [ACK] Normal response message STR Saves data [06h] BCC value [02h] BCC value HRS100/150 Series 5.8 Command explanation 5-21 HRX-OM-S010 Chapter 5 Simple communication protocol function 5.9 Negative response If the request is not normal when

ALM_CLR Byte Description Command Response Phases in which the command can be executed Synchronization classification Asynchronous command 1 06H 06H Phase 2 and 3 2 See (2) ALM_CLR_MO D Specifications. Processing time ALARM Subcommand Cannot be used 3 Clears the followings.

Acknowledge code ACK 06H 3-8 HEF002-A6 Communication Format 3.8 Connection (RS-485) A terminal resistance needs to be mounted on the master and slave that are placed the furthest from each other.

Acknowledge code ACK 06H 3-8 INR-244-831 Communication Format 3.8 Connection A terminal resistance needs to be mounted on the master and slave that are placed the furthest from each other.

Acknowledge code ACK 06H 7.4 Communication 7-17 A_HEC-OM-J004-4 Chapter 7 Appendix 7.4.10 Connection (for RS-485) A terminal resistance needs to be mounted on the master and slave that are placed the furthest from each other.

KK130P-06H -08H -10H -12H -07H -09H -11H -13H KK130S-06H -08H -10H -12H -07H -09H -11H -13H 6 6 Metric size mm Inch size Metric size mm Inch size 8 8 10 10 12 12 1/4" 1/4" 5/16" 5/16" 3/8" 3/8" 1/2" 1/2" Refer to the how to order on page 1 for the sleeve lock mechanism provided type.

Protocol Modbus Master / Slave Slave Letter code ASCII Slave address (Unit number) Select from 01H to 0FH Function code 03H, 06H, 10H, 17H Error check LRC method Data transfer direction LSB 5.3 Setting and checking 5.3.1 List of Items to be Set and Checked The table below explains the setting options of the MODBUS communication function.

Fault setting Class Instance Attribute Value Fault 05h 0: Fault set value 1: Output held action 09h (DOP) n (Output number+1) value 06h 0: CLEAR 1: SET Fault For details, refer to "Object mounting". -19No.EX-OME0015-F I/O memory map The SI unit occupies the memory area of 16 output points (2 bytes).

Body Size: 2 (1/8, 1/4), Control Type: 0 (Meter-out), Thread Type: G (G), Port Size: 02 (1/4), Applicable Tubing O.D.: 08 (ø8), Seal Method: without Sealant, Option: H [for General Environments, Brass Parts (External); Ni Plating]

Body Size: 2 (1/8, 1/4), Control Type: 0 (Meter-out), Thread Type: G (G), Port Size: 02 (1/4), Applicable Tubing O.D.: 10 (ø10), Seal Method: without Sealant, Option: H [for General Environments, Brass Parts (External); Ni Plating]

Body Size: 2 (1/8, 1/4), Control Type: 0 (Meter-out), Thread Type: G (G), Port Size: 02 (1/4), Applicable Tubing O.D.: 06 (ø6), Seal Method: without Sealant, Option: BH [for Welding Environments, Brass Parts (External), No Plating)

Body Size: 2 (1/8, 1/4), Control Type: 0 (Meter-out), Thread Type: G (G), Port Size: 02 (1/4), Applicable Tubing O.D.: 08 (ø8), Seal Method: without Sealant, Option: BH [for Welding Environments, Brass Parts (External), No Plating)

Body Size: 2 (1/8, 1/4), Control Type: 0 (Meter-out), Thread Type: G (G), Port Size: 02 (1/4), Applicable Tubing O.D.: 06 (ø6)

Body Size: 2 (1/8, 1/4), Control Type: 0 (Meter-out), Thread Type: G (G), Port Size: 02 (1/4), Applicable Tubing O.D.: 10 (ø10)

Body Size: 2 (1/8, 1/4), Control Type: 0 (Meter-out), Thread Type: G (G), Port Size: 02 (1/4), Applicable Tubing O.D.: 08 (ø8)

Body Size: 2 (1/8, 1/4), Control Type: 0 (Meter-out), Thread Type: G (G), Port Size: 02 (1/4), Applicable Tubing O.D.: 08 (ø8), Seal Method: w/o Sealant, Option: B (None)

Body Size: 2 (1/8, 1/4), Control Type: 0 (Meter-out), Thread Type: G (G), Port Size: 02 (1/4), Applicable Tubing O.D.: 10 (ø10), Seal Method: w/o Sealant, Option: B (None)

Body Size: 2 (1/8, 1/4), Control Type: 0 (Meter-out), Thread Type: G (G), Port Size: 02 (1/4), Applicable Tubing O.D.: 06 (ø6), Seal Method: Without Sealant, Option: D (General Environment, Brass Parts, Ni Plating)

Body Size: 2 (1/8, 1/4), Control Type: 0 (Meter-out), Thread Type: G (G), Port Size: 02 (1/4), Applicable Tubing O.D.: 08 (ø8), Seal Method: Without Sealant, Option: D (General Environment, Brass Parts, Ni Plating)

Body Size: 2 (1/8, 1/4), Control Type: 0 (Meter-out), Thread Type: G (G), Port Size: 02 (1/4), Applicable Tubing O.D.: 10 (ø10), Seal Method: Without Sealant, Option: D (General Environment, Brass Parts, Ni Plating)