SMC Corporation of America
Elite Part Number Search
Search Results "CD85F12-50-B-M9N"

Rod flange: CG1YF F FT 4 x FD FX0.15 B E 0 0.05 H B FX0.15 Head flange: CG1YG 4 x FD E 0 0.05 FX0.15 B FT F B FX0.15 ZZ + Stroke (mm) Flange Bore size (mm) B E F FX FD FT H Head flange ZZ 20 40 12 2 28 5.5 6 35 120 25 44 14 2 32 5.5 7 40 126 32 53 18 2 38 6.6 7 40 128 40 61 25 2 46 6.6 8 50 147 50 76 30 2 58 9 9 58 171 63 92 32 2 70 11 9 58 171 80 104 40 3 82 11 11 71 207 100 128 50 3 100

H 20 24 30 A 12 16 20 B 6 8 10 50 50 to to 1000 1000 Nil Without option B With lock Nil Without cable S Standard cable R Robotic cable (Flexible cable) i Actuator cable length [m] o Driver type !

Auto Switch Specifications Grommet PLC: Abbreviation of Programmable Logic Controller D-B5 (With indicator light) D-B53 D-B54 RE A B Auto switch model Applicable load PLC Relay, PLC REC Load voltage 24 VDC 24 VDC 100 VAC 200 VAC (3) Load current range 5 to 50 mA 5 to 50 mA 5 to 25 mA 5 to 12.5 mA CX Contact protection circuit None Built-in Internal voltage drop 2.4 V or less 2.4 V or less

2 L MRHQ 0 10 20 30 40 50 60 0 50 100 150 Misc.

2 L MRHQ 0 10 20 30 40 50 60 0 50 100 150 Misc.

MB B 32 50 XC89 Z MDB B 32 50 M9BW Z XC89 Built-in auto switch magnet MB B 32 50 XC91 Z MDB B 32 50 M9BW Z XC91 Built-in auto switch magnet Rod material XC91 S45C Accessories 1 Mounting B L F G C D T Nil N No bracket Pivot bracket Bore size 32 40 50 63 80 100 Basic Axial foot Rod flange Head flange Single clevis Double clevis Center trunnion Number of auto switches Auto switch 32 mm 40 mm

A B A HS 056 HS B A B A 075, 106 HS B A B A 150, 200, 250 Note 1) Figures in the table below are references for auto switch mounting positions in the stroke end detection.

Auto switch model Bore size (mm) 20 25 32 40 50 63 80 100 D-M9(V) D-M9W(V) D-A9(V) BMA3-020 (A set of a, b, c, d) BMA3-025 (A set of a, b, c, d) BMA3-032 (A set of a, b, c, d) BMA3-040 (A set of a, b, c, d) BMA3-050 (A set of a, b, c, d) BMA3-063 (A set of a, b, c, d) D-M9A(V) Note 2) BMA3-020S (A set of b, c, d, e) BMA3-025S (A set of b, c, d, e) BMA3-032S (A set of b, c, d, e) BMA3-040S

option i Cable type Symbol LEFS25 LEFS32 LEFS40 H 20 24 30 A 12 16 20 B 6 8 10 50 50 to to 1200 1200 Nil Without option B With lock Nil Without cable S Standard cable R Robotic cable (Flexible cable) o Actuator cable length [m] !

It must be mounted on the top or bottom (Fig. b). Fig. a 50 40 30 20 m Work load m [kg] m LEYG25M 10 5 4 3 2 Fig. b 1 50 40 20 30 10 5 Transfer speed [m/min] 865 LEYG Series Motorless Type * These graphs show the work load when the external guide is used together. When using the LEYG alone, refer to pages 864 and 865. * The values shown below are allowable values of the actuator body.

Lead 20: EQY25H 100 Min. 25% Max. 50% 10 20 30 40 50 90 70 80 60 0 Model EQY16 EQY25 EQY32 Lead A B C H A B C H A B C Work load [kg] 1 1.5 3 1 2.5 5 10 2 4.5 9 18 Pushing force set value [%] Ambient temperature Pushing force set value [%] Duty ratio [%] Continuous pushing time [min] 40C or less 50 or less 100 Pushing force 45% 50% 70% 42 Battery-less Absolute (Step Motor 24 VDC) Easy to

How to Order Without auto switch 50 10 T CQP2 B J79W S 50 10 T CDQP2 B With auto switch Number of auto switches Built-in magnet Auto switch 2 pcs. 1 pc. n pcs.

Applicable bore size (mm) Cylinder series 32 40 50 63 80 100 MDB1 BMP1-032 8-30-64

(Including bracket, screw) Cylinder series Applicable bore size (mm) 40 50 63 80 100 BA3 -040 BA3 -050 BA3 -063 BA3 -080 BA3 -100 CDV3, CDVS, CDL1, CE2, CNA 8-30-61 Mounting Bracket Tie-rod Mounting Style Reed switchD-Z73/Z76/Z80 Solid state switchD-Y59 /Y69 , D-Y7P(V) D-Y7NW(V)/Y7PW(V)/Y7BW(V) D-Y7BAL A B A B Hexagon socket head cap screw M4 x 0.7 x 8 l Switch mounting

(Including bracket, screw) Cylinder series Applicable bore size (mm) 40 50 63 80 100 BA3 -040 BA3 -050 BA3 -063 BA3 -080 BA3 -100 CDV3, CDVS, CDL1, CE2, CNA 8-30-61 Mounting Bracket Tie-rod Mounting Style Reed switchD-Z73/Z76/Z80 Solid state switchD-Y59 /Y69 , D-Y7P(V) D-Y7NW(V)/Y7PW(V)/Y7BW(V) D-Y7BAL A B A B Hexagon socket head cap screw M4 x 0.7 x 8 l Switch mounting

Applicable bore size (mm) Cylinder series 32 40 50 63 80 100 MDB1 BMP1-032 7-9-48

Applicable bore size (mm) Cylinder series 32 40 50 63 80 100 MDB1 BMP1-032 9-15-78

D-M9N(V)/D-M9P(V)/D-M9B(V) Direct Mounting Style . D-F8N/D-F8P/D-F8B Direct Mounting Style . D-Y59A, B /D-Y69A, B /D-Y7P(V) Direct Mounting Style . D-F9G/D-F9H Normally Closed Direct Mounting Style. D-Y7G/D-Y7H Normally Closed Direct Mounting Style. 2-color Indication Type . D-F79W/D-F7PW/D-J79W Rail Mounting Style. D-F7NWV/D-F7BWV Rail Mounting Style .

size (mm) Solid state switch D-P5DW A B HS (mm) D-P5DW Auto switch model 40, 50 A B Hs 9 7 4.5 7.5 44 50 Symbol Bore size (mm) 40 50 8 Series CQM Auto Switches/Proper Mounting Positions and Height for Stroke End Detection HS Reed switch D-A9 V Solid state switch D-F9 V D-F9 WV A B 12 HS A B 16, 20, 25 HS A B 32, 40, 50 (mm) D-F9 V, D-F9 WV D-A9 V Auto switch model Symbol A B Hs A B Hs 12

Load (N) 150 100 50 200 250 Load (N) 150 100 100 400 500 Load (N) 300 200 8-8-10 10 Precision Air Slide Table Series MXP Table Accuracy Traveling parallelism C C side parallelism to A side D M D side parallelism to B side B W A Port C MX M MTS B Distance from 0 of gauge dial when guide block is moved to full stroke after body is fixed on a base.