SMC Corporation of America
Elite Part Number Search
Search Results "CDBA2T100-175-RN-M9BL3"

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port

Magnet: D (Built-in), Series: BA2 (with End Lock), Mounting: T (Center Trunnion), Tube Material: Aluminum Tube, Bore Size: 100mm, Port Thread: Rc, Stroke: 450mm, Rod Boot: w/o Gaiter w/Cushion Both Sides, Cushion: Air Cushion, Lock Position: R (Front Lock), Release Type: N (Non-locking Type)

Magnet: D (Built-in), Series: BA2 (with End Lock), Mounting: T (Center Trunnion), Tube Material: Aluminum Tube, Bore Size: 100mm, Port Thread: Rc, Stroke: 400mm, Rod Boot: w/o Gaiter w/Cushion Both Sides, Cushion: Air Cushion, Lock Position: R (Front Lock), Release Type: N (Non-locking Type)

Magnet: Built-in, Series: with End Lock, Mounting: Center Trunnion, Tube Material: Aluminum Tube, Bore Size: 100mm, Port Thread: Rc, Stroke: 450mm, Rod Boot: w/o Gaiter w/Cushion Both Sides, Cushion: Air Cushion, Lock Position: Front Lock, Release Type: Non-locking Type, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Series: with End Lock, Mounting: Center Trunnion, Tube Material: Aluminum Tube, Bore Size: 100mm, Port Thread: Rc, Stroke: 400mm, Rod Boot: w/o Gaiter w/Cushion Both Sides, Cushion: Air Cushion, Lock Position: Front Lock, Release Type: Non-locking Type, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, TIE ROD, END LOCK, ACTUATOR, CBA1/CBA2 TIE-ROD CYL END LOCK, SC, CBA1 100MM OTHERS (COMBO), 28.26325 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, TIE ROD, END LOCK, ACTUATOR, CBA1/CBA2 TIE-ROD CYL END LOCK, SC, CBA1 100MM OTHERS (COMBO), 29.10101 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, TIE ROD, END LOCK, ACTUATOR, CBA1/CBA2 TIE-ROD CYL END LOCK, SC, CBA1 100MM OTHERS (COMBO), 28.26325 lb

Air cylinder series CA2 has been introduced with specifications and dimensions equivalent to the existing CA1 series. Several improvements have been made to the CA2 series including lateral load improvement, increase in cushioning capacity and adoption of a new cushion seal. There has been enhanced efficiency in handling for cushion valve adjustment, and weight has been reduced by 5 to 15%

Air cylinder series CA2 has been introduced with specifications and dimensions equivalent to the existing CA1 series. Several improvements have been made to the CA2 series including lateral load improvement, increase in cushioning capacity and adoption of a new cushion seal. There has been enhanced efficiency in handling for cushion valve adjustment, and weight has been reduced by 5 to 15%

Air cylinder series CA2 has been introduced with specifications and dimensions equivalent to the existing CA1 series. Several improvements have been made to the CA2 series including lateral load improvement, increase in cushioning capacity and adoption of a new cushion seal. There has been enhanced efficiency in handling for cushion valve adjustment, and weight has been reduced by 5 to 15%

-c" urrent -;:--nge O I-road c t + ---_ In _t _ e_ rn _a _l _v _ o _ lt _ a ,, 9 ,, e_d _'_ 0 cP _ _ + _ ~ 0 I 2AVOf~ __ -Leak current 0 Response time 1.2 ms COJPB6-1OD _ In _d _ ic c.a :.. t_ o_ , _ Ia _ m ..: p _ _ + __ .---!'

To enable the run/stop signal input or remote signal input, after wiring, set the item "Contact input signal 1 function selection" in "Communication setting menu" from "OFF (initial setting value)" to "RN .ST ". Tips This product has two input signals. These can be customized depending on the customers application. 1. Prepare a suitable connector cable. 2.

To enable the run/stop signal input or remote signal input, after wiring, set the item "Contact input signal 1 function selection" in "Communication setting menu" from "OFF (initial setting value)" to "RN .ST ". Tips This product has two input signals. These can be customized depending on the customers application. 1. Prepare a suitable connector cable. 2.

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: -, Valves: -, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in

Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: Ø50 mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 100mm, Body Option: CM (Rubber Bumper, Rod End Male Thread), Lock Position: R (Front Lock), Release of Manual: N (Non-locking Type), Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3 m), Number: 3

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: -, Valves: -, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 175, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Without magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 175, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 175, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port thread type: Rc,