This is a legacy product, and replaced byCDG1BA32-400Z, CYL, AIR, ACTUATOR, CG/CG3 ROUND BODY CYLINDER, LE, 32MM CG DBL-ACT AUTO-SW, 2.51124 lb
This is a legacy product, and replaced byCDG1BN40-400Z, CYL, AIR, ACTUATOR, CG/CG3 ROUND BODY CYLINDER, ME, 40MM CG DBL-ACT AUTO-SW, 3.82195 lb
This is a legacy product, and replaced byCA2D40-400Z, CYL, TIE ROD, NON-LUBE, ACTUATOR, CA1/CA2 TIE-ROD CYLINDER, MD, 40MM CA1 DOUBLE-ACTING, 5.77860 lb
This is a legacy product, and replaced byCA2L50TN-400Z, CYL, TIE ROD, NON-LUBE, ACTUATOR, CA1/CA2 TIE-ROD CYLINDER, ND, 50MM CA1 DOUBLE-ACTING, 4.18878 lb
This is a legacy product, and replaced byCDA2YT50TN-400Z CA2Y SMOOTH CYLINDER. 50MM CA2Y DBL-ACT AUTO-SW. ACTUATOR. 50MM CA2Y DBL-ACT AUTO-SW. 9.2594 lb. NE.
This is a legacy product, and replaced byCDM2B25-400Z CM2/CM3 ROUND BODY CYLINDER. CYLINDER. ACTUATOR. 25MM CM2 DBL-ACT AUTO-SW. 1.433 lb. IE.
Magnet: D (Built-in Magnet), Mounting: B (Basic), Type: A (Air Cushion), Bore: 40mm, Port Thread Type: Rc (or M5, Depending on Style, Bore Size, and Thread Combination), Stroke: 400mm, Thread: Male Rod End, Suffix for Cylinder: w/o Rod Boot
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: A93, Lead Wire Length
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: B53, Lead Wire Length
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: H7BW, Lead Wire Length
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9B, Lead Wire Length
Magnet: D (Built-in Magnet), Mounting: B (Basic), Type: A (Air Cushion), Bore: 40mm, Port Thread Type: Rc (or M5, Depending on Style, Bore Size, and Thread Combination), Stroke: 400mm, Thread: Male Rod End, Suffix for Cylinder: w/o Rod Boot, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal
Magnet: D (Built-in Magnet), Mounting: B (Basic), Type: A (Air Cushion), Bore: 40mm, Port Thread Type: Rc (or M5, Depending on Style, Bore Size, and Thread Combination), Stroke: 400mm, Thread: Male Rod End, Suffix for Cylinder: w/o Rod Boot, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: A93, Lead Wire Length
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: B53, Lead Wire Length
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: H7BW, Lead Wire Length
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9B, Lead Wire Length
Magnet: D (Built-in Magnet), Mounting: B (Basic), Type: A (Air Cushion), Bore: 40mm, Port Thread Type: Rc (or M5, Depending on Style, Bore Size, and Thread Combination), Stroke: 400mm, Thread: Male Rod End, Suffix for Cylinder: w/o Rod Boot, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewire Connection: 0.5m (Or None in the Case of No Switch), Number: