SMC Corporation of America
Elite Part Number Search
Search Results "CDG5BA32SV-350-G5BAL"

~ 500 14 88 32 350 ~ 600 14 90 40 350 ~ 800 15 101 50 350 ~ 1000 16 116 63 350 ~ 1100 16 119 80 350 ~ 1200 23 145 100 350 ~ 1300 23 145 B R A C K E T M O U N T I N G S T R O K E Bore Size (mm) Bracket Mounting Stroke 20 100st or more 25 125st or more 32 150st or more 40 200st or more 50 250st or more 63 300st or more 80 400st or more 100 500st or more Bore Size Stroke range (mm) A AA AB

Standard Stroke Bore size (mm) Standard stroke (mm) 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 50, 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 80, 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 Max.

, 400 MGCM Slide bearing 350, 400, 450, 500 350, 400, 450, 500, 600 75, 100, 125, 150, 350, 400, 450, 500, 600, 700, 800 200, 250, 300 MGCL Ball bushing baering 350, 400, 450, 500, 600, 700, 800, 900, 1000 *Short stroke or intermediate stroke(except above stroke): Manufactured upon receipt of order 3.20-2 Compact Guide Cylinder Series MGC Specifications MGCll20 MGCll25 MGCll32 MGCll40 MGCll50

to 500 207 14 146 350 to 600 210 14 146 350 to 800 236 15 191 Note) Dimensions marked with "*" are not required for back plate non attached style.

BBA3: D-B5/B6/G5 types BBA4: D-C7/C8/H7 types "D-G5BAL" and "D-H7BAL"switches are set on the cylinder with the screws above when shipped. When a switch only is shipped, BBA3 or "BBA4" screws are attached.

Type N A Non-lube, rubber bumper Non-lube, air cushion Auto switch type/Band mount type Bore size Nil G5BAL Without auto switch (built-in magnet) 50 63 80 100 20 25 32 40 50mm 63mm 80mm 100mm 20mm 25mm 32mm 40mm D-G5BAL (water resistant) D-G5BASAPC (water resistant) 3 pin M8 connector, 0.5M lead G5BASAPC Auto switches are available in the band mount type only.

to 500 162 14 170 32 32 106 12 38 20 138 84 62 37 3 228 M8 x 1.25 depth 13 35.5 82 350 to 600 165 14 173 40 40 116 12 47 25 164 94 75 44 4 274 M10 x 1.5 depth 16 40 93 350 to 800 183 15 192 6-17-112 92 Made to Order Common Specifications: -XC74: With Front Plate for MGG Cylinder Symbol -XC74 50 With Front Plate for MGG Cylinder Type using MGG cylinders standard front plate.

CL-40 CL-50 CL-63 CL-80 CL-100 Standard Stroke Bore size (mm) Standard stroke (mm) 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 50, 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 80, 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 Maximum Stroke For the maximum stroke of the CA1 series 40 to 100, and CS1 series

CL-40 CL-50 CL-63 CL-80 CL-100 Standard Stroke Bore size (mm) Standard stroke (mm) 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 50, 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 80, 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 Maximum Stroke For the maximum stroke of the CA1 series 40 to 100, and CS1 series

However, the standard length for G5NTL, G5BAL, F5NTL and F5BAL is 3m.

Contact P/A in this case. 1 Guide Cylinder Series MGG Models and Specifications JIS symbol Models and strokes Long stroke (mm) Standard stroke (mm) Model Bearing type Bore size (mm) 20 250, 300, 350, 400 75, 100, 125, 150, 200 25 350, 400, 450, 500 MGGM Slide bearing 32 350, 400, 450, 500, 600 40 350, 400, 450, 500, 600, 700, 800 75, 100, 125, 150, 50 350, 400, 450, 500, 600, 700, 800, 900

, 400, 450, 500 1000 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 1000 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 1000 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 1000 80 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 1000 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300

with M5 thread Flow direction: Right to left With element service indicator Size 1/8 1/4 3/8 1/2 3/4 1 1 1/2 2 01 02 03 04 06 10 14 20 2B, 150 4B, 250 8B, 350 11B, 450 22B, 550 37B, 650 75B, 850 Rc NPT G 1/8 1/4 3/8 1/2 3/4 1 1 1/2 Nil J M R T Nil B C D Option Accessory Size Bore size RT T R JR JRT MR J MRT JT MT M 03 06 04 01 02 20 14 Size 10 2B, 150 4B, 250 8B, 350 11B, 450 22B, 550 37B

Water Resistant Z R Rod end thread CDG1 Stroke Auto switch Port thread type Bore size Type Mounting type Pivot bracket Rod end bracket Water resistant 2-color indicator, solid state auto switch Nil Without magnet D Built-in magnet Water resistant cylinder M9A(V) 32 to 63 G5BAL 80, 100 R NBR seals (Nitrile rubber) V FKM seals (Fluororubber) Made to Order XC6 Specifications Since the scraper

BBA3: For D-B5/B6/G5/K5 D-G5BAL is mounted on the cylinder with the above stainless steel screw BBA3 before shipment or BBA3 is enclosed with D-G5BAL when shipped without cylinder.

Auto Switch Specifications Grommet Water (coolant) resistant type PLC: Abbreviation of Programmable Logic Controller D-G5BAL (With indicator light) RE A B D-G5BAL Auto switch model 2-wire Wiring type REC Output type 24 VDC Relay, PLC Applicable load CX Power supply voltage Current consumption CY 24 VDC (10 to 28 VDC) Load voltage 5 to 40 mA Load current MQQ M Courtesy of Steven Engineering

BBA3: For D-B5/B6/G5 BBA4: For D-C7/C8/H7 D-G5BAL and D-H7BAL switches are set on the cylinder with the stainless steel screws above when shipped.

Auto Switch Specifications Grommet Water (coolant) resistant type PLC: Abbreviation of Programmable Logic Controller D-G5BAL (With indicator light) CJ1 D-G5BAL Auto switch model 2-wire Wiring type CJP Output type 24 VDC Relay, PLC Applicable load CJ2 Power supply voltage Current consumption CM2 24 VDC (10 to 28 VDC) Load voltage 5 to 40 mA Load current CG1 Courtesy of Steven Engineering

Auto Switch Specifications Grommet Water (coolant) resistant type PLC: Abbreviation of Programmable Logic Controller D-G5BAL (With indicator light) D-G5BAL MX Auto switch model 2-wire Wiring type MTS Output type 24 VDC Relay, PLC Applicable load MY Power supply voltage Current consumption CY 24 VDC (10 to 28 VDC) Load voltage 5 to 40 mA Load current MG Courtesy of Steven Engineering, Inc

Auto Switch Specifications Grommet Water (coolant) resistant type PLC: Abbreviation of Programmable Logic Controller D-G5BAL (With indicator light) CL D-G5BAL Auto switch model 2-wire Wiring type CL1 Output type 24 VDC Relay, PLC Applicable load MLGC Power supply voltage Current consumption CNG 24 VDC (10 to 28 VDC) Load voltage 5 to 40 mA Load current MNB Courtesy of Steven Engineering