, 450, 500 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 80 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 Fluid Air Proof Ppressure 1.5MPa / 214PSI Max Operating Pressure 1.52MPa
, 450, 500 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 80 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 Fluid Air Proof Ppressure 1.5MPa / 214PSI Max Operating Pressure 1.52MPa
Standard Stroke Bore size (mm) Standard stroke (mm) 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 50, 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 80, 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 Max.
BBA3: For D-B5/B6/G5 BBA4: For D-C7/C8/H7 D-G5BAL and D-H7BAL switches are set on the cylinder with the stainless steel screws above when shipped.
However, the standard length for G5NTL, G5BAL, F5NTL and F5BAL is 3m.
However, the standard length for G5NTL, G5BAL, F5NTL and F5BAL is 3m. Note 3) Cannot be mounted on cylinders with 32 bore size.
MGCM Slide bearing 350, 400, 450, 500 350, 400, 450, 500, 600 75, 100, 125, 150, 350, 400, 450, 500, 600, 700, 800 200, 250, 300 MGCL Ball bushing baering 350, 400, 450, 500, 600, 700, 800, 900, 1000 *Short stroke or intermediate stroke(except above stroke): Manufactured upon receipt of order 3.20-2 Compact Guide Cylinder Series MGC Specifications MGCll20 MGCll25 MGCll32 MGCll40 MGCll50
BBA3: D-B5/B6/G5 types BBA4: D-C7/C8/H7 types "D-G5BAL" and "D-H7BAL"switches are set on the cylinder with the screws above when shipped. When a switch only is shipped, BBA3 or "BBA4" screws are attached.
Both directions Lock direction MXW MXP Stroke Bearing Standard stroke (mm) Long stroke (mm) Bore size (mm) MG Model MGP 20 75, 100, 125, 150, 200 250, 300, 350, 400 MLGCM Slide bearing 25 350, 400, 450, 500 MGQ 75, 100, 125, 150, 32 350, 400, 450, 500, 600 MLGCL Ball bushing bearing 200, 250, 300 40 350, 400, 450, 500, 600, 700, 800 MGG * Middle strokes and short strokes other than shown
Type N A Non-lube, rubber bumper Non-lube, air cushion Auto switch type/Band mount type Bore size Nil G5BAL Without auto switch (built-in magnet) 50 63 80 100 20 25 32 40 50mm 63mm 80mm 100mm 20mm 25mm 32mm 40mm D-G5BAL (water resistant) D-G5BASAPC (water resistant) 3 pin M8 connector, 0.5M lead G5BASAPC Auto switches are available in the band mount type only.
CL-40 CL-50 CL-63 CL-80 CL-100 Standard Stroke Bore size (mm) Standard stroke (mm) 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 50, 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 80, 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 Maximum Stroke For the maximum stroke of the CA1 series 40 to 100, and CS1 series
CL-40 CL-50 CL-63 CL-80 CL-100 Standard Stroke Bore size (mm) Standard stroke (mm) 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 50, 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 80, 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 Maximum Stroke For the maximum stroke of the CA1 series 40 to 100, and CS1 series
But, for MGQ80, 100 and MGP80, 100, it will be 50 to 400 mm/s. 50 to 200 mm/s for Series MK. Please contact SMC for operating speed of Series CY1B. Note 5) Please contact SMC for Series CQ2 and MGQ with rubber bumper.
To use the system in a magnetic field that exceeds this value, use a magnetic material to shield the sensor unit. 63 50 50 40 40 YES 100 200 300 400 500 100 200 300 400 500 NO Does the mounted load exceed the load given in the diagram? Piston speed (mm/s) Horizontal mounting Piston speed (mm/s) Vertical mounting Selection O.K.
KNK-10-600 KNK-12-400 KNK-12-600 KNK-16-400 KNK-16-600 KNK-20-400 KNK-20-600 35 D 8.5 H2 L2 L1 Pivoting nozzle with male thread/KNK (mm) Model Nozzle size D Connection size L1 A Width across flats H1 H2 Connection thread 4 6 4 6 4 6 R 1/4 R 1/4 R 3/8 R 3/8 R 1/2 R 1/2 17 17 17 17 17 17 17 17 17 17 22 22 38 38 39 39 42.2 42.2 31.9 31.9 32.4 32.4 34.1 34.1 KNK-R02-400 KNK-R02-600 KNK-R03
Contact P/A in this case. 1 Guide Cylinder Series MGG Models and Specifications JIS symbol Models and strokes Long stroke (mm) Standard stroke (mm) Model Bearing type Bore size (mm) 20 250, 300, 350, 400 75, 100, 125, 150, 200 25 350, 400, 450, 500 MGGM Slide bearing 32 350, 400, 450, 500, 600 40 350, 400, 450, 500, 600, 700, 800 75, 100, 125, 150, 50 350, 400, 450, 500, 600, 700, 800, 900
3000 3000 CLQ 2000 2000 MLGP 160 140 RLQ 1000 1000 Load weight: m (kg) Load weight: m (kg) 700 800 900 700 800 900 125 MLU 600 600 160 500 500 ML1C 400 400 140 320 125 300 300 D200 200 -X 280 20100 100 100 500 400 300 200 100 500 400 300 200 Data Maximum speed: V (mm/s) Maximum speed: V (mm/s) Graph (7) Graph (4) 0.5 MPa P 0.5 MPa P 3000 3000 2000 2000 160 140 125 1000 1000 Load weight:
, 450, 500 1000 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 1000 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 1000 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 1000 80 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 1000 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350
Piston speed Caution The cylinder speed upper limit that retains the particle generation grade is 400 mm/s. Back matter 5 Clean series: Common Precautions 3 Be sure to read before handling. Refer to the main text for detailed precautions for every series.
Piston speed Caution The cylinder speed upper limit that retains the particle generation grade is 400 mm/s. Back matter 5 Clean series: Common Precautions 3 Be sure to read before handling. Refer to the main text for detailed precautions for every series.