Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Magnet: D (Built-in), Mounting: D (Clevis), Bore Size: Ø10 mm, Stroke: 40 mm
Unit Series AC20D to 40D Dimensions AC20D A F N E P K C G G IN OUT Q F.R.L.
Description Material MHW2-20D MHW2-25D MHW2-32D MHW2-40D MHW2-50D !6 !7 !8 !
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: M9P, Lead
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: M9P, Lead
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: M9P, Lead
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 35, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: M9P,
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: M9P, Lead
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: M9P, Lead
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: M9P, Lead
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 35, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: M9P,
Magnet: D (Built-in), Mounting: D (Clevis), Bore Size: Ø10 mm, Stroke: 30 mm, Rod End Thread: With Thread, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)
Magnet: D (Built-in), Mounting: D (Clevis), Bore Size: Ø10 mm, Stroke: 20 mm, Rod End Thread: With Thread, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)
Magnet: D (Built-in), Mounting: D (Clevis), Bore Size: Ø10 mm, Stroke: 15 mm, Rod End Thread: With Thread, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)
Magnet: D (Built-in), Mounting: D (Clevis), Bore Size: Ø10 mm, Stroke: 35 mm, Rod End Thread: With Thread, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)
Rod side mounting/Without auto switch Head side mounting/Without auto switch C D Mounting bolt Model C D Mounting bolt Model CQSB12-5D -10D -15D -20D -25D -30D CQSB16-5D -10D -15D -20D -25D -30D CQSB20-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D CQSB25-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D CQSB12-5D -10D -15D -20D -25D -30D CQSB16-5D -10D -15D -20D -25D -30D CQSB20-5D -10D -
model S D-Y7W(V) D-Y59 D-Y69 D-Y7P(V) 1 Red light at ON Greeen light at ON MHW2-20D MHW2-25D MHW2-32D MHW2-40D MHW2-50D 4 4 13 4 4 10 2 2 7 2 2 5 2 2 4 12-10-24
CQSWB125D 10D 15D 20D 25D 30D CQSWB165D 10D 15D 20D 25D 30D CQSWB205D 10D 15D 20D CQSWB2025D 30D 35D 40D 45D 50D CQSWB255D 10D 15D 20D 25D 30D 35D 40D 45D 50D 6.5 10 6.5 7 10 Note) Appropriate plain washer must be used for through-hole mounting.