SMC Corporation of America
Elite Part Number Search
Search Results "CDLA2F100TN-300N-P-M9PWV"

Note 4) Always use line receivers to receive the output signals. * The functions allocated to the input signals /DEC, P-OT, N-OT, /EXT1, /EXT2 and /EXT3, and the output signals /SO1, /SO2 and /SO3 can be changed by setting the parameters.

Bore size (mm) Y NN P S X ZZ 20 M22 x 1.5 1/8 81 20 9 151 25 M24 x 1.5 1/8 81 20 9 156 32 M30 x 1.5 1/8 87 23 9 172 40 M33 x 2 1/4 108 25 11 198 320 Round Type Hydraulic Cylinder: 3.5 MPa CHM Series Rod flange type: CHMF Width across flats B2 CHQ Width across flats B1 CHK N GA GB Rc P N Rc P 4 x FD H1 H2 2 x NN CHN CHM CHM I IA D FY B CHS MM Effective thread CH2 K F NB Width across flats

1/2 77 60 17 80 133 168 100 25 to 1000 14.5 M42 x 2 58 42 15 257.5 M14 x 1.5 56 115 52 90 56 86 16 50 41 38 19 3/4 79 72 22 97 146 187 Transaxial foot: CHSDLA PJ + Stroke Y J MM S + Stroke H B 2 x RcP GB GA Air release LY D E V V LH LT X1 X2 K F Y1 Cushion valve G C M Y2 MA ZA + Stroke SS BB LX 4 x CD Z + Stroke A ZZ + Stroke Stroke range Bore size (mm) BB CD E F GA GB H M J LH LT LX LY P

Lead wire length (m) Load voltage Auto switch model Electrical entry direction Indicator light Type Electrical entry Pre-wired connector Wiring (output) Special function Applicable load 0.5 (Nil) 1 (M) 3 (L) 5 (Z) AC DC Perpendicular In-line M9NV M9PV M9BV M9NWV M9PWV M9BWV M9NAV1 3-wire (NPN) M9N M9P M9B M9NW M9PW M9BW M9NA1 5 V, 12 V IC circuit Reed auto switch Solid state auto switch 3

Stroke Reading Cylinder and Counter CE Series CEP1 CEP1 CE1 CE1 CE2 CEP1/CEU5 Resolution: 0.01 mm (Accuracy 0.02 mm) Output function: RS-232C BCD Output: 5 points (Bank switching: 20 points) 31 points (Binary output) ML2B High Precision Stroke Reading Cylinder CEP1 Series 12, 20 Stroke Reading Cylinder CE1 Series 12, 20, 32, 40 50, 63 Multi-counter CEU5 Series DP.647 P.656 P.667 -X 641 Air

P IP65 equivalent (Dust-tight/Water-jet-proof)/ With vent hole tap Nil Ends tapped/ Body bottom tapped 2 V V When using the dust-tight/water-jet-proof (lP65 equivalent), correctly mount the fitting and tubing to the vent hole tap, and then place the end of the tubing in an area not exposed to dust or water. The fitting and tubing should be provided separately by user.

Lead wire length (m) 0.5 (Nil) 1 (M) 3 (L) 5 (Z) Load voltage Auto switch model Indicator light Type Electrical entry Wiring (output) Special function Perpendicular In-line Pre-wired Applicable load None (N) connector AC DC M9N M9P M9B M9NV M9PV M9BV J79C M9NWV M9PWV M9BWV M9NAV1 3-wire (NPN) IC circuit 5 V, 12 V 3-wire (PNP) Grommet Reed auto switch Solid state auto switch 12 V 2-wire Connector

Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 100mm, Thread: TN (NPT), Stroke: 150mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: P (Air Pressure Lock-up)

Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 100mm, Thread: TN (NPT), Stroke: 800mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: P (Air Pressure Lock-up)

Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 100mm, Thread: TN (NPT), Stroke: 200mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: P (Air Pressure Lock-up)

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 100mm, Thread: NPT, Stroke: 150mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Air Pressure Lock-up, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 100mm, Thread: NPT, Stroke: 800mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Air Pressure Lock-up, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 100mm, Thread: NPT, Stroke: 200mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Air Pressure Lock-up, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.08 to 1.0, Specification: Built-in magnet

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.08 to 1.0, Specification: Built-in magnet

Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 80mm, Thread: TN (NPT), Stroke: 300mm, Option: N [w/o Rod Boot, w/o Cushion (Not Valid for Air-hydro), Lock Operation: P (Air Pressure Lock-up)

Magnet: D (Built-in), Mounting: B (Basic Style), Style: Aluminum Tube, Bore Size: 100mm, Thread: TN (NPT), Stroke: 300mm, Option: N [w/o Rod Boot, w/o Cushion (Not Valid for Air-hydro), Lock Operation: P (Air Pressure Lock-up)

Magnet: D (Built-in), Mounting: B (Basic Style), Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 300mm, Option: N [w/o Rod Boot, w/o Cushion (Not Valid for Air-hydro), Lock Operation: P (Air Pressure Lock-up)

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.08 to 1.0, Specification: Built-in magnet

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.08 to 1.0, Specification: Built-in magnet