Z 11 Lead wire min. bending radius 10 Auto switch D-A7, A8 K M E S J B + Stroke A + Stroke L Rod end male thread H1 Rod end nut C1 X L1 Rod End Male Thread (mm) Bore size (mm) 63 Auto switch D-A9, F9 C1 X H1 L1 26 28.5 M18 x 1.5 33.5 80 32.5 35.5 M22 x 1.5 43.5 100 32.5 35.5 M26 x 1.5 43.5 (mm) Without auto switchWith auto switch Bore size (mm) Stroke range (mm) C D E F H I J K L M N O P
63 80 100 MGTL D-Y5 type D-Z7 type Note 1) Note 1) D-Z8 type D-A9 type D-F9 type D-Y6 type D-Y7 type Note 1) Vertical outlet types cannot be mounted.
F9NV F9PV 154 154 154 Long Stroke Slide Table MXW Series 2 color indication solid state switch: D-F9BW (V), D-F9NW (V), D-F9PW (V) Switch operation range Stroke (mm) Model 25 50 75 100 125 150 175 200 225 250 275 300 A 49.5 28.5 24.5 24.5 24.5 24.5 B 82.5 103.5 128.5 153.5 178.5 203.5 4 MXW 8 W 35.5 14.5 10.5 10.5 10.5 10.5 V 96.5 117.5 142.5 167.5 192.5 217.5 A 48 28 28 28 28 B 107
1) D-Z8 type D-A9 type D-F9 type D-Y6 type Ball bushing D-Y7 type Note 1) Vertical outlet types cannot be mounted.
/C8 D-C73C/C80C D-B5/B6 D-B59W D-A3/A4 D-A3A/A44A D-A3C/A44C D-A7/A8 D-A7H/A80H D-A73C/A80C D-A79W D-A5/A6 D-A59W D-A9 D-A9V D-Z7/Z8 D-H7 D-H7C D-H7BAL D-H7F D-H7W D-G5/K5 D-G5BAL D-G59F D-G5NTL D-G5W/K59W D-G39/K39 D-G39A/K39A D-F7/J7 D-J79C D-F7F D-F7BAL D-F7BAVL D-F7V D-F7NTL D-F7W (V) D-F5/J5 D-F5BAL D-F5W/J59W D-F5F D-F5NTL D-G39C/K39C D-M9 D-M9V D-F9W D-F9WV D-F9BAL D-Y59A/Y7P/Y59B
Minimum Stroke for Auto Switch Mounting (mm) Applicable auto switch model No. of auto switches mounted D-A9 D-A9V D-M9 D-M9V D-F9W D-F9WV 1 pc. 5 5 5 2 pcs. 10 10 5 Auto switch model Bore size (mm) Operating Range 6 5 10 6 16 9 D-A9/A9V 3 (2) 3.5 (2) 5.5 (3) D-M9/M9V D-F9W/F9WV Since this is a guideline including hysteresis, not meant to be guaranteed.
D-A9V D-M9V D-F9WV ( ): Denotes the values of D-M9V, D-F9WV.
Wiring Electrical entry Auto switch type Electrical entry from inside 3-wire D-F9P B Solid state switch D-F9 In-line 2-wire D-F9B 3-wire D-F9NW,D-F9PW In-line 2 color indication solid state switch D-F9 W 2-wire D-F9BW 3-wire D-F9NWV,D-F9PWV Perpendicular B 2-wire D-F9BWV Install auto switch as shown in figure below.
Shock absorber specifications cannot be changed by replacing or adding parts. 50 to 500 80 245 80 245 10 to 60 1.96 3.83 15 1.96 4.22 15 Spring force N Extended Compressed Weight g Minimum Strokes for Auto Switch Mounting (mm) Applicable auto switch models Number of auto switches mounted 1 pc. 2 pcs. 5 10 5 10 5 5 D-A9, D-A9V D-F9, D-F9V D-F9W, D-F9WV D-F9BA 2 Series MXP Table Deflection
Auto switches / Proper mounting position for stroke end detection Electrical entry direction: Inward Electrical entry direction: Outward B D C A (mm) D-Z73 D-Y59A,D-Y59B A B C D Bore size D 0.5 4 0.5 3 5 5 C 16.5 23 34 46 46.5 56 6 20.5 27 38 50 50.5 60 -1 2.5 -1 1.5 3.5 3.5 32 15 21.5 32.5 44.5 45 54.5 4.5 8 4.5 7 8.5 9 10 15 20 25 Note 1) The above mentioned values are indicated as a guide
For D-A93, only outward electrical entry (D dimension) is available. Dimensions in parentheses apply to 12-CXSJ6. CXSJ10 / CXSJ10 11122122Note 2) D B Note 3) (mm) D-M9 34 (35.5) 3.5 (2) 24 (25.5) 6.5 (8) D-A93 30 (31.5) 25.5 (27) 5 (6.5) Symbol A B C D Note 1) The above mentioned values are indicated as a guide for auto switch mounting positions for stroke end detection.
freezing) Bearing type Ball spline Rubber bumper Cushion Air cushion Effective cushion length (mm) 11 12 9 10 17 17 Lubrication Non-lube Reed switch: D-A9 Solid state switch: D-F9 D-F8 Reed switch: D-A9 Solid state switch: D-F9 Auto switches +1.0 0 Stroke tolerance mm 0.1 or less (within allowable torque values) 0.2 or less (within allowable torque values) Non-rotating accuracy Port size
, D-F9WV D-M9, D-F9W D-M9V D-A9V D-F9BAL CQ2 No. of auto switches mounted 1.
D-A9l, D-F9lWV D-F9 , D-F9lW D-F9N B P D-A9lV D-F9lV D-F9BA No. of auto switches 15 20 25 10 10 5 2 10 15 20 25 5 5 1 Consult SMC for shorter strokes than indicated in the table.
, D-F9WV D-F9P B, D-F9W D-A9V D-F9N D-F9V Number of auto switches 2 pcs. 15 (0.6) Note) 20 (0.80) Note) 10 (0.4) 10 (0.4) 5 (0.2) 10 (0.4) Note) 15 (0.6) Note) 20 (0.80) Note) 5 (0.2) 5 (0.2) 1 pc.
Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 80mm, Thread: TN (NPT), Stroke: 400mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock)
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
No D-M9PV-588 Grommet (Perpendicular) IC circuit 3-wire (PNP) Yes 5 V, 12 V 24 V D-M9P-588 Grommet (in-line) Lead wire length symbols: 0.5 m Nil (Example) D-A93-588 3 m L (Example) D-A93L-588 5 m Z (Example) D-A93Z-588 Note) When mounting an auto switch on a 55-series (Category 2) model, the ATEX class of the cylinder with auto switch changes to Category 3, which is the same class