-XC65 XC6 + XC7 specifications -X1184 Cylinder with reed, heat-resistant switch Mounting Bracket Part No. Refer to pages 322 and 327 for cylinders with auto switches.
CA2 Option Pivot bracket V V V CS1 Symbol Specifications -XC6 Made of stainless steel*1 * A double knuckle joint pin and retaining rings are shipped together.
are the same as the standard double acting, single rod type. 40, 50, 63, 80, 100 Bore size (mm) Air cushion Cushion DAuto switch mounting Tie-rod mounting -X Piston rods, rod end nuts made of stainless steel (-XC6) Made to order Individual -X Specifications other than the above are the same as the standard basic type.
Action Double acting, Single rod Bore size (mm) 20, 25, 32, 40, 50, 63, 80, 100 Cushion None Auto switch mounting Rail mounting (D-F7BAL) Piston rod/Rod end nut material: Stainless steel (-XC6) Made to order Specifications other than above are the same as standard, basic style.
Applicable models D-A73, A73H, A73C, C73, C73C, E73A, Z73, R73 D-97, 93A, A93, A93V D-A33, A34, A33A, A34A, A44, A44A D-A53, A54, B53, B54 2) However, when using a 2 color indication auto switch (DA79W, A59W, B59W), be aware that the switch will constantly remain ON if the connections are reversed.
OUT() Brown Contact protection box CD-P11 CD-P12 Reed switch Note 3) OUT ( ) Blue Mass (g) Model D-A90 D-A90V D-A93 D-A93V D-A96 D-A93, A93V 6 6 6 6 8 8 (m) Lead wire length 0.5 LED 30 30 30 30 41 41 3 Brown (Red) OUT (+) Brown Contact protection box CD-P11 CD-P12 Resistor Dimensions Reed switch (mm) Zener diode D-A90/D-A93/D-A96 OUT () Blue Blue (Black) 2 2.8 4.5 2.7 4 22 (24.5) D-A96,
stroke 12 16 20 25 Series CQS 5, 10, 15, 20 25, 30 5, 10, 15, 20 25, 30, 35, 40 45, 50 Long stroke 12 16 20 Single rod Double rod Return/Extend Single rod Single rod (1) (2) 7-4-4 Double acting Single acting Double acting Double acting 35, 40, 45, 50, 75 100 75, 100, 125, 150 175, 200 75, 100, 125, 150 175, 200, 250, 300 25 Standard Non-rotating Rod Anti-lateral Load Reed switch D-A90/A90V D-A93
Double Rod M O U N T I N G N O O F S W I T C H E S B Basic C Single Clevis L Foot F Front Flange G Rear Flange U Front Trunnion T Rear Trunnion D Double Clevis N Front Nose Mount CONSTRUCTION SPECIFICATIONS 2 Pieces S 1 Piece n n number of switches Rod cover Aluminum alloy (Black Anodizing) O P T I O N S Body Aluminum alloy (Hard Alumite) XC6 Stainless Steel Rod XB6 High Temperature XB7 .
Double Rod M O U N T I N G N O O F S W I T C H E S B Basic C Single Clevis L Foot F Front Flange G Rear Flange U Front Trunnion T Rear Trunnion D Double Clevis N Front Nose Mount CONSTRUCTION SPECIFICATIONS 2 Pieces S 1 Piece n n number of switches Rod cover Aluminum alloy (Black Anodizing) O P T I O N S Body Aluminum alloy (Hard Alumite) XC6 Stainless Steel Rod XB6 High Temperature XB7 .
Mounting Basic Axial foot Rod flange Center trunnion Standard Rod end nut For parts made of stainless steel (-XC6), use the same specification stainless steel with the surface treatment (with hard chrome plated piston rod) (-XC68).
Action Double acting, Single rod Bore size (mm) 20, 25, 32, 40, 50, 63, 80, 100 Cushion None Auto switch mounting Rail mounting (D-F7BAL) Piston rod/Rod end nut material: Stainless steel (-XC6) Made to order Specifications other than above are the same as standard, basic style.
D-M9/M9W/M9A D-A90/A93 Less than 20 stroke Note 2) Less than 55 stroke Note 2) Less than 50 stroke Note 2) Note 2) Minimum stroke for auto switch mounting in styles other than those in Note 1.
How to Order How to Order R R Stroke H7BAL -XC6 CDM2 Mounting Bore size Stroke G5BAL -XC6 CDG1 Mounting Type Bore size With auto switch (built-in magnet) Made to order specification With auto switch (built-in magnet) Made to order specification Water resistant 2 color indication solid state switch Water resistant 2 color indication solid state switch Water resistant cylinder Water resistant
.) : Not available Double acting Action/ Type Single rod Lube Non-lube Air-hydro Applicable bore size Symbol Specification 125 to 300 125 to 160 Standard CDS1 CS120XA XB5 XB6 XB7 XB9 XB16 XC3 XC4 XC5 XC6 Standard 125 to 300 Built-in magnet 125 to 200 J K With rod boot 125 to 300 Copper and Fluorine-free 125 to 160 Change of rod end shape 125 to 300 Oversized rod cylinder 125 to 200 Heat-resistant
LED color indicator Fine adjustment of auto switch Switch bracket Screw attached to auto switch Made to Order Change of rod end shape: -XA0 to 30 Heat resistant cylinder (10 to 150C): -XB6 Made of stainless steel: -XC6 etc. are added.
44.5 A 19.5 29.5 35.5 43 44 53 D 7.5 5 2 5 7 7.5 MY 6 10 15 20 25 32 CY MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.
Same surface Same surface D-A9 D-M9 D-M9W 10 note) 45 45 + 45 (n-2) D-C7 D-C80 10 50 50 + 45 (n-2) D-H7 D-H7W D-H7BAL/H7NF 60 + 45 (n-2) 10 60 D-C73C D-C80C D-H7C 65 + 50 (n-2) 10 65 D-B5/B64 D-G5/K59 D-B59W 75 + 55 (n-2) 10 75 D-B7/B80 D-G79/K79 50 + 45 (n-2) 10 45 Note) For cylinders with 2 auto switches D-A93/M9/M9W.
D-M9/M/9W/M9A Less than 20 stroke Note 2) Less than 55 stroke Note 2) D-A90/A93 Less than 50 stroke Note 2) Note 2) Minimum stroke for auto switch mounting in types other than those mentioned in Note 1. 152 Auto Switch Mounting CJ2Y Series Operating Range Auto Switch Mounting Brackets/Part No.
(Made of stainless steel) XC8 (Adjustable stroke cylinder/Adjustable extension type) 12 MGP12-Z-PS MGP12-Z-XC8-PS 16 MGP16-Z-PS MGP16-Z-XC8-PS 20 MGP20-Z-PS MGP20-Z-PS MGP20-Z-XC8-PS 25 MGP25-Z-PS MGP25-Z-PS MGP25-Z-XC8-PS 32 MGP32-Z-PS MGP32-Z-PS MGP32-Z-XC8-PS 40 MGP40-Z-PS MGP40-Z-PS MGP40-Z-XC8-PS 50 MGP50-Z-XC4-PS MGP50-Z-XC6-PS MGP50-Z-XC8-PS 63 MGP63-Z-XC4-PS MGP63-Z-XC6-PS MGP63
NPN) Piping IC 5V A76H A96V A96 200V A72H A72 Screw-in piping With One-touch fitting (2) F Yes Yes No No Yes Yes Grommet A73H A73 Reed switch 12V 100V A93V A93 Note 2) The tubes for the built-in One-touch fittings are 32 to 63. They cannot be used for the air-hydro.