SMC Corporation of America
Elite Part Number Search
Search Results "CDNA2F50-900-D-A93"

Order Made Auto Switches Lead wire containment groove 81 Series REA/REB Auto Switch Specifications Auto switch application table Auto switch model Cylinder model REBH REAH REAL REAS REBR REAR D-A72, D-A73, D-A80 Reed switches Solid state switches D-A72H, D-A73H, D-A76H, D-A80H D-A73C, D-A80C Note 1) Note 1) D-A90, D-A93, D-A96 Note 2) Note 2) D-Z73, D-Z76, D-Z80 D-F79, D-F7P, D-J79

Auto Switch Proper Mounting Height (Standard type) [mm] Auto switch model D-F5l D-J59 D-F59F D-F5lW D-J59W D-F5BA D-F5NT D-Y59l D-Y7P D-Y7lW D-Y7BA D-Z7l D-Z80 D-M9l D-M9lW D-M9lA D-A9l D-A9lV D-M9lV D-M9lWV D-M9lAV D-A5l D-A6l D-A59W D-Y69l D-Y7PV D-Y7lWV D-P3DWA D-P4DW D-G39 D-K39 D-A3l D-A44 Bore size Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht 32 24.5 23 27.5 23

Stopper (mm) Adjustment bolt Model Stroke adjustment range L L CY1H10, CY1H15, 0 to 15 CY1H20 CY1H25, CY1HT25, 0 to 30 CY1HT32 57 58 Series CY1 Auto Switch Specifications Auto switch application table Auto switch part number Cylinder model CY1R CDY1S CY1L CY1H D-A72, D-A73, D-A80 Reed switches Solid state switches D-A72H, D-A73H, D-A76H, D-A80H D-A73C, D-A80C Note 1) D-A90, D-A93, D-A96

8 6 D-M9/D-F9W 5 4 D-Z7/Z80 9 9 11 A B D-Y59/Y7P D-Y7W 6 6 6 Switches cannot be mounted in some cases.

case of 15. 25, 32 A dimension D-Y5 D-Y6 D-Y7 B dimension C dimension D dimension Auto switch model D-Y5 D-Y6 D-Y7 D-Y5 D-Y6 D-Y7 D-Y5 D-Y6 D-Y7 D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8 Bore size (mm) 25 22 103 103 47 47 78 78 22 32 30.5 117.5 117.5 55.5 55.5 92.5 92.5 30.5 Operating Range Bore size (mm) Auto switch model 32 25 15 D-A9 8 D-M9 3 D-Z7/Z8 9 9 D-Y5/Y6/Y7 6 7 Since this

15 Auto switch model Bore size (mm) D-A9 A dimension D-M9 B dimension C dimension D dimension D-A9 D-M9 D-A9 D-M9 D-A9 D-M9 21.5 76.5 72.5 56.5 60.5 17.5 15 Note) Auto switches cannot be installed in Area C in the case of 15. 25, 32 A dimension D-Y5 D-Y6 D-Y7 B dimension C dimension D dimension Auto switch model D-Y5 D-Y6 D-Y7 D-Y5 D-Y6 D-Y7 D-Y5 D-Y6 D-Y7 D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8

MY1CW16/20 MY1MW16/20 MX B A MTS Reed Switch Solid State Switch D-A90(V), D-A93(V), D-A96(V) (mm) D-M9N(V), D-M9P(V), D-M9B(V) D-F9NW(V), D-F9PW(V), D-F9BW(V) MY 16 20 Mounting position 16 20 Mounting position Mounting position 16 20 93 94 A A A 73 74 70 90 CY 107 106 B B B 87 86 90 110 6.5 7 8.5 6.5 Operating range Note) Operating range Note) Operating range Note) 11 7.5 MG CX MY1MW25/32

If this is not done, the tie-rods or piston rod assembly will be damaged. 75 Series C96 How to Mount and Move the Auto Switch 1 Tie-rod Mounting Type Mounting Bracket Solid state switch D-M9N(V), D-M9P(V), D-M9B(V) D-M9NW(V), D-M9PW(V), D-M9BW(V) D-M9NA(V), D-M9PA(V), D-M9BA(V) Reed switch D-A90(V), A93(V), A96(V) Solid state switch D-G39

MY1CW16/20 MY1MW16/20 B A Reed Switch Solid State Switch D-A90(V), D-A93(V), D-A96(V) (mm) D-M9N(V), D-M9P(V), D-M9B(V) D-F9NW(V), D-F9PW(V), D-F9BW(V) 16 20 Mounting position Mounting position 16 20 A A B B Operating range Note) Operating range Note) Solid State Switch Reed Switch 24 Series MY1W Mounting of Auto Switch & Installation of Lead Wire Cover (50, 63) Caution Be sure to install

Auto Switch Internal Circuit D-A90 (V) Contact protection box OUT () Brown Reed switch Unit: g Weight Table CD-P11 OUT () Blue CD-P12 D-A90 D-A90V D-A93 D-A93V D-A96 D-A96V Model Lead wire length: 0.5 m 6 6 6 6 8 8 D-A93 (V) Lead wire length: 3 m 30 30 30 30 41 41 LED diode Brown OUT (+) Brown Contact protection box Resistor Unit: mm Dimensions Reed switch Zener diode CD-P11 D-A90/D-A93/D-A96

model D-F5 D-J5 D-F5W D-J59W D-F5BAL D-F59F D-F5NTL D-A5 D-A6 D-A3 D-A44 D-G39 D-K39 D-F5W D-J59W D-F5BAL D-F5 D-J5 D-F59F D-A59W D-F5NTL Bore size (mm) Bore size (mm) A B A B A B A B Hs Hs Ht Hs Hs Ht 125 125 2 75.5 69.5 74.5 70 116 126 4.5 4.5 9.5 9.5 0 0 2 140 140 2 81 76.5 80 76.5 124 134 4.5 4.5 9.5 9.5 0 0 2 160 160 2 89 87.5 88 87.5 134.5 144.5 4.5 4.5 9.5 9.5 0 0 2 180 180 7.5 97.0

However, if there is any problem, use a 3 wire DC style. 3.8-11 Series CXT Auto Switch Mounting Position and Mounting Height Reed switch Solid state switch A B W D-F9NW D-F9PW D-F9BW D-A90 D-A93 D-A96 D-F9N D-F9P D-F9B D-F9BAL 12 A B W 16, 20, 25 W A B 32, 40 (mm) D-A90 D-A93 D-A96 D-F9NW D-F9PW D-F9BW D-F9N D-F9P D-F9B Auto switch model D-F9BAL Symbol A B W A B W A B W Standard stroke 12

8 6 D-F9, D-F9W 5 4 D-Z7, Z80 9 9 11 A B D-Y59, Y7P D-Y7W 6 6 6 Switches cannot be mounted in some cases.

) (1000) (900) (1000) (1000) Caution MY1CW20 MY1CW20 MY1CW16 MY1MW16 MY1MW16 MY1CW16 (900) (900) (900) (900) (900) (900) 20 20 1.

Auto Switch Proper Mounting Position for Stroke End Detection MY1CW 16, 20 MY1MW 16, 20 B A Reed switch D-A90(V), D-A93(V), D-A96(V) Solid state switch D-F9N(V), D-F9P(V), D-F9B(V) D-F9NW(V), D-F9PW(V), D-F9BW(V) Mounting position 20 16 20 16 20 Mounting position Mounting position 16 A 90 70 93 73 94 A A 74 B 110 90 107 87 106 B B 86 Operating range Note) 7.5 11 6.5 8.5 6.5 Operating range

8 6 D-F9, D-F9W 5 4 D-Z7, Z80 9 9 11 A B D-Y59, Y7P D-Y7W 6 6 6 Switches cannot be mounted in some cases.

10 2 10 15 20 CXT 32 40 5 15 10 5 1 10 10 20 (mm) D-F7W D-J79W D-F7BAL D-F7NT D-F79F Auto switch model D-A7 D-A8 D-A73C D-A80C D-A7H D-A80H D-F7 D-J79 D-F7V D-J79C D-F7WV D-F7BAVL D-A79W Application No. of auto switches mounted 2 5 10 15 15 20 20 CXT 32 40 1 5 5 10 15 15 20 Other than the applicable auto switches listed in How to Order, the following auto switches can be mounted.

Proper Auto Switch Mounting Position (Detection at stroke end) C D Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A B Series MY2C Series MY2H Series MY2HT (mm) D-M9, D-M9V (mm) D-M9, D-M9V (mm) D-M9, D-M9V A A A B B B Bore size 16 25 40 Operating range Bore size

Note 5) Dimensions other than those marked (LA) are the same as the basic type (no locking type). 598 RS2H Series Auto Switch Mounting 1 Auto Switch Proper Mounting Position (Detection at Stroke End) D-M9 D-M9W D-M9AV D-M9V D-M9WV D-M9A D-A9 D-A9V A B Auto switch Auto Switch Proper Mounting Position (mm) Auto switch model D-M9 D-M9W D-M9AV D-M9V D-M9WV D-M9A D-A9 D-A9V A 9.0 B 23.5 A 11.0