Cylinder: DP (Auto Switch/Plate Mount), Bearing Style: M (Slide Bearing), Bore Size: 25mm, Stroke: 75mm, End Lock: None, Auto Switch: J79W--Solid State, 2-color Indication, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)

Cylinder: DP (Auto Switch/Plate Mount), Bearing Style: M (Slide Bearing), Bore Size: 25mm, Stroke: 25mm, End Lock: None, Auto Switch: J79W--Solid State, 2-color Indication, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)

Cylinder: DP (Auto Switch/Plate Mount), Bearing Style: M (Slide Bearing), Bore Size: 25mm, Stroke: 125mm, End Lock: None, Auto Switch: J79W--Solid State, 2-color Indication, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Stroke with Adjustment, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: No, Valves: -, Cushion: Shock absorber,

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Stroke with Adjustment, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: No, Valves: -, Cushion: Shock absorber

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Stroke with Adjustment, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: No, Valves: -, Cushion: Shock absorber,

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Stroke with Adjustment, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: No, Valves: -, Cushion: Shock absorber

Magnet: D (Built-in), Bore Size: 25 (1 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 0600 (6 Inch), Adjuster: Adjuster Bolt, Auto Switch: J79WL--Solid State, 2-color Indication, 2 Wire, Horizontal, 3M

Magnet: D (Built-in), Bore Size: 40 (1 1/2 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 1200 (12 Inch), Adjuster: Adjuster Bolt, Auto Switch: J79WL--Solid State, 2-color Indication, 2 Wire, Horizontal, 3M

Lead wire length symbols: 0.5 m Nil 3 m L 5 m Z None N (Example) J79W (Example) J79WL (Example) J79WZ (Example) J79CN Since there are other applicable auto switches than listed, refer to page 1520 for details. For details about auto switches with pre-wired connector, refer to pages 1648 and 1649.

Magnet: D (Built-in), Bore Size: 25 (1 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 1000 (10 Inch), Adjuster: Adjuster Bolt, Auto Switch: J79WL--Solid State, 2-color Indication, 2 Wire, Horizontal, 3M

Magnet: D (Built-in), Bore Size: 25 (1 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 1000 (10 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: J79WL--Solid State, 2-color Indication, 2 Wire, Horizontal, 3M

Magnet: D (Built-in), Bore Size: 25 (1 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 0200 (2 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: J79WL--Solid State, 2-color Indication, 2 Wire, Horizontal, 3M

Magnet: D (Built-in), Bore Size: 32 (1 1/4 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 0800 (8 Inch), Adjuster: Adjuster Bolt, Auto Switch: J79WL--Solid State, 2-color Indication, 2 Wire, Horizontal, 3M

Magnet: D (Built-in), Bore Size: 32 (1 1/4 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 1000 (10 Inch), Adjuster: BC (Cap Type Shock Absorber (2 pcs.)), Auto Switch: J79WL--Solid State, 2-color Indication, 2 Wire, Horizontal, 3M

Magnet: D (Built-in), Bore Size: 25 (1 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 0500 (5 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: J79WL--Solid State, 2-color Indication, 2 Wire, Horizontal, 3M, Number: S (1 pc.)

Magnet: D (Built-in), Bore Size: 15 (5/8 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 1000 (10 Inch), Adjuster: Adjuster Bolt, Auto Switch: J79WL--Solid State, 2-color Indication, 2 Wire, Horizontal, 3M

Magnet: D (Built-in), Bore Size: 15 (5/8 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 1000 (10 Inch), Adjuster: BC (Cap Type Shock Absorber (2 pcs.)), Auto Switch: J79WL--Solid State, 2-color Indication, 2 Wire, Horizontal, 3M

Magnet: D (Built-in), Bore Size: 15 (5/8 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 2500 (25 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: J79WL--Solid State, 2-color Indication, 2 Wire, Horizontal, 3M

Magnet: D (Built-in), Bore Size: 25 (1 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 0500 (5 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: J79WL--Solid State, 2-color Indication, 2 Wire, Horizontal, 3M, Number: 3 pcs.