Measurement circuit of cylinder output relative to supply pressure CQ2B40-75D (Standard) CQ2XB40-75D (Low speed cylinder) RE A B [Example of test method] The test sample is in place in an acrylic chamber. The chamber is set up on a Class 100 clean bench. The solenoid valve is operated while supplying a volume of clean air equal to the intake volume of a laser dust monitor (28.3 l/min).
Supply pressure cylinder output characteristic measuring circuit CQ2B40-75D (standard) CQ2XB40-75D (microspeed cylinder) Front supply pressure: 0.025MPa Front supply pressure: 0.025MPa 686 686 Test cylinder Load converter 588 588 Theoretical thrust Theoretical thrust 490 490 Analyzing recorder Actual thrust Actual thrust 392 392 Thrust N Thrust N Pressure converter 294 294 196 196 Pressure
Lead wire length symbols: 0.5 mNil (Example) M9N 3 mL (Example) M9NL 5 mZ (Example) M9NZ Normally closed (NC=b contact), solid state switches (Model D-F9G, F9H) are also available. For detail, refer to page 7-9-23 in the Best Pneumatics 2004 Vol. 7 catalog.
Measurement circuit of cylinder output relative to supply pressure CQ2B40-75D (standard) CQ2XB40-75D (microspeed cylinder) Front supply pressure: 0.025MPa Front supply pressure: 0.025MPa 686 686 Test cylinder Load converter 588 588 Theoretical thrust Theoretical thrust 490 490 Analyzing recorder Actual thrust Actual thrust 392 392 Thrust N Thrust N Pressure converter 294 294 196 196 Pressure
0 Description Main parts Replacement Parts MHT2-32D MHT2-40D MHT2-50D MHT2-63D Finger assembly MH-TA3201 MH-TA4001 MH-TA5001 MH-TA6301 wo Lever assembly MH-TA3202 MH-TA4002 MH-TA5002 MH-TA6302 e <32, 40> weryio Link parts assembly MH-TA3203 MH-TA4003 MH-TA5003 MH-TA6303 <50, 63> werio CDQ2A32-15D CDQ2A40-15D CDQ2A50-20D CDQ2A63-20D Compact cylinder !
0 Description Main parts Replacement Parts MHT2-32D MHT2-40D MHT2-50D MHT2-63D Finger assembly MH-TA3201 MH-TA4001 MH-TA5001 MH-TA6301 wo Lever assembly MH-TA3202 MH-TA4002 MH-TA5002 MH-TA6302 e <32, 40> weryio Link parts assembly MH-TA3203 MH-TA4003 MH-TA5003 MH-TA6303 <50, 63> werio CDQ2A32-15D CDQ2A40-15D CDQ2A50-20D CDQ2A63-20D Compact cylinder !
Z M9NZ 1 Series NCQ8 Specifications 106 (1-1/16") 200 (2") 250 (2-1/2") 056 (9/16") #10-32UNF 075 (3/4") 150(1-1/2") Bore size #10-32UNF NPT1/8 NPT1/8 NPT1/8 NPT1/4 Piping size Pneumatic (Non-lube) Type Double acting, Single rod Action Air Fluid 300PSI (2.1MPa) Proof pressure 200PSI (1.4MPa) Maximum operating pressure 056 11PSI (0.07MPa) Minimum operating pressure 075 to 250 8PSI (0.05MPa
Lead wire length symbols: 0.5 mNil (Example) M9N 3 m L (Example) M9NL 5 m Z (Example) M9NZ Solid state switches marked "" are produced upon receipt of order.
M9P M9B F9NW F9PW F9BW A93V A90V M9NV M9PV M9BV F9NWV F9PWV F9BWV 2-wire Relay, PLC IC circuit 100 V or less No 3-wire (NPN) IC circuit 5 V, 12 V 3-wire (PNP) 2-wire 12 V Grommet Relay, PLC Yes 24V 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 2-wire 12 V Lead wire length symbols: 0.5 mNil (Example) M9N 3 mL (Example) M9NL 5 mZ (Example) M9NZ
Yes Grommet Relay, PLC A93 A93V 2-wire 12 V 24 V 100 V M9N M9NV 3-wire (NPN) IC circuit 5 V, 12 V M9P M9PV 3-wire (PNP) Relay, PLC M9B M9BV 2-wire 12 V 24 V Grommet F9NW F9NWV 3-wire (NPN) 5 V, 12 V Diagnostic indication (2-color indication) F9PW F9PWV 3-wire (PNP) F9BW F9BWV 2-wire 12 V Lead wire length symbols: 0.5 mNil (Example) M9N 3 m L (Example) M9NL 5 m Z (Example) M9NZ
In-line 0.5 (Nil) 3 (L) 5 (Z) DC AC Electrical entry Indicator light Wiring (Output) Perpendicular Special function Type M9NV F8N M9PV F8P M9BV F8B M9N M9P M9B Standard Standard Standard 3-wire (NPN) 3-wire (PNP) 24 V Solid state switch 5 V 12 V IC circuit Relay, PLC Grommet Yes 2-wire 12 V Lead wire length symbols: 0.5 m Nil (Example) M9BV 3 m L (Example) M9NL 5 m Z (Example) M9NZ
Lead wire length symbols:0.5 m Nil (Example) M9N 3 m L (Example) M9NL 5 m Z (Example) M9NZ Refer to page 12-13-25 for solid state switch with pre-wire connector. 12-5-4 5 2 Finger Rotary Actuated Air Gripper Series MHR2/MDHR2 30 Model/Specifications Nominal size 10 15 20 Action Double acting Gripping force (N) (1) External grip 12 24 33 58 (Effective value) at 0.5 MPa Internal grip 12 34
In-line 0.5 (Nil) 3 (L) 5 (Z) DC AC Electrical entry Indicator light Wiring (Output) Perpendicular Special function Type M9NV F8N M9PV F8P M9BV F8B M9N M9P M9B Standard Standard Standard 3-wire (NPN) 3-wire (PNP) 24 V Solid state switch 5 V 12 V IC circuit Relay, PLC Grommet Yes 2-wire 12 V Lead wire length symbols: 0.5 m Nil (Example) M9BV 3 m L (Example) M9NL 5 m Z (Example) M9NZ
Standard strokes (mm) Bore sizes (mm) 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 32, 40 50, 63 80, 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Example) For CQ2XB40-57D, an 18mm spacer is installed inside a standard stroke CQ2XB40-75D cylinder. Specific Product Precautions Be sure to read before handling. Refer to pages 15 to 24 for safety instructions and precautions.
Example) For 10-CQ2XB40-57D, an 18mm spacer is installed inside a standard stroke 10-CQ2XB40-75D cylinder. Manufacturing intermediate strokes Intermediate strokes can be manufactured in 1mm increments by installing spacers in a standard stroke cylinder. The total length of the cylinder is the same as the longer standard stroke.
Lead wire length symbols: 0.5 mNil (Example) M9N 3 m L (Example) M9NL 5 m Z (Example) M9NZ Refer to page 10-12-16 for details on other applicable auto switches than listed above.
Applicable model Load voltage Type Special function Electrical entry Wiring (Output) 0.5 Nil 3 (L) 5 Note 2) DC Perpendicular 10 16 20 25 In-line AC (Z) M9NV F8N M9PV F8P M9BV F8B M9N M9P M9B 3-wire (NPN) Solid state auto switch 5 V 12 V IC circuit Relay PLC 3-wire (PNP) 24 V Grommet 2-wire 12 V Note 1) Lead wire length symbols: 0.5 mNil (Example) M9N 3 mL (Example) M9NL 5 mZ (Example) M9NZ
Z (Example) M9NZ PLC: Programmable Logic Controller Refer to page 889 for the applicable auto switch list. 799 MXQ 1322Air Slide Table Specifications 6 8 12 16 20 25 Bore size (mm) Fluid Air Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches/ Pressure Sensors Directional Control Valves Air Grippers Modular F. R.
Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L 5 m Z (Example) M9NZ Refer to page 8-28-27 for additional details and applicable auto switches other than the above types.
Lead wire length symbols: 0.5 mNil (Example) M9N 3 m L (Example) M9NL 5 m Z (Example) M9NZ Refer to page 10-12-16 for details on other applicable auto switches than listed above.