Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket
Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 100mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 20mm, Body Option: CM (C+M), Auto Switch Groove: Z (Auto Switch Mounting Grooves)
Magnet: Built-in, Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 100mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 20mm, Body Option: C+M, Auto Switch Groove: Auto Switch Mounting Grooves, Mounting Bolt: None, Rod End Bracket: None, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: -, Number:
Magnet: Built-in, Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 100mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 20mm, Body Option: C+M, Auto Switch Groove: Auto Switch Mounting Grooves, Mounting Bolt: None, Rod End Bracket: None, Auto Switch: M9BV--Solid State , Gen. Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: 5m, Number: -, Mounting
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket
Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 100mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 20mm, Body Option: CM (C+M), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: M9BV--Solid State , Gen. Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: Z (5m
Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 100mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 20mm, Body Option: CM (C+M), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 100mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 20mm, Body Option: CM (C+M), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal
Band Mount: None, Rail Mount: None, Tie-rod Mount: None, Direct Mount: M9BWV--Solid State, 2-color Indication, 2 Wire, Vertical, Lead Wire or Prewired Connector: SBPC (0.5m Cord Length, M8-4 Pin Connector)
Sensor Type: Non-Contact, Output Format: NPN Format, Wiring Method: 3-Wire, Type: Main Body, Wiring type: 2-wire, Output Type: None, Electrical entry direction: Perpendicular, Lead wire length(m): 0.5, Connector Type: M8 4-pin
Bearing Type: L (Ball bushing bearing), Bore Size: 25mm, Port Type: Bore 12-16: M5x0.8; Bore 20-100: Rc, Stroke: 175mm, Auto Switch: M9BWV--Solid State, 2-color Indication, 2 Wire, Vertical, Lead Wire or Prewired Connector: SBPC (0.5m Cord Length, M8-4 Pin Connector)
Mounting: B (Through-hole/Both Ends Tapped Common, Basic), Bore Size: Ø20 mm, Port Thread: M thread: ø12 to ø25, Rc: 32 to 63, Clamp Stroke: 20 mm, Rotary Direction: R (Clockwise), Body Option: Standard (Female Thread), Auto Switch: M9BWV--Solid State, 2-color Indication, 2 Wire, Vertical, Lead Wire or Prewired Connector: SBPC (0.5m Cord Length, M8-4 Pin Connector)
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 100mm, Port Thread Type: Rc, Stroke: 125mm, Body Option: M (Rod End Male Thread), Auto Switch: M9BWV--Solid State, 2-color Indication, 2 Wire, Vertical, Lead Wire or Prewired Connector: SBPC (0.5m Cord Length, M8-4 Pin Connector)
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Type: Standard, Bore Size: 20mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 15mm, Body Option: Standard (Rod End Female Thread, Without thread on 4mm bore), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: M9BWV--Solid State, 2-color Indication, 2 Wire
Magnet: D (Built-in), Mounting: D (Double Clevis), Type: Standard, Bore Size: 25mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 15mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: M9BWV--Solid State, 2-color Indication, 2 Wire, Vertical, Lead Wire or Prewired Connector
Magnet: -, Mounting: -, Type: -, Bore Size: -, Port Thread: -, Stroke 1: -, +: -, Stroke 2: -, Body Option: -, Auto Switch Groove: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Stroke Options: -
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 175, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: Rc, Auto
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket: