Lead wire length (m) Indicator light Load voltage Applicable load Rail mounting Direct mounting Pre-wire connector Wiring (Output) Special function Type Electrical entry 32 to 100 12 to 100 0.5 (Nil) 3 (L) 5 (Z) None (N) AC DC In-line In-line Perpendicular Perpendicular 3-wire (NPN equivalent) IC circuit 5V A76H A96 A96V Grommet A72H A73H 200 V A72 A73 A73C A93 A93V Reed switch Solid
Lead wire length (m) Indicator light Direct mounting Load voltage Applicable load Rail mounting Pre-wire connector Wiring (Output) Special function Type Electrical entry 32 to 100 12 to 100 0.5 (Nil) 3 (L) 5 (Z) None (N) AC DC In-line In-line Perpendicular Perpendicular 3-wire (NPN equivalent) IC circuit 5V A96V A76H A96 Grommet A72H A73H 200 V A72 A73 A73C A93V A93 Reed switch Solid
NPN) Piping IC 5V A76H A96V A96 200V A72H A72 Screw-in piping With One-touch fitting (2) F Yes Yes No No Yes Yes Grommet A73H A73 Reed switch 12V 100V A93V A93 Note 2) The tubes for the built-in One-touch fittings are 32 to 63. They cannot be used for the air-hydro.
Long stroke CXT12 CXT16 CXT20 CXT25 CXT32 CXT40 CQSB12-L-PS CQSB16-L-PS CQSB20-L-PS CQSB25-L-PS CQ2A32-L-PS CQ2A40-L-PS CDQSB12 CDQSB16 CDQSB20 CDQSB25 CDQ2A32 CDQ2A40 Seal kit includes @7, @8 and @9. Order the seal kit with the kit number. Since the seal kit does not include a grease pack, order it separately.
Auto Switch Proper Mounting Position (Detection at Stroke End) D-A93 12 16 to 25 A B W A B W D-M9B/M9N 12 16 to 25 A B W A B W B D-A93 B D-M9B/M9N/M9P Bore size (mm) A 11.5 W 4 A 15.5 W 5.5 12 16 20 25 0.5 4.5 12 0 4.5 16 4 6 16 3.5 1 20 7.5 2.5 17 5.5 -1 21 9.5 0.5 Specific Product Precautions Be sure to read this before handling. Mounting Caution 1.
44.5 A 19.5 29.5 35.5 43 44 53 D 7.5 5 2 5 7 7.5 MY 6 10 15 20 25 32 CY MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.
However, if there is any problem, use a 3 wire DC style. 3.8-11 Series CXT Auto Switch Mounting Position and Mounting Height Reed switch Solid state switch A B W D-F9NW D-F9PW D-F9BW D-A90 D-A93 D-A96 D-F9N D-F9P D-F9B D-F9BAL 12 A B W 16, 20, 25 W A B 32, 40 (mm) D-A90 D-A93 D-A96 D-F9NW D-F9PW D-F9BW D-F9N D-F9P D-F9B Auto switch model D-F9BAL Symbol A B W A B W A B W Standard stroke 12
Replacement Parts/Seal Kit Cylinder Model CXT12 CXT16 CXT20 CXT25 CXT32 CXT40 DCDQSB12 CDQSB16 CDQSB20 CDQSB25 CDQ2A32 CDQ2A40 Stroke Standard stroke CQSB12-PS CQSB16-PS CQSB20-PS CQSB25-PS CQ2B32-PS CQ2B40-PS -X Long stroke CQSB12-L-PS CQSB16-L-PS CQSB20-L-PS CQSB25-L-PS CQ2A32-L-PS CQ2A40-L-PS Seal kit includes @7, @8 and @9. Order the seal kit with the kit number.
Lead wire length (m) Load voltage Rail mounting Direct mounting Indicator light Special function Type Electrical entry Wiring (Output) Pre-wire connector Applicable load 12 to 40 32, 40 0.5 (Nil) 3 (L) 5 (Z) None (N) AC DC In-line In-line Perpendicular Perpendicular 3-wire (NPN equivalent) IC circuit 5 V A76H A96V A96 A93V A93 A72H A73H A72 A73 A73C 200 V Grommet Reed switch Solid
CQSB25-PS CQ2B32-PS CQ2B40-PS Long stroke CQSB12-L-PS CXT12 CXT16 CXT20 CXT25 CXT32 CXT40 CQSB12-L-PS CQSB16-L-PS CQSB20-L-PS CQSB25-L-PS CQ2A32-L-PS CQ2A40-L-PS CDQSB12 CDQSB16 CDQSB20 CDQSB25 CDQ2A32 CDQ2A40 CQSB16-L-PS CQSB20-L-PS CQSB25-L-PS CQ2A32-L-PS CQ2A40-L-PS Seal kit includes @7, @8 and @9. Order the seal kit with the kit number.
CQSB25-PS CQ2B32-PS CQ2B40-PS Long stroke CQSB12-L-PS CXT12 CXT16 CXT20 CXT25 CXT32 CXT40 CQSB12-L-PS CQSB16-L-PS CQSB20-L-PS CQSB25-L-PS CQ2A32-L-PS CQ2A40-L-PS CDQSB12 CDQSB16 CDQSB20 CDQSB25 CDQ2A32 CDQ2A40 CQSB16-L-PS CQSB20-L-PS CQSB25-L-PS CQ2A32-L-PS CQ2A40-L-PS Seal kit includes @7, @8 and @9. Order the seal kit with the kit number.
Magnet: D (Built-in), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 20mm, Stroke: 20mm, Option: M (Rod End Male Thread)
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches
Magnet: D (Built-in Magnet), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 20mm, Stroke: 20mm, Option: M (Rod End Male Thread)
Clean Series: 11 (Vacuum Suction Type), Magnet: D (Built-in), Bore Size: 20mm, Stroke: 20mm, Rod End Thread: M (Male)
Clean Series: 10 (Relief Type), Magnet: D (Built-in), Bore Size: 20mm, Stroke: 20mm, Rod End Thread: M (Male)
Clean Series: 22 [Vacuum Suction Type (Copper, Fluorine and Silicon-free + Low Particle Generation)], Magnet: D (Built-in), Bore Size: 20mm, Stroke: 20mm, Rod End Thread: M (Male)
Magnet: D (Built-in), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 20mm, Stroke: 20mm, Option: M (Rod End Male Thread), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 0.5m, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 20mm, Stroke: 20mm, Option: M (Rod End Male Thread), Auto Switch: A90V--Reed, DC Volt, AC Volt, Vertical, 0.5m