SMC Corporation of America
Elite Part Number Search
Search Results "CLSD200TN-200"

Magnet: None, Mounting: D (Double Clevis), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 200mm, Thread: TN (NPT), Stroke: 250mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs.

Magnet: None, Mounting: D (Double Clevis), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 200mm, Thread: TN (NPT), Stroke: 700mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs.

Magnet: None, Mounting: D (Double Clevis), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 200mm, Thread: TN (NPT), Stroke: 1200mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs.

Magnet: None, Mounting: D (Double Clevis), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 200mm, Thread: TN (NPT), Stroke: 500mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs.

Cylinder (Tube) Inner Diameter(φ): 200, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 200, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Magnet: None, Mounting: Double Clevis, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 200mm, Thread: NPT, Stroke: 250mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs.

Magnet: None, Mounting: Double Clevis, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 200mm, Thread: NPT, Stroke: 700mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs.

Magnet: None, Mounting: Double Clevis, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 200mm, Thread: NPT, Stroke: 1200mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs.

The CLS series cylinder with lock is ideal for applications requiring intermediate and emergency stop and drop prevention. The compact lock unit is lightweight and saves space. A switch is optional on the brake cylinder so the operating state of the lock unit (brake piston) can be detected using the switch signal. By separating the lock mechanism and the brake cylinder, SMC has minimized

The CLS series cylinder with lock is ideal for applications requiring intermediate and emergency stop and drop prevention. The compact lock unit is lightweight and saves space. A switch is optional on the brake cylinder so the operating state of the lock unit (brake piston) can be detected using the switch signal. By separating the lock mechanism and the brake cylinder, SMC has minimized

The CLS series cylinder with lock is ideal for applications requiring intermediate and emergency stop and drop prevention. The compact lock unit is lightweight and saves space. A switch is optional on the brake cylinder so the operating state of the lock unit (brake piston) can be detected using the switch signal. By separating the lock mechanism and the brake cylinder, SMC has minimized

The CLS series cylinder with lock is ideal for applications requiring intermediate and emergency stop and drop prevention. The compact lock unit is lightweight and saves space. A switch is optional on the brake cylinder so the operating state of the lock unit (brake piston) can be detected using the switch signal. By separating the lock mechanism and the brake cylinder, SMC has minimized

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CLS1 ONE WAY LOCK-UP CYLINDER, XD, 200MM CLS1 DOUBLE ACTING

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER LOCKING, ACTUATOR, CLS1 ONE WAY LOCK-UP CYLINDER, XD, 200MM CLS1 DOUBLE ACTING, 169.75594 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER LOCKING, ACTUATOR, CLS1 ONE WAY LOCK-UP CYLINDER, XD, 200MM CLS1 DOUBLE ACTING, 169.75594 lb

The CLS series cylinder with lock is ideal for applications requiring intermediate and emergency stop and drop prevention. The compact lock unit is lightweight and saves space. A switch is optional on the brake cylinder so the operating state of the lock unit (brake piston) can be detected using the switch signal. By separating the lock mechanism and the brake cylinder, SMC has minimized

Note 3) Refer to page 200 for dimensions of A or B port top-ported type.

T-slot 2 dimensions Compatible Motors Switch Internal Circuit D-Y7GL Motor output (W) Motor model Brake Manufacturer Power supply voltage (VAC) Motor specification symbol Controller driver model + Brown lead wire 100/110 200/220 100 200 100/115 200/230 100/115 200/230 100/115 200/230 100/115 200/230 100/115 200/230 100/115 200/230 LC1-1B1H1Without brake (Horizontal specification) Main circuit

Refer to pages starting with 140 for mounting. 18 T-slot 2 dimensions Compatible Motors Switch Internal Circuit D-Y7GL Motor output (W) Motor model Brake Manufacturer Power supply voltage (VAC) Motor specification symbol Controller driver model + Brown lead wire LC1-1B1H1100/110 200/220 100 200 100/115 200/230 100/115 200/230 100/115 200/230 100/115 200/230 100/115 200/230 100/115 200/230