+ 55 n = 2, 4, 6, 8 25 + 55 n = 2, 4, 6, 8 n (Same side) D-A59W CA2 1 15 25 25 D-F5 D-J5 D-F5W D-J59W D-F5BAL D-F59F 15 25 25 2 (Different sides or Same side) CS1 (n2) 2 (n2) 2 (n2) 2 15 + 55 n = 2, 4, 6, 8 25 + 55 n = 2, 4, 6, 8 25 + 55 n = 2, 4, 6, 8 n (Same side) C76 1 10 25 25 25 30 2 (Different sides or Same side) 15 C85 (n2) 2 (n2) 2 (n2) 2 15 + 55 n = 2, 4, 6, 8 25 + 55 n = 2, 4,
Measurement circuit of cylinder output relative to supply pressure CQ2B40-75D (standard) CQ2XB40-75D (microspeed cylinder) Front supply pressure: 0.025MPa Front supply pressure: 0.025MPa 686 686 Test cylinder Load converter 588 588 Theoretical thrust Theoretical thrust 490 490 Analyzing recorder Actual thrust Actual thrust 392 392 Thrust N Thrust N Pressure converter 294 294 196 196 Pressure
Minimum Auto Switch Mounting Stroke (mm) Auto switch model D-M9W D-M9A Bore size (mm) D-A9 D-A9V D-M9 D-M9V D-M9WV D-M9AV D-P3DW No. of auto switch mounted 2 pcs. 1 pc. 2 pcs. 1 pc. 2 pcs. 1 pc. 2 pcs. 1 pc. 2 pcs. 1 pc. 10 10 10 10 10 10 10 5 10 10 10 5 10 5 10 5 10 5 10 5 15 15 10 10 10 10 10 5 15 15 15 15 15 15 15 15 15 15 15 15 5 5 5 5 5 5 5 5 5 5 10 5 10 5 10 5 10 5 10 5 10 10 10 10
Minimum Stroke for Auto Switch Mounting (mm) D-M9 10 D-M9V 5 D-M9W 15 D-M9WV 10 D-A9 10 D-A9V 5 Bore size (mm) 321, 40 502, 63 No. of auto switch mounted With 1 pc. 10 5 15 15 10 10 With 2 pcs. 1 The outline dimensions for 5 mm stroke will be the same as those for 10 mm stroke. 2 The outline dimensions for 10 mm stroke will be the same as those for 15 mm stroke. 10 Prior to Use Auto Switches
10 2 pcs. 10 10 25 to 5 20 15 5 1 pc. 10 10 25 CXTl25 5 15 10 10 2 pcs. 10 15 20 CXTl 32 40 5 15 10 5 1 pc. 10 10 20 (mm) D-F7lW D-J79W D-F9BAL D-F7NT D-F79F Auto switch model D-A7l D-A8l D-A73C D-A80C D-A7lH D-A80H D-F7l D-J79 D-F7lV D-J79C Applicable model D-F7lWV D-A79W D-F7LF Number of mountings 2 pcs. 5 10 15 15 20 20 25 CXTl 32 40 1 pc. 5 5 10 15 15 20 25 3.8-10 Platform Cylinder Series
10 2 10 15 20 CXT 32 40 5 15 10 5 1 10 10 20 (mm) D-F7W D-J79W D-F7BAL D-F7NT D-F79F Auto switch model D-A7 D-A8 D-A73C D-A80C D-A7H D-A80H D-F7 D-J79 D-F7V D-J79C D-F7WV D-F7BAVL D-A79W Application No. of auto switches mounted 2 5 10 15 15 20 20 CXT 32 40 1 5 5 10 15 15 20 Other than the applicable auto switches listed in How to Order, the following auto switches can be mounted.
15 20 5 CXT 32 40 1 10 10 5 10 15 5 2 10 15 10 10 15 5 (mm) D-F7W D-J79W D-F7BAL D-F7NTL D-F79F Auto switch model D-A7 D-A8 D-A73C D-A80C D-A7H D-A80H D-F7 D-J79 D-F7V D-J79C D-F7WV D-F7BAVL D-A79W Application No. of auto switches mounted CXT 32 40 1 5 5 10 15 15 20 2 5 10 15 15 20 20 Proper Auto Switch Mounting Position (Detection at stroke end) and Its Mounting Height D-A9 D-M9 D-M9W D-M9AL
Minimum Auto Switch Mounting Stroke (mm) Auto switch model Bore size (mm) D-A9 A9V D-M9 D-M9V D-F9W D-F9WV D-F9BAL Number of auto switches 2 pcs. 10 5 15 10 20 10 15 20 1 pc. 5 5 15 5 20 10 15 2 pcs. 10 5 10 10 20 10 10 25,32,40,50 1 pc. 5 5 10 5 20 10 10 2 pcs. 10 5 10 10 15 10 10 63 1 pc. 5 5 10 5 15 5 5 Besides the models listed in How to Order, the following auto switches are applicable
point L (mm) Gripping point L (mm) 15 15 5 5 10 10 20 20 25 25 30 30 MHW F F MRHQ MHS3-20D MHS3-20D 40 Pressure 0.6 MPa Misc. 35 Pressure 0.6 MPa 35 30 External grip 0.5 MPa 0.5 MPa DGripping force (N) Gripping force (N) 30 25 25 20 20 15 15 0.4 MPa 0.4 MPa F 200.3 MPa 0.3 MPa 0.2 MPa 0.2 MPa 10 10 5 5 0 0 5 5 25 25 10 10 15 15 20 20 30 30 35 35 Gripping point L (mm) Gripping point L (mm
External Gripping Force Internal Gripping Force MHS3-16D MHS3-16D 25 25 Pressure 0.6 MPa 20 20 Gripping force (N) Pressure 0.6 MPa Gripping force (N) 0.5 MPa 0.5 MPa 15 15 0.4 MPa 0.4 MPa 10 10 0.3 MPa 0.3 MPa 0.2 MPa 0.2 MPa 5 5 F 0 0 5 5 10 10 20 20 25 25 30 30 15 15 Gripping point L (mm) Gripping point L (mm) F F MHS3-20D MHS3-20D 40 Pressure 0.6 MPa Pressure 0.6 MPa MHZ 35 External grip
5, 10, 15, 20 25, 30 2.2-10 20 25 5, 10, 15, 20 25, 30, 35, 40 45, 50 Series CQS 12, 16 20, 25 12 16 20 25 5, 10 2.2-16 Solid state switch D-F9N, F9NV D-F9P, F9PV D-F9B, F9BV D-F9NW, F9NWV D-F9PW, F9PWV D-F9BW, F9BWV Series CQSK 12 16 5, 10, 15, 20 25, 30 20 25 5, 10, 15, 20 25, 30, 35, 40 45, 50 2.2-24 Series CQSlS 12 16 5, 10, 15, 20 25, 30 20 25 5, 10, 15, 20 25, 30, 35, 40 45, 50 1*
MHW2-20D MHW2-25D MHW2-32D MHW2-40D MHW2-50D MHW2-20D MHW2-25D MHW2-32D MHW2-40D MHW2-50D M5 x 0.8 M6 x 1 M6 x 1 M8 x 1.25 M10 x 1.5 M5 x 0.8 M6 x 1 M6 x 1 M8 x 1.25 M10 x 1.5 4.3 7.4 7.4 17.7 37.2 2.9 5.9 5.9 17.7 37.2 10 12 12 16 20 7 10 10 15 20 Model Applicable bolts Max. tightening torque (Nm) Max. screw-in depth (lmm) MHW2-20D MHW2-25D MHW2-32D MHW2-40D MHW2-50D M5 x 0.8 M6 x 1 M6 x
52 25 to 1400 M10 x 1.25 58 38 16 32 15 37 31 3/8 39 141 11 25 16 16 209 22 38 40 12 15 52 52 25 to 1400 M10 x 1.25 65 45 12 32 15 36 30 3/8 42 141 11 25 16 16 209 22 38 1/3.5 stroke 50 15 15 55 52 25 to 1400 M10 x 1.25 76 52 15 40 19 43 35 1/2 46 155 13 31.5 20 20 230 25 45 63 15 20 65 55 25 to 1500 M12 x 1.5 90 63 15 42 19 43 35 1/2 52 163 15 40 31.5 31.5 261 40 63 80 17 20 80
15 20 20 2 pcs. 5 10 15 10 20 15 Auto Switch Mounting Bracket Part Nos.
1 pc. 5 5 10 15 15 20 10 15 2 pcs. 5 10 15 15 20 20 10 Auto Switch Proper Mounting Position (Detection at Stroke End) and Its Mounting Height 20, 25 D-A9V D-M9V D-M9WV D-M9AVL D-A9 D-M9 D-M9W D-M9AL Hs B A 32 to 100 D-A9V D-M9V D-M9WV D-M9AVL B D-A9 D-M9 D-M9W D-M9AL Hs A Auto Switch Proper Mounting Position Auto Switch Mounting Height (mm) (mm) Auto switch model D-M9 D-M9V D-M9W D-M9WV
0.016 0.043 MHZ2-16E 16f8 58.7 10 15 20 D2 0.020 0.053 MHZ2-20E 20f8 70.5 19 22 12 0.020 0.053 D1 MHZ2-25E 25f8 82.9 24 25 15 Other dimensions and specifications correspond to the standard type.
(mm) C D MHZ2-10D-X46 MHZ2-16D-X46 MHZ2-20D-X46 MHZ2-25D-X46 Model A B D9 4.5 11 5.2 7.5 7 13 5.8 2010 7 15 6 10.7 7 20 6.2 Dimensions other than the above are identical to the standard type; refer to pages 12-2-33 to 12-2-36. Reference values to establish criteria for needle adjustment.
(mm) C D MHZ2-10D-X46 MHZ2-16D-X46 MHZ2-20D-X46 MHZ2-25D-X46 Model A B D9 4.5 11 5.2 7.5 7 13 5.8 2010 7 15 6 10.7 7 20 6.2 Dimensions other than the above are identical to the standard type; refer to pages 12-2-33 to 12-2-36. Reference values to establish criteria for needle adjustment.
MHF2-8D 4 0.63 M3 x 0.5 MHF2-12D 5 1.5 M4 x 0.7 MHF2-16D 5.5 3 M5 x 0.8 MHF2-20D 6 5.2 M6 x 1 Holding point is not adjusted.