/D-A96 CD-P12 OUT () Blue Blue D-A96(V) Indicator light DC (+) Brown LED diode D-A90 without indicator light (+) M2.5 x 4l Slotted set screw Resistor Load Reed switch DC power supply OUT Black Reverse current prevention diode diode () DC () Blue Most sensitive position ( ): dimensions for D-A93.

Compact Type: CXSJ Vertical mounting L L Mounting orientation m m Maximum speed (mm/s) up to 600 up to 800 up to 400 up to 200 Stroke (mm) All strokes 6 10 Selection graph 1 2 3 4 Horizontal mounting L Mounting orientation m m Refer to the caution notes below. up to 800 up to 400 up to 800 up to 400 up to 400 up to 800 up to 400 up to 800 up to 50 up to 75 up to 10 up to 30 Stroke (mm) Maximum

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 5 15 Note) 25 Note) 10 10 5 2 10 Note) 25 Note) RQ 5 1 15 Note) Note) Please consult with SMC for shorter stroke length than indicated in the table.

D-A90(V) AC DC AC DC 100V or less 20mA AC DC 24V or less 50mA Maximum load current Contact protection box OUT () Brown [Red] Reed switch Reed switch Reed switch Contact protection circuit Internal voltage drop CD-P11 OUT ( ) Blue [Black] CD-P12 D-A93, A93V, D-A96, A96V (with indicator light) D-A93(V) D-A93 In-line D-A93V Perpendicular D-A96 In-line D-A96V Perpendicular Relay, PLC IC circuit

Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX D-X 20Data Simple guide type allows a workpiece to be mounted directly.

CQ2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Material: Chromium molybdenum steel (Nickel plated) Bore size (mm) RQ T1 M F E D B T2 Part no.

MB-F05 MB-F06 MB-F08 MB-F10 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Single clevis MB-C03 MB-C04 MB-C05 MB-C06 MB-C08 MB-C10 100 1000 Double clevis MB-D03 MB-D04 MB-D05 MB-D06 MB-D08 MB-D10 Note 1) Order two axial foot brackets per cylinder.

Auto switch type Bore size (mm) Bore size (mm) Standard strokes (mm) Model D-A3, D-A4 D-G3, D-K3 D-B5, D-B6 D-G5, D-K5 D-A5, D-A6 D-F5, D-J5 32 25 to 800 32 BT-06 BA-32 40 25 to 800 40 BT-06 BA-04 BD1-04M 50 25 to 800 50 BT-06 BA-05 BD1-05M CH2E 63 25 to 800 63 BT-08 BA-06 BD1-06M 80 25 to 1000 80 BT-16 BA-08 BD1-08M 100 25 to 1000 100 BT-18 BA-10 BD1-10M 32 BT-06 BAF-32 Note) Refer to

47 C 11 21 27 34.5 35.5 44.5 A 19.5 29.5 35.5 43 44 53 6 10 15 20 25 32 Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.

47 C 11 21 27 34.5 35.5 44.5 A 19.5 29.5 35.5 43 44 53 6 10 15 20 25 32 Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.

Speed 600 mm/s Standard Strokes Standard stroke (mm) Maximum manufacturable stroke (mm) Bore size (mm) Symbol 25 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 4000 32 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 40 5000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 High Precision Guide Type REBH Order Made

Operating range 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Intermediate strokes are available. (No spacer is used.)

44.5 A 19.5 29.5 35.5 43 44 53 D 7.5 5 2 5 7 7.5 MY 6 10 15 20 25 32 CY MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com D-A9V D-M9V D-F9WV 5 (7) ( ): Denotes the values of D-M9V, D-F9WV.

B D Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Parallel electrical entry B A A D Reed Switch D-A90(V), D-A93(V), D-A96(V) Reed Switch D-A90(V), D-A93(V), D-A96(V) Set screw (included to auto switch) (mm) Stroke (mm) 20 45 25 51 31 Stroke (mm) 10 34.5 35.5

44.5 A 19.5 29.5 35.5 43 44 53 D 7.5 5 2 5 7 7.5 MY 6 10 15 20 25 32 CY MG CX Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.

25 1200 100, 200, 300, 400, 500, 600, 800, 1000 25 2 axes 1500 32 Note) Contact SMC if the maximum stroke is exceeded.

Load voltage Indicator light Lead wire length (m) AC DC Auto switch model Applicable load Pre-wire connector Special function Type Electrical entry Wiring (Output) 5(Z) 0.5(Nil) 3(L) Perpendicular In-line Reed switch Solid state switch IC circuit 3-wire (NPN equivalent) A96 A96 5 V Grommet Yes Relay, PLC 2-wire A93V A93 100 V 24 V 12 V M9NV M9N 3-wire (NPN) IC circuit 5 V, 12 V M9PV