SMC Corporation of America
Elite Part Number Search
Search Results "D-M9BW-50"

Auto Switch Mounting Heights (mm) D-Y59 D-Y7P D-Y7W D-Y7BA D-Z7 D-Z80 D-M9 D-M9W D-M9A D-A9 D-M9V D-M9WV D-M9AV D-A9V D-Y69 D-Y7PV D-Y7WV Bore size (mm) U 22 24.5 31.5 35.5 40.5 50 60.5 73 U 28 30 34.5 39 45 53.5 64 76.5 U 25.5 27.5 U 31.5 35.5 40.5 50 60.5 73 U 31.5 36 42 50.5 61 73.5 20 25 32 40 50 63 80 100 D-A9/A9V models cannot be mounted on 32 to 100. 287 CHKG Series Auto Switch

Weight (g) Applicable bore size(mm) Weight Applicable bore size(mm) Weight Auto switch model Auto switch model D-A33C-4, A34C-4 D-A33C-5, A34C-5 D-A33C-6, A34C-6 D-A33C-8, A34C-8 D-A33C-10, A34C-10 D-A44C-4 D-A44C-5 D-A44C-6 D-A44C-8 D-A44C-10 162 166 184 210 232 160 164 182 208 230 40 50 63 80 100 40 50 63 80 100 Dimensions (mm) T Applicable bore size (mm) 40 50 63 80 100 C 44 52 64 78 92

Auto switch model Cylinder model Bore size (mm) 100 80 63 50 40 32 D-G39/K39 D-A3/A44 D-G5/K59 D-G5W/K59W D-G5BA/G59F/G5NT D-B5/B64/B59W D-G39/K39 D-A3/A44 D-G5/K59 D-G5W/K59W D-G5BA/G59F/G5NT D-B5/B64/B59W D-G39/K39 D-A3/A44 D-G5/K59 D-G5W/K59W D-G5BA/G59F/G5NT D-B5/B64/B59W BD1-04M BD1-05M BD1-06M BD1-08M BD1-10M [Stainless steel mounting screw kits] CH2E The following

Auto Switch Mounting Height (mm) D-F5 D-J5 D-F59F D-F5W D-J59W D-F5BA D-F5NT Auto switch model D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W D-Y7BA D-A9 D-M9 D-M9W D-M9A D-Y69 D-Y7PV D-Y7WV D-A3 D-G39 D-K39 D-M9V D-M9WV D-M9AV D-A5 D-A6 D-A59W D-A9V D-P4DW D-A44 Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Bore size 32 40 50 63 80 100 125 24.5 23 35 67 27.5 77 27.5 27.5 24.5 25.5 23 32.5 23

For details, refer to page 443. 413 CHA Series How to Mount and Move the Auto Switch Solid state D-F59, D-F5P D-J59, D-F5BA D-F59W, D-F5PW, D-J59W D-F59F, D-F5NT Reed D-A53, D-A54, D-A56, D-A64, D-A67 D-A59W Solid state D-M9N(V), D-M9P(V), D-M9B(V) D-M9NW(V), D-M9PW(V), D-M9BW(V) D-M9NA(V), D-M9PA(V), D-M9BA(V) Auto switch mounting screw

64.5 74.5 U 28 35 38.5 44.5 51 61 71 U 31 38 41.5 47.5 54 64 74 U 27 34 37.5 43.5 50 60 70 20 32 40 50 63 80 100 257 CHQB/CHQWB Series Minimum Auto Switch Mounting Stroke (mm) D-A9 D-A9V D-A7 D-A80 D-A7H D-A80H D-A73C D-A80C D-M9WV D-M9AV D-F7W D-F7WV D-J79W D-F7BAV D-M9W D-M9A D-F7BAL D-F7NT D-F79F D-M9 D-M9V D-F7V D-J79C Auto switch mounting number D-F7 D-J79 D-A79W 1 pc. 5 5 10(5) 10

Operating Range (mm) Auto switch model Bore size (mm) 9.5 9.5 11.5 12 20 32 40 50 63 D-A9(V) 7 9 9.5 D-M9(V) D-M9W(V) D-M9A(V) 2.5 4 6 6 6 6.5 D-A7(H)(C) D-A80(H)(C) 9.5 12 12 11 10 12 D-A79W 11.5 13 13 14 14 16 D-F7(V) D-J79(C) D-F7W(V) D-F7BA(V) D-F7NT D-F79F 4 5.5 6 6 6 6.5 D-X Since the operating range is provided as a guideline including hysteresis, it cannot be guaranteed (assuming

10 11 Relief type Vacuum suction type M9BW Z 60 16 L W 2 J D C 10 B M9BW Z 60 16 L W 2 J D C 21 B Nil Built-in magnet No Nil Auto switch Number of auto switches D With auto switch (Built-in magnet) Nil S n Without auto switch 2 pcs. 1 pc. n pcs.

D-G5NT D-G5lW D-K59W D-G5BA D-G59F D-F5l D-J59 D-F59F D-F5lW D-J59W D-F5BA D-M9l D-M9lV D-M9lW D-M9lWV D-M9lA D-M9lAV D-B5l D-B64 D-A9l D-A9lV D-A59W D-F5NT D-P3DWA D-P4DW Bore size A B A B A B A B A B A B A B A B A B A B A B 40 10 8 6 4 4 1 5.5 3.5 3.5 0.5 0.5 0 1 0 7 4 2.5 0 4.5 1.5 12 9 50 10 8 6 4 3.5 1.5 5.5 3.5 3 1 0 0 0.5 0 6.5 4.5 2 0 4 2 11.5 9.5 63 12.5 11.5 8.5 7.5 6 5 8 7 5.5

position 143 2-Color Indicator Solid State Auto Switch Direct Mounting Type D-M9NW(V)/D-M9PW(V)/D-M9BW(V) RoHS Refer to SMC website for the details of the products conforming to the international standards.

(Red Green Red) D-M9NWV D-M9NW D-M9BW D-M9BWV D-M9PWV D-M9PW Auto switch model In-line Perpendicular In-line Perpendicular In-line Perpendicular Electrical entry direction 3-wire 2-wire Wiring type NPN PNP Output type 24 VDC relay, PLC IC circuit, Relay, PLC Applicable load 5, 12, 24 VDC (4.5 to 28 V) Power supply voltage 10 mA or less Current consumption 24 VDC (10 to 28 VDC) Load voltage

) (n = 2, 3, 4, 5) D-A9mV 5 10 35 10 + 35(n 2) 2 (n = 2, 4, 6) Note 3) 35 + 25 (n 2) (n = 2, 3, 4, 5) Band mounting D-C7m D-C80 10 15 50 15 + 40(n 2) 2 (n = 2, 4, 6) Note 3) 50 + 20 (n 2) (n = 2, 3, 4, 5) D-H7m/H7mW D-H7BA D-H7NF 10 15 60 15 + 45(n 2) 2 (n = 2, 4, 6) Note 3) 60 + 22.5 (n 2) (n = 2, 3, 4, 5) D-C73C D-C80C D-H7C 10 15 65 15 + 50(n 2) 2 (n = 2, 4, 6) Note 3) 50 + 27.5

CJ2-Z Series Air Cylinder/10, 16 10-/1121-/22How to Order Cushion Clean series 10 11 Relief type Vacuum suction type Nil A Rubber bumper (Standard) Air cushion 10 D L 16 60 A R C J 2 M9BW Z B 21 D L 16 60 R C J 2 M9BW Z B Number of auto switches Nil Built-in magnet Head cover port location Nil S n 2 pcs. 1 pc. n pcs.

LAT LEJS40 LEJS63 Applicable auto switches D-M9N(V)-900, D-M9P(V)-900, D-M9B(V)-900 D-M9NW(V)-900, D-M9PW(V)-900, D-M9BW(V)-900 LZ *4 Please consult with SMC for non-standard strokes as they are produced as special orders. LC3F2 * Specifications and dimensions for the 25A-series are the same as standard products.

(n 2) 2 D-C7 D-C80 D-H7C D-C73C D-C80C D-G5/K59 D-G5W/K59W D-G59F/G5BA/G5NT D-B5/B64 50 + 45 (n 2) (n = 2, 3, 4, 5) 10 15 50 D(n = 2, 4, 6) Note 3) 15 + 50 (n 2) 2 65 + 50 (n 2) (n = 2, 3, 4, 5) 10 15 65 15 + 50 (n 2) 2 75 + 55 (n 2) (n = 2, 3, 4, 5) 10 15 75 (n = 2, 4, 6) Note 3) (n = 2, 4, 6) Note 3) 20 + 50 (n 2) 2 75 + 55 (n 2) (n = 2, 3, 4, 5) D-B59W 15 20 Note 3) When n is

45 L 15 50 CQ-M3 x 50 L 20 55 CQ-M3 x 55 L 25 60 CQ-M3 x 60 L 30 65 CQ-M3 x 65 L 35 70 CQ-M3 x 70 L 40 75 CQ-M3 x 75 L 45 80 CQ-M3 x 80 L 50 85 CQ-M3 x 85 L 20 5.5 D C 5 45 CQ-M3 x 45 L 10 50 CQ-M3 x 50 L 15 55 CQ-M3 x 55 L 20 60 CQ-M3 x 60 L 25 65 CQ-M3 x 65 L 30 70 CQ-M3 x 70 L 35 75 CQ-M3 x 75 L 40 80 CQ-M3 x 80 L 45 85 CQ-M3 x 85 L 50 90 CQ-M3 x 90 L 25 8 6 MXZ Series Dimensions: MXZ12

1.25 12 55 45 5H9 5.5 33 5H9 5.5 297 MSZ Series Proper Auto Switch Mounting Position B A Magnet Operating range proper mounting position (Lm/2) Most sensitive position Operating range of single auto switch (Lm) Reed auto switch Solid state auto switch D-M9 (V), D-M9W (V) D-A9, D-A9V Rotation Size Operating angle m Hysterisis angle Operating angle m Hysterisis angle A B A B 10 20 30 50 190

Confirm the Coordinates and Moments in Model Selection on page 1229 for details of floating Y and Z axes. 1196 MY1B Series Auto Switch Mounting Auto Switch Proper Mounting Position (Detection at Stroke End) MY1B (Basic type) 25 to 40 Auto Switch Proper Mounting Position (mm) D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV Auto switch model D-A9 D-A9V A A Bore size A 25 32 40 79 83 112.5 116.5 133.5