SMC Corporation of America
Elite Part Number Search
Search Results "DMK6P-23-C1"

With external pilot specifications (Pitch) P = 10.5 13.5 46.9 18.3 11.8 14.1 8.4 8.6 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 10 19.7 24.6 23 5 3 E 5 3 E 3 5 E 3 5 E 43.2 43 56.5 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 C2 C2 1 P 1 P 1 P 1 P One-touch fitting [1(P), 3/5(E) port] Applicable tubing O.D.: 8 5/16" PE PE X X C1 C1 2 x M12 One-touch fitting [PE: Pilot EXH port] Applicable tubing

Note 10 Description 15 20 30 40 Seal kit P473050-23 A set of above numbers o, !9, @0, @1 and @2 P473010-23 P473020-23 P473030-23 P473040-23 Parts included in Seal Kit DNo. Description Qty. Note 9 4 Wear ring 19 1 Seal 2 Gasket for cover Size: 10, 15 20 1 Gasket for end cover 4 Size: 20, 30, 40 Gasket 21 4 Piston seal 22 2 Seal washer A set includes all parts above.

-A C3SL-23-A C4SL-23-A With level gauge C3LL-38-A C4LL-38-A *1 The bowl assembly comes with a bowl seal.

23 SE1-01-16/-17 I Z I Z SE1-01-16C/-17C Pressure setting trimmer 2 Pressure setting trimmer 1 Pressure setting trimmer 2 Pressure setting trimmer 1 SET1 SET2 L L H H 15 SET1 SET2 L L H H 15 Indicator light (Red, Green) 23 Indicator light (Red, Green) 23 600 (3000) 56.5 600 (3000) 49 8.5 47 47 3.5 3.5 8.5 2-3.5 Mounting hole T1: NPTF 1/8 01: R 1/8 M5 x 0.8 depth 5 Piping port M5 x 0.8 depth

IDX-OM-W035-B / Series IDFB22E-11 IDFB22E-11 K,R,S,T,V IDFB22E-23 IDFB22E-23 K,R,T,V IDFB37E-23 IDFB37E-23 K,R,T,V IDFB55E-46 IDFB55E-46 L,R,T,V IDFB75E-46 IDFB75E-46 L,R,T,V URLhttps://www.smcworld.com/ English instruction manual can be downloaded from our URLhttps://www.smcworld.com/ SMC () * 1 ) JIS B8370 * 2 ) ISO4414 *1) ISO4414Pneumatic fluid power General rules and safety requirements

) EX600-DX#C1 (5 byte) Byte Bit Parameter Setting value 0..3 Unit No. 0..8 0 4..7 Parameter type 1 1 0..7 Unit ID EX600-DX#C1: 0D (Hex) Unit parameter 0 Monitor short circuit (power) 0: disable, 1: enable 1 Reserved 0 2 Inrush current filter 0: disable, 1: enable 2 3 Reserved 0 4..5 Input filtering time 0: 0.1 ms, 1: 1 ms, 2: 10 ms, 3: 20 ms 6..7 Input extension time 0: 1 ms, 1: 15 ms, 2:

[mm] Width across flats B1 Size B1 C1 H1 L1 L2 MM H1 C1 L2 25 22 20.5 8 38 23.5 M14 x 1.5 32 22 20.5 8 42.0 23.5 M14 x 1.5 63 27 26 11 76.4 39 M18 x 1.5 L1 The L1 measurement is when the unit is in the Z-phase first detecting position.

17 M6 x 1.0 10 5 28 23 43.5 Refer to page 11 for details on rod end nut and accessories.

17.5 15 17.5 22 23 23 24 22 23 23 24 Note 2) 2 magnets for auto switches are equipped to the magnet mounting block.

For more information, please refer to page 8-14-23.

E1 = Short shaft side Short shaft side X = Y L4 = L2 = X = C2 Y = C1 = C C2 = C E2 = D1 = E3 = D2 = Long shaft side Long shaft side C1 Y= Depending on the change that has been made, the flat portion of the standard product may remain. Size 20, 30, 40 Size 10, 15 L3 = (mm) L1 = X = Applicable shaft type: W Equal dimensions are indicated by the same marker.

SMC PRESSURE SWITCH B A VJ3233-X17 PRESS. 2.5~7kgf/cm2 SOL.a SOL.b B A RESET SET B A Digital pressure switch PE (76 for D2, D3 types) PD 85 74 PS SMC 65 PV 147 13-3-23 23 Ejector exhaust Series ZR Vacuum pad connection V port Ejector System with Valve Pilot exhaust PE port Vacuum release air supply PD port Circuit diagram Pilot valve air supply PS port Ejector air supply PV port PS PE 1 SOL.c

1.0 10 5 28 23 43.5 Refer to page 7-7-14 for details on rod end nut and accessories.

H B C F A E G J K L D Size Tolerance +0.027 0 +0.027 0 +0.027 0 +0.027 0 +0.033 0 +0.033 0 +0.033 0 40 47 21 45 19 12 9 18 12 32 M8 x 20 60 R15 40 double clevis type 44 L K counter bore depth 2 J counter bore 50 53 23 50 23 12 11 21 14 35 M10 x 22 73 R18 50 double clevis type 53 A B 63 60 27 55 23 15 11 23 16 40 M10 x 25 80 R20 63 double clevis type 60 AC-A1bore size 80 67 31 65 28 16 13

Refer to the dimensions on page 562 for the mounting dimensions. (35) (25) 5.5 1.25 L Dimension [mm] No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 L 23 35.5 48 60.5 73 85.5 98 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5 248 260.5 No. 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 L 273 285.5 298 310.5 323 335.5 348 360.5 373 385.5 398 410.5 423 435.5 448

Switching of the contact input signal 2 23. Press the [] key. Displays screen for setting the operation for the Contact input signal 2. Operation for alarm AL26: Contact input signal 2 detection can be selected. Operation of the contact input signal 2 INP2 ALARM(Alternately displayed) Set value Contents Initial value OFF Alarm is not generated.

H B C F A E G J K L D Tolerance Size 40 double clevis type 50 double clevis type 63 double clevis type 80 double clevis type 100 double clevis type 125 double clevis type 160 double clevis type +0.027 0 +0.027 0 40 M8 x 20 21 60 45 19 12 R 15 9 12 18 32 47 44 L K counter bore depth 2 J counter bore 50 M10 x 22 23 73 50 23 12 R 18 11 14 21 35 53 53 A B +0.027 0 63 M10 x 25 27 80 55 23 15 R

80 100 L1 X C1 H2 Rod end nut Note) Be sure to use the attached flat washers when mounting a cylinder from the rod side.