Max Operating Pressure: 3 (3.5 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 04 [1/2 Threaded, 15 (1/2) Flange SSA], Pressure Indicator: 1 (Differential Pressure Indicator), Relief Valve: 0 (Relief Valve), Fluid: 0 (Petroleum), Element: P (Paper), Filtration: 10μm, Fluid Direction: L (IN Right)
Max Operating Pressure: 3 (3.5 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 04 [1/2 Threaded, 15 (1/2) Flange SSA], Pressure Indicator: 1 (Differential Pressure Indicator), Relief Valve: 0 (Relief Valve), Fluid: 0 (Petroleum), Element: P (Paper), Filtration: 5μm
Max Operating Pressure: 3 (3.5 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 04 [1/2 Threaded, 15 (1/2) Flange SSA], Pressure Indicator: 1 (Differential Pressure Indicator), Relief Valve: 0 (Relief Valve), Fluid: 0 (Petroleum), Element: P (Paper), Filtration: 10μm
Type: -, Type: Line filter, Hydraulic fluid: Petroleum series, Connection Port Size: 1/2B, Nominal filtration(μm): 20, Differential pressure display: Differential pressure indicator, Relief valve: With Relief valve, O-ring nominal size: N/A, Structure / connection method: Screw-in, Operating pressure (max.)(MPa): 7, Element: Paper, Flow Direction: IN left, Made-to-order specifications: None
Type: -, Type: Line filter, Hydraulic fluid: Petroleum series, Connection Port Size: 1/2B, Nominal filtration(μm): 20, Differential pressure display: Differential pressure indicator, Relief valve: With Relief valve, O-ring nominal size: N/A, Structure / connection method: Flange, Operating pressure (max.)(MPa): 21, Element: Paper, Flow Direction: IN left, Made-to-order specifications: None
Max Operating Pressure: 4 (7 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 04 [1/2 Threaded, 15 (1/2) Flange SSA], Pressure Indicator: 1 (Differential Pressure Indicator), Relief Valve: 0 (Relief Valve), Fluid: 0 (Petroleum), Element: P (Paper), Filtration: 20μm
FH series suction filters are compact and lightweight. Designed with an aluminum casted housing. Element can be replaced by simply opening the cover to detach the element without touching the pipes. The filter can be fitted with a differential pressure indicator which senses when the element is becoming dirty, facilitating maintenance and helping to avoid pump damage such as cavitations.
FH series suction filters are compact and lightweight. Designed with an aluminum casted housing. Element can be replaced by simply opening the cover to detach the element without touching the pipes. The filter can be fitted with a differential pressure indicator which senses when the element is becoming dirty, facilitating maintenance and helping to avoid pump damage such as cavitations.
FH series suction filters are compact and lightweight. Designed with an aluminum casted housing. Element can be replaced by simply opening the cover to detach the element without touching the pipes. The filter can be fitted with a differential pressure indicator which senses when the element is becoming dirty, facilitating maintenance and helping to avoid pump damage such as cavitations.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, FILTER, HYDRAULIC, OTHERS, FHG HYDRAULIC FILTER, HX, FHG 1 INCH (MISC./OTHER), 7.51778 lb
Max Operating Pressure: -, Construction: -, Port Size: -, Pressure Indicator: -, Relief Valve: -, Fluid: -, Element: -, Filtration: -, Fluid Direction: -, Made to Order: -
Max Operating Pressure: 3.5 MPa, Construction: Element Upward Removal, Threaded, Port Size: 04 [1/2 Threaded, 15 (1/2) Flange SSA], Pressure Indicator: None, Relief Valve: Relief Valve, Fluid: Petroleum, Element: Paper, Filtration: 5μm, Fluid Direction: -, Made to Order: -
Max Operating Pressure: 3.5 MPa, Construction: Element Upward Removal, Threaded, Port Size: 04 [1/2 Threaded, 15 (1/2) Flange SSA], Pressure Indicator: None, Relief Valve: Relief Valve, Fluid: Petroleum, Element: Paper, Filtration: 10μm, Fluid Direction: -, Made to Order: -
Max Operating Pressure: 3.5 MPa, Construction: Element Upward Removal, Threaded, Port Size: 04 [1/2 Threaded, 15 (1/2) Flange SSA], Pressure Indicator: None, Relief Valve: Relief Valve, Fluid: Water-glycol, Emulsion, Element: Paper, Filtration: 10μm, Fluid Direction: -, Made to Order: -
Max Operating Pressure: 3.5 MPa, Construction: Element Upward Removal, Threaded, Port Size: 04 [1/2 Threaded, 15 (1/2) Flange SSA], Pressure Indicator: None, Relief Valve: None, Fluid: Phosphoric Ester, Element: Paper, Filtration: 5μm, Fluid Direction: -, Made to Order: -
Max Operating Pressure: 3.5 MPa, Construction: Element Upward Removal, Threaded, Port Size: 04 [1/2 Threaded, 15 (1/2) Flange SSA], Pressure Indicator: Differential Pressure Indicator, Relief Valve: None, Fluid: Petroleum, Element: Paper, Filtration: 10μm, Fluid Direction: -, Made to Order: -
Max Operating Pressure: 3.5 MPa, Construction: Element Upward Removal, Threaded, Port Size: 04 [1/2 Threaded, 15 (1/2) Flange SSA], Pressure Indicator: Differential Pressure Indication Switch, Relief Valve: Relief Valve, Fluid: Petroleum, Element: Paper, Filtration: 20μm, Fluid Direction: IN Right, Made to Order: -
Max Operating Pressure: 3.5 MPa, Construction: Element Upward Removal, Threaded, Port Size: 04 [1/2 Threaded, 15 (1/2) Flange SSA], Pressure Indicator: None, Relief Valve: None, Fluid: Phosphoric Ester, Element: Micromesh, Filtration: 40μm, Fluid Direction: IN Left, Made to Order: Non-standard Filtration
Max Operating Pressure: 3.5 MPa, Construction: Element Upward Removal, Threaded, Port Size: 04 [1/2 Threaded, 15 (1/2) Flange SSA], Pressure Indicator: Differential Pressure Indication Switch, Relief Valve: Relief Valve, Fluid: Water-glycol, Emulsion, Element: Paper, Filtration: 10μm, Fluid Direction: -, Made to Order: -
Max Operating Pressure: 3 (3.5 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 04 [1/2 Threaded, 15 (1/2) Flange SSA], Pressure Indicator: 0 (None), Relief Valve: 0 (Relief Valve), Fluid: 0 (Petroleum), Element: P (Paper), Filtration: 5μm