Lead wire length indication Note 1) Applicable auto switch with 5 m lead wire (Z) Reed switch: D-B53/B54, DC73(C)/C80C, D-A73(C)(H)/ A80C, D-A53/A54, D-Z73, D90/97/90A/93A Solid state switch: Manufactured upon receipt of order as standard.
Lead wire length indication Note 1) Applicable auto switch with 5 m lead wire (Z) Reed switch: D-B53/B54, DC73(C)/C80C, D-A73(C)(H)/ A80C, D-A53/A54, D-Z73, D90/97/90A/93A Solid state switch: Manufactured upon receipt of order as standard.
d A IZN10E-01 02m06 6 3.5 IZN10E-01 02m07 1/4" 7 34.7 26 2 x M3 x 0.5 thread depth 10 11 291 *1 Dimension of the resin part in described in the Mounting Warning note 3 (page 24). 18.31 One-touch fitting (Elbow) IZN10E-mm 16 17 D B C Applicable tubing O.D. d 180 [mm] Model d B C D IZN10E-mm16 6 22 16 11.5 IZN10E-mm17 1/4" 24.5 18.5 12 Female threads for piping (Rc1/8) IZN10E-11mm 14 Rc1/
The G46, G46E, G46-L, G46-SRA/B, GZ46, GZ46E, and GP46 can be panel mounted. Dedicated attachments (cover ring assemblies) are required.
When ordering a pressure gauge with an attachment, indicate “-C” (irremovable clear cover with no protrusion) or “-C2” (removable clear cover with protrusion/with protruding wrench flats) in the part number.
Model (Made to Order) Model Pressure rangeNote) Indication unit Connection thread Note MPa G46-2-01 to 02-C/ C1 G46-4-01 to 02-C/ C1 G46-7-01 to 02-C/ C1 G46-10-01 to 02-C/ C1 G46-2-01 to 02M-C/ C1 G46-4-01 to 02M-C/ C1 G46-7-01 to 02M-C/ C1 G46-10-01 to 02M-C/ C1 G46-4-02-X30 G46-10-02-X30 G46-2-02M-X4 G46-4-02M-X4 G46-7-02M-X4 G46-10-02M-X4 G46-2-02M-C/ C1-X4 G46-4-02M-C/ C1-X4 G46-7-02M-C
Type: Pressure Monitor, Sensor, Monitor Structure: Integrated, Output Method: Analog, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [Rc (R)] R, Pressure Resistant(kPa): 100, Operating Temperature Range(°C): 18~28, Response Differential(kPa): ±3, Pipe Connection Direction: Back, Plumbing Thread Nominal: [1/8] 1/8, Rated Pressure Range(kPa): -100 to 0, Compatible Fluid: Air,
Specifications: Oil-free, External parts copper-free, Display Pressure: -100 to 0 kPa, Connection Thread: R 1/4, Option: None, Attachment: Clear Cover w/o Protrusion, is not Removable
Specifications: E (Oil-free, External parts copper-free), Display Pressure: -100 to 0 kPa, Connection Thread: 01 (R 1/8), Option: M (w/M5, Female Thread), Attachment: C (Clear Cover w/o Protrusion, is not Removable)
Specifications: E (Oil-free, External parts copper-free), Display Pressure: -100 to 0 kPa, Connection Thread: 02 (R 1/4), Option: None, Attachment: C (Clear Cover w/o Protrusion, is not Removable)
Specifications: E (Oil-free, External parts copper-free), Display Pressure: -100 to 0 kPa, Connection Thread: 01 (R 1/8), Option: None, Attachment: C (Clear Cover w/o Protrusion, is not Removable)
SMC offers a variety of pressure gauges including general purpose, oil-free/external parts copper-free with limit indicator, clean series and a pressure gauge with a pressure switch. Pressure ranges vary from 0 to 1.5MPa, depending on the selected gauge. Panel mounting is possible.General purpose gauge w/limit indicator , Back or vertical side thread , Indication precision: ±3% F.S. (full
R 1/8 R 1/8 KK13S-01M KK13P-01M R 1/4 R 1/4 -02M -02M R 3/8 R 3/8 -03M -03M R 1/2 R 1/2 -04M -04M Female thread type Female thread type Part no. Port size Part no. Port size Rc 1/4 KK13S-02F Rc 1/4 KK13P-02F Rc 3/8 -03F Rc 3/8 -03F Rc 1/2 -04F Rc 1/2 -04F G1/4 -G02F Barb fitting type Barb fitting type Applicable hose I.D. Part no. Applicable hose I.D.
NBR FKM C S A Note 2) T N V Symbol Number of arranged elements Note 1) Not used with fiber elements.
NBR FKM C S A Note 2) T N V Symbol Number of arranged elements Note 1) Not used with fiber elements.
SMC offers a variety of pressure gauges?including general purpose,?oil-free/external parts copper-free with limit indicator, clean series and a pressure gauge with a pressure switch.? Pressure ranges vary from 0 to 1.5MPa, depending on the selected gauge.? Panel mounting is possible.General purpose gauge w/limit indicator , Back or vertical side thread , Indication precision: ?3% F.S. (full
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, GAUGE, VACUUM SERIES, GZ VACUUM GAUGE, JC, GZ 1/8 PORTED, 0.11 lb
Type: Pressure Monitor, Sensor, Monitor Structure: Integrated, Output Method: Analog, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [Rc (R)] R, Pressure Resistant(kPa): 100, Operating Temperature Range(°C): 18~28, Response Differential(kPa): ±3, Pipe Connection Direction: Back, Plumbing Thread Nominal: [1/4] 1/4, Rated Pressure Range(kPa): -100 to 0, Compatible Fluid: Air,
Specifications: None, Display Pressure: -100 to 0 kPa, Connection Thread: 02 (R 1/4), Option: M (w/M5, Female Thread), Attachment: C (Clear Cover w/o Protrusion, is not Removable)
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Port size Port size With check valve Without check valve With check valve Without check valve KKA3P-01M -02M -03M KKA4P-02M -03M -04M KKA6P-03M -04M -06M KKA7P-04M -06M -10M KKA8P-06M -10M -12M KKA9P-10M -12M -14M KKA3P-01M-1 -02M-1 -03M-1 KKA4P-02M-1 -03M-1 -04M-1 KKA6P-03M-1 -04M-1 -06M-1 KKA3S-01M -02M -03M KKA4S-02M -03M -04M KKA6S-03M -04M -06M KKA7S-04M -06M -10M KKA8S-06M -10M -12M