SMC Corporation of America
Elite Part Number Search
Search Results "HRS018-WN-10-BJMT"

Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: J (Automatic Water Supply Function)

Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: JM (J + M)

Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: M [Applicable to DI Water (Deionized Water) Piping]

Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: MT (M + T)

Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: T (High-pressure Pump)

Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: B (Earth Leakage Breaker)

Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: JT (J + T)

Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BM (B + M)

Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance.  An angled supply port facilitates the supply of circulating fluid, even when units are stacked.  A large digital display provides a clear view of the current and set values.  The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter

Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance.  An angled supply port facilitates the supply of circulating fluid, even when units are stacked.  A large digital display provides a clear view of the current and set values.  The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter

Please contact us for the latest version.sales@ocaire.com, PC BOARD / HRS018-A-10, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb

Please contact us for the latest version.sales@ocaire.com, PC BOARD / HRS018-W-10, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: BJMT (B + J + M + T)

Type: -, Cooling Method: -, Cooling Capacity: 1,700/1,900 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: None

Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set)

Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance.  An angled supply port facilitates the supply of circulating fluid, even when units are stacked.  A large digital display provides a clear view of the current and set values.  The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter

, 3.2 kW, 4.2 kW, 5.1 kW, 5.9 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 200 to 230 VAC, 50/60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018

capacities: 1.3 kW, 1.7 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 100 VAC, 50/60Hz or 115 VAC, 60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018

, 3.2 kW, 4.2 kW, 5.1 kW, 5.9 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 200 to 230 VAC, 50/60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018

capacities: 1.3 kW, 1.7 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 100 VAC, 50/60Hz or 115 VAC, 60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018