SMC Corporation of America
Elite Part Number Search
Search Results "HRS050-A-20-V-R"

Cooling Capacity: 050 [Cooling Capacity: 4500/5000 W (50/60 Hz)], Pipe Thread: N (NPT with PT-NPT Conversion Fitting Set), Option: None

Cooling Capacity: 050 [Cooling Capacity: 4500/5000 W (50/60 Hz)], Pipe Thread: NPT with PT-NPT Conversion Fitting Set, Option: None

Cooling Capacity: Cooling Capacity: 4700/5100W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: Rc, Option: J + M

Type: Thermo-Chiller, Cooling Method: Air-Cooling, Cooling Capacity: 4,700/5,100 W (50/60 Hz), Piping thread type: Rc, Optional specifications: With earth leakage circuit breaker

Type: -, Cooling Method: -, Cooling Capacity: 4,700/5,100 W (50/60 Hz), Piping thread type: Rc, Optional specifications: With earth leakage circuit breaker / With automatic water supply

Type: -, Cooling Method: -, Cooling Capacity: 4,700/5,100 W (50/60 Hz), Piping thread type: Rc, Optional specifications: With earth leakage circuit breaker / With automatic water supply / Compatible with deionized water (pure water) piping

Type: Thermo-Chiller, Cooling Method: Air-Cooling, Cooling Capacity: 4,700/5,100 W (50/60 Hz), Piping thread type: Rc, Optional specifications: With earth leakage circuit breaker / Compatible with deionized water (pure water) piping

Type: -, Cooling Method: -, Cooling Capacity: 4,700/5,100 W (50/60 Hz), Piping thread type: Rc, Optional specifications: With automatic water supply

Type: -, Cooling Method: -, Cooling Capacity: 4,700/5,100 W (50/60 Hz), Piping thread type: Rc, Optional specifications: Compatible with deionized water (pure water) piping

Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: BJM (B + J + M)

Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: BM (B + M)

Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: JM (J + M)

Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: B (Earth Leakage Breaker)

Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: J (Automatic Water Supply Function)

Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: BJ (B + J)

Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: M [Applicable to DI Water (Deionized Water) Piping]

A large digital display provides a clear view of the current and set values. 


Alarm code “AL28” (pump maintenance) will be activated every 20,000 hours (every 8000 hours for option “T” and the HRS050/060) of operation.
Consider requesting maintenance from a maintenance company.
We can recommend service providers if needed.

As a guide, it should be replaced after 6000 to 8000 hours of operation.
For the HRS012/018/024/030 option “T” (high-pressure pump) and the HRS050/060, after 8000 hours, alarm code “AL28” (pump maintenance) will be activated.
We recommend that you check for leaks and replace the mechanical seal at this time. Consider requesting maintenance from a maintenance company.

If the external piping resistance is too large, consider installing a bypass piping set. If a bypass piping set has already been installed and there is a valve, open it according to the situation and use it safely while relieving the circulating fluid discharge pressure.