-A-20-JM-X133 Rev 2.0, CHILLER, 729, 20 lb
filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, PUMP FOR CHILLER HRS050-A-20-M, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING,
AMP BREAKER FOR HRS050, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, 2.23666 lb
-A-20-JM-X035), CHILLER, 729, 11 lb
Type: -, Cooling Method: -, Cooling Capacity: 4,700/5,100 W (50/60 Hz), Piping thread type: Rc, Optional specifications: None
Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc
Cooling Capacity: Cooling Capacity: 4700/5100W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: Rc, Option: B + J
Type: -, Cooling Method: -, Cooling Capacity: 4,700/5,100 W (50/60 Hz), Piping thread type: Rc, Optional specifications: With earth leakage circuit breaker
Type: -, Cooling Method: -, Cooling Capacity: 4,700/5,100 W (50/60 Hz), Piping thread type: Rc, Optional specifications: With earth leakage circuit breaker / Compatible with deionized water (pure water) piping
Type: -, Cooling Method: -, Cooling Capacity: 4,700/5,100 W (50/60 Hz), Piping thread type: Rc, Optional specifications: Compatible with deionized water (pure water) piping
Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc, Option: BJ (B + J)
Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc, Option: BM (B + M)
Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc, Option: B (Earth Leakage Breaker)
Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc, Option: M [Applicable to DI Water (Deionized Water) Piping]
Temperature stability: ±0.1°C; Power supply requirement: single phase 200 to 230 VAC, 50/60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018, HRS024, HRS030; SMC recommends Bypass Piping Set HRS-BP004 for Models HRS-040, HRS050
Temperature stability: ±0.1°C; Power supply requirement: single phase 200 to 230 VAC, 50/60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018, HRS024, HRS030; SMC recommends Bypass Piping Set HRS-BP004 for Models HRS-040, HRS050
Alarm code “AL28” (pump maintenance) will be activated every 20,000 hours (every 8000 hours for option “T” and the HRS050/060) of operation.
Consider requesting maintenance from a maintenance company.
We can recommend service providers if needed.
For the HRS012/018/024/030 option “T” (high-pressure pump) and the HRS050/060, after 8000 hours, alarm code “AL28” (pump maintenance) will be activated.
We recommend that you check for leaks and replace the mechanical seal at this time. Consider requesting maintenance from a maintenance company. We can recommend service providers if needed.
Note 1) These are the default settings of the HRS050. The operating settings can be changed by the user.
The default setting for alarm code “AL08” is stop operation for the HRS090 to 200.
of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, Heat exchanger(For option M), HRS050