SMC Corporation of America
Elite Part Number Search
Search Results "HRS050-WN-20-BJM"

0 5 10 15 20 25 Circulating fluid flow rate [L/min] Circulating fluid flow rate [L/min] HRR050-A-20, HRR050-W-20 0.5 Circulating fluid pressure [MPa] Outlet: 60 Hz 0.4 0.3 Outlet: 50 Hz Return port Return port (Option Z) 0.2 Allowable operating range 0.1 0 0 10 20 30 40 Circulating fluid flow rate [L/min] Required Facility Water Flow Rate 012 018 024 030 HRR -W HRR010-W-20 30 20 Facility

Cooling Capacity: Cooling Capacity: 4700/5100W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: B + M

Type: -, Cooling Method: -, Cooling Capacity: 4,700/5,100 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: With earth leakage circuit breaker

Type: -, Cooling Method: -, Cooling Capacity: 4,700/5,100 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: With earth leakage circuit breaker / With automatic water supply

Type: -, Cooling Method: -, Cooling Capacity: 4,700/5,100 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: With automatic water supply

Type: -, Cooling Method: -, Cooling Capacity: 4,700/5,100 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: With automatic water supply / Compatible with deionized water (pure water) piping

Type: -, Cooling Method: -, Cooling Capacity: 4,700/5,100 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: Compatible with deionized water (pure water) piping

Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: B (Earth Leakage Breaker)

Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BJ (B + J)

Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BM (B + M)

Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: J (Automatic Water Supply Function)

Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: JM (J + M)

Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: M [Applicable to DI Water (Deionized Water) Piping]

Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance.  An angled supply port facilitates the supply of circulating fluid, even when units are stacked.  A large digital display provides a clear view of the current and set values.  The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: BJM (B + J + M)

filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, PUMP FOR CHILLER HRS050-A-20-M, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING,

AMP BREAKER FOR HRS050, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, 2.23666 lb

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 20 (3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz), Option: BJM (w/ Earth Leakage Breaker + w/ Automatic Fluid Fill Function + Applicable to Deionized Water Piping)