Cooling Capacity: 100, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: AK (A + K)
Cooling Capacity: 100, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: A (w/Caster Adjuster-foot)
Cooling Capacity: 100, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: AK (A + K), UL Certification: None, Option 2: W (SI Unit Only)
Cooling Capacity: 100, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: A + K, UL Certification: -, Option 2: -
Cooling Capacity: 100, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: w/Caster Adjuster-foot, UL Certification: -, Option 2: -
Cooling Capacity: 100, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: A + K, UL Certification: None, Option 2: SI Unit Only
Cooling Capacity: 100, Thread Type: Rc, Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: K (w/Fluid Fill Port)
K E When ordering an oversized rod, please order the following way to represent the rod size required.
/Flange Rod end width across flats 10 10 21 21 46 46 Data Part no.
with an are the same as standard.
75 3/4 18 28 190 27 44 122 (mm) Rod series B-series rod C-series rod Bore size (mm) MM A MA D E MM K G H ZZ A MA D E K G H ZZ 32 M16 x 1.5 25 22 18 7 14 66 268 34 -0.025 -0.064 40 M16 x 1.5 25 22 18 7 14 66 268 36 M20 x 1.5 30 27 22.4 9 19 71 278 40 -0.025 -0.064 50 M20 x 1.5 30 27 22.4 9 19 73 296 40 M24 x 1.5 35 32 28 11 24 78 306 46 63 M24 x 1.5 35 32 28 11 24 85 326 46 M30
Manifold Option JIS symbol Blanking plate assembly VVCW 1486 3A 2 K Series Material 2 3 4 Class 2 Class 3 Class 4 Plate material Seal material PTFE FKM Symbol K H Stainless steel This is used by mounting it on the manifold block when a valve is removed for maintenance or when the mounting of an additional valve is planned, etc. 17-2-46 9 Series VCS Direct Operated 2 Port Solenoid Valve For
Note 1) This cylinder cannot perform an intermediate stop using an air pressure circuit in vertical operation. In this case, an intermediate stop can be performed only by using an external stopper, etc. Made-to-order products should be considered, too, depending on an operating environment, etc.
14 8 20 30 16.5 19.5 12.5 66 44 20 77 10.5 7 75, 100 165 46 Bore size K L M O P Q R RR RR1 U1 W Z A1 A2 B1 C1 H1 L1 MM X 32 14 46 34 M6 x 1.0 1/8 10 10 10 12 14 49.5 14 16 42 22 20.5 8 28.5 M14 x 1.5 23.5 40 14 46 40 M6 x 1.0 1/8 12.5 10 10 12 14 57 15 16 42 22 20.5 8 28.5 M14 x 1.5 23.5 50 17 59 50 M8 x 1.25 1/4 10.5 14 14 16 20 71 19 20 56 27 26 11 33.5 M18 x 1.5 28.5 63 17 59 60 M10 x
After tightening by hand, the barb fitting type should be tightened by an additional 1/4 rotation using an appropriate wrench. 2. After tightening by hand, the barb elbow type should be tightened by an additional 1/2 rotation using an appropriate wrench. 2) M5 1. After tightening by hand, the barb fitting type should be tightened by an additional 1/6 rotation using a suitable tool. 2.
Note 3) ZP3-(015/02/035)U ZP3-Y(015/02/035)U;(J/K)3-@ ZP3-Y(015/02/035)U;(J/K)6-@ ZP3B-Y1(J/K)3-B3 ZP3B-Y1(J/K)6-B3 ZP3-Y(10/13/16)UM;(J/K)3-@ ZP3-Y(10/13/16)B;(J/K)3-@ ZP3-Y(10/13/16)UM;(J/K)6-@ ZP3-Y(10/13/16)B;(J/K)6-@ ZP3-Y(10/13/16)UM;(J/K)10-@ ZP3-Y(10/13/16)B;(J/K)10-@ ZP3-Y(10/13/16)UM;(JB/K)15-@ ZP3-Y(10/13/16)B;(JB/K)15-@ ZP3-Y(10/13/16)UM;(JB/K)20-@ ZP3-Y(10/13/16)B;(JB/K)20-@
Note 3) ZP3-(015/02/035)U ZP3-Y(015/02/035)U;(J/K)3-@ ZP3-Y(015/02/035)U;(J/K)6-@ ZP3B-Y1(J/K)3-B3 ZP3B-Y1(J/K)6-B3 ZP3-Y(10/13/16)UM;(J/K)3-@ ZP3-Y(10/13/16)B;(J/K)3-@ ZP3-Y(10/13/16)UM;(J/K)6-@ ZP3-Y(10/13/16)B;(J/K)6-@ ZP3-Y(10/13/16)UM;(J/K)10-@ ZP3-Y(10/13/16)B;(J/K)10-@ ZP3-Y(10/13/16)UM;(JB/K)15-@ ZP3-Y(10/13/16)B;(JB/K)15-@ ZP3-Y(10/13/16)UM;(JB/K)20-@ ZP3-Y(10/13/16)B;(JB/K)20-@
(mm) Without auto switch With auto switch Bore size (mm) Stroke range (mm) C D E F H I J K L M N P Q S O A B B 36 46 43.5 53.5 53 63 A 44 54 53.5 63.5 65 75 10 to 50 75, 100 10 to 50 75, 100 10 to 50 75, 100 63 54 46 15 20 77 10.5 103 7 17 8 60 9 14 depth 10.5 1/4 15 93 M10 x 1.5 80 63.5 53.5 21 25 98 12.5 132 6 22 10 77 112.5 11 17.5 depth 13.5 3/8 16 M16 x 2.0 100 75 63 27 30 117 13 156
Without auto switch With auto switch Bore size (mm) Stroke range (mm) C D E F H I J K M N Q S L P O B A 44 54 53.5 63.5 65 75 B 36 46 43.5 53.5 53 63 A 10 to 50 75, 100 10 to 50 75, 100 10 to 50 75, 100 63 46 15 20 77 10.5 54 M10 x 1.5 14 depth 10.5 93 103 7 17 60 9 15 8 Rc 1/4 80 53.5 21 25 98 12.5 63.5 M16 x 2.0 17.5 depth 13.5 112.5 132 6 22 77 11 16 10 Rc 3/8 100 63 27 30 117 13 75 M20
If an intermediate stop is performed by an external stopper, be careful of ejection when restarting. If lurching occurs, damage can result. If a slide table is stopped at an intermediate position by an external stopper and then moved forwards, after the slide table is returned to the back to retract the stopper, supply pressure to the opposite port to operate the slide table. 3.