Connect the remote control cable and the switch to the connector for the contact input/output, supplied as an accessory. Then, mount the ferrite core (3 turn) supplied as an accessory. (See below) (This is an example of wiring. Refer to the Operation Manual for communication for details.)

Do not use the cylinder under the following environments: An area in which fluids such as cutting oil splash on the piston rod An area in which foreign matter such as particles, cutting chips, or dust is present An area in which the ambient temperature exceeds the operating range An area exposed to direct sunlight An environment that poses the risk of corrosion 2.

, making it possible to hold a cylinder intermediate stopping position for an extended time.

Features Power Consumption Comparison Energy saving Type Conventional type An energy saving type thermo-chiller is added to the conventional series INR-499.

Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: Option Combination D+K

Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, with Rc-NPT Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: A (w/Caster Adjuster foot)

Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, with Rc-NPT Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: Option Combination A+K

Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, with Rc-NPT Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: K (w/Fluid Fill Port)

Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, with Rc-NPT Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: M (Applicable to Deionized Water Piping)

Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, with Rc-NPT Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: Option Combination A+D+K

Cooling Capacity: 38 kW, Cooling Method: Air-cooled Refrigeration, Pipe Thread: NPT, with Rc-NPT Conversion Fitting, Power Supply: 50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC, Option: w/Fluid Fill Port

Cooling Capacity: 38 kW, Cooling Method: Air-cooled Refrigeration, Pipe Thread: NPT, with Rc-NPT Conversion Fitting, Power Supply: 50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC, Option: Applicable to Deionized Water Piping

Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, with Rc-NPT Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: Option Combination A+K+M

Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, with Rc-NPT Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: Option Combination A+D+K+M

Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof. (3) Connecting the wireless unit. After connecting the required I/O units, connect the wireless unit.

Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof. (3) Connecting the wireless unit. After connecting the required I/O units, connect the wireless unit.

Install an air dryer, aftercooler, etc. Excessive condensate in a compressed air system may cause valves and other pneumatic equipment to malfunction. Installation of an air dryer, after cooler etc. is recommended. 3. Drain flushing If condensate in the drain bowl is not emptied on a regular basis, the bowl will over flow and allow the condensate to enter the compressed air lines.

Please refer to the catalogue to confirm the sizes of the fittings to be used. n: Number of stations (mm) Dimensions 5 6 1 26 52 2 36 52 3 46 62 4 56 72 5 66 82 6 76 92 7 86 102 8 96 112 n L1 L2 EXH EXH P PE P PE V V V V Circuit ZQ13M-K1-D ZQ13M-K2-DK ZQ13M-J1-F ZQ13M-Q1-FK 9 Series ZQ Manifold Exploded View 6 3 6 4 6 b b view 4 6 2 a 5 a 5 5 Component Parts No.

Please refer to the catalogue to confirm the sizes of the fittings to be used. n: Number of stations (mm) 5 6 1 26 52 2 36 52 3 46 62 4 56 72 5 66 82 6 76 92 7 86 102 8 96 112 n L1 L2 EXH EXH P PE P PE V V V V Circuit ZQ13M-K1-D ZQ13M-K2-DK ZQ13M-J1-F ZQ13M-Q1-FK 13-9-9 10 Series ZQ Manifold Exploded View 6 3 6 4 6 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA

An angled supply port facilitates the supply of circulating fluid, even when units are stacked.  A large digital display provides a clear view of the current and set values.