Cooling Method: Water-cooled Refrigeration, Pipe Thread: G, w/Rc-G Conversion Fitting, Power Supply: 3-phase 380 to 415 VAC, 50/60 Hz; 3-phase 460 to 480 VAC (60 Hz), Option: Applicable to Deionized Water Piping

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 40 (3-phase 380 to 415 VAC, 50/60 Hz; 3-phase 460 to 480 VAC (60 Hz)), Option: M (Applicable to Deionized Water Piping)

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 40 (3-phase 380 to 415 VAC, 50/60 Hz; 3-phase 460 to 480 VAC (60 Hz)), Option: M (Applicable to Deionized Water Piping)

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: F (G, w/Rc-G Conversion Fitting), Power Supply: 40 (3-phase 380 to 415 VAC, 50/60 Hz; 3-phase 460 to 480 VAC (60 Hz)), Option: M (Applicable to Deionized Water Piping)

Inverter compressor, fan, and pump for efficient power consumption ; Cooling capacity: 9.5kW (Air), 11kW (Water) ; Temperature range setting: 5 to 40° C ; Temperature stability: ±0.1° C ; Standards: CE (400V only), RoHS ; Circulating fluid: Tap water, deionized water, or 15% ethylene glycol solution

Inverter compressor, fan, and pump for efficient power consumption ; Cooling capacity: 9.5kW (Air), 11kW (Water) ; Temperature range setting: 5 to 40° C ; Temperature stability: ±0.1° C ; Standards: CE (400V only), RoHS ; Circulating fluid: Tap water, deionized water, or 15% ethylene glycol solution

Please contact us for the latest version.sales@ocaire.com, MAIN BOARD HRSH090-A-40, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, 2.23666 lb

Please contact us for the latest version.sales@ocaire.com, MAIN BOARD HRSH090-W-40, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, 2.23666 lb

Cooling Method: Air-cooled Refrigeration, Pipe Thread: G, w/Rc-G Conversion Fitting, Power Supply: 3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz, Option: -

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F (G, w/Rc-G Conversion Fitting), Power Supply: 20 (3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz)

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: M (Applicable to Deionized Water Piping)

Cooling Method: Air-cooled Refrigeration, Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: Applicable to Deionized Water Piping

[AF] 0.1 MPa Set pressure range [AR] 0.05 to 0.85 MPa Nominal filtration rating*3 [AF] 5 m Compressed air purity class*4 ISO 8573-1:2010 [ 6 : 4 : ]*5 Drain capacity [AF] 8 cm3 25 cm3 45 cm3 Port size 1/4: 30 L/min (ANR) Port size 3/8: 40 L/min (ANR) Port size 1/2: 50 L/min (ANR) Port size 1/4: 30 L/min (ANR) Port size 3/8: 40 L/min (ANR) Min. dripping flow rate*6 [AL] 15 L/min (ANR) 50

60C (with no freezing) Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa Set pressure range [AR] 0.05 to 0.85 MPa Nominal filtration rating [AF/AFM] AF: 5 m, AFM: 0.3 m (99.9% filtered particle size) Rated flow [L/min(ANR)] [AFM] 3 200 450 450 1100 1100 Outlet side oil mist concentration [AFM] 4 5 Max.1.0 mg/m3 (ANR) (0.8 ppm) Bowl material [AF/AFM] Polycarbonate Bowl guard [AF/AFM

HRX-OM-R028 1st edition: Dec. 2013 Rev.A: Apr. 2013 Operation Manual Communication function Thermo chiller HRSH090 Series Keep this manual available whenever necessary 2013 SMC CORPORATION All Rights Reserved To the users Thank you for purchasing SMCs Thermo chiller (hereinafter referred to as the product).

the grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, O-Ring Set (12-90, HRSH090

Please contact us for the latest version.sales@ocaire.com, MAIN BOARD HRSH090-W-20, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, 2.23666 lb

with the grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, Cooling Fan For HRSH090

with the grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, Cooling Fan For HRSH090