SMC Corporation of America
Elite Part Number Search
Search Results "HRZ008-L-FN"

Model determination 2 Sine Rodless Cylinder Series REA Model Selection Method 2 Precautions on Design 1 Selection Method 40 32 25 500 500 300 200 300 400 Recommended driving force: Fn(N) 200 300 Recommended driving force: Fn(N) Recommended driving force: Fn(N) 200 100 100 100 50 40 20 30 40 50 20 30 40 50 20 30 Usable

Problem 6 Red ON OFF L RUN L RUN LED is OFF OFF Problem 7 L ERR L ERR LED is RED Red ON Problem 8 Problems related to the NFC Problem 9 -61No.EX-OMZ0016-C Base troubleshooting LED status Problem LED Possible causes Investigation and countermeasures Colour of LED ON/Flashing No. name 1 All OFF The US1 (for control) power supply is OFF Supply 24 VDC +/-10% for US1 (for control) power source

J H B A G A mm A B C D E Fn G H J XLC-16 40 110 38 1 30 17 40 26 XLC-25 50 120 48 1 12 40 26 39 27.5 XLC-40 65 171 66 2 11 55 41 63 36 9 XL-OMV0002 4-2.162580,100,160 C E D C E E (KF ) (K ) Fn Fd J K H B A G A mm A B C D E Fn Fd G H J K XLC-50 70 183 80 31 10.5 75 52 77 29 10.5 XLC-63 88 209 100 39 11 87 95 70 76.5 36 9 XLC-80 90 250 117 45.5 11 114 110 83 105 44 9 XLC-100 108 317.5 154

No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Tank Cover L for HRZ008-L(1)-F, REFRIGERATED THERMO-COOLER,

Auto Drain The Japan Refrigeration and Air Conditioning Industry Association JRA GL-02-1994 Cooling water system Circulation type Circulating water Caution Unit [S/cm] [mg/L] [mg/L] [mg/L] [mg/L] [mg/L] [mg/L] [mg/L] [mg/L] [mg/L] [mg/L] [mg/L] [mg/L] Item pH (at 25C ) Electrical conductivity (25C ) Chloride ion (Cl) Sulfuric acid ion (SO42) Standard value

50 or less Sulfuric acid ion (SO42) [mg/L] 50 or less p p p p p Acid consumption amount (at pH4.8) [mg/L] 50 or less Total hardness [mg/L] 70 or less [mg/L] 50 or less Calcium hardness (CaCO3) Ionic state silica (SiO2) [mg/L] 30 or less p p p p p p [mg/L] 0.3 or less Iron (Fe) Copper (Cu) [mg/L] 0.1 or less Should not be detected.

No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, TOP PANEL FOR HRZ008-L/L1, OTHERS, HRZ- THERMO CHILLER, 21

No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, REAR PANEL FOR HRZ008-L/L1, OTHERS, HRZ- THERMO CHILLER, 21

No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, RIGHT PANEL FOR HRZ008-L/L1, OTHERS, HRZ- THERMO CHILLER,

No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, LEFT PANEL FOR HRZ008-L/L1, OTHERS, HRZ- THERMO CHILLER, 21

No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, PACKING MTRL SET HRZ008-L*, REFRIGERATED THERMO-COOLER, 737

No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Compressor Set (HRZ008-L/L1), REFRIGERATED THERMO-COOLER, 737

No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Tank Assembly for HRZ008-L(1)-F, REFRIGERATED THERMO-COOLER,

No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Condenser Assy for HRZ008-L(1), REFRIGERATED THERMO-COOLER,

No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Circulating Pump for HRZ008-L-F, REFRIGERATED THERMO-COOLER,

No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Circuit Protector for HRZ008-L(1)-F, REFRIGERATED THERMO-COOLER

No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Motor Breaker for HRZ008-L(1)-F, REFRIGERATED THERMO-COOLER,

No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Motor Breaker Assy for HRZ008-L(1)-F, REFRIGERATED THERMO-COOLER

No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Magnetic Contactor for HRZ008-L(1)-F, REFRIGERATED THERMO-COOLER

No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Magnetic Contactor for HRZ008-L(1)-F, REFRIGERATED THERMO-COOLER